• Title/Summary/Keyword: 유동효율

Search Result 1,448, Processing Time 0.027 seconds

Effects of Dietary Supplementation of Yeast Pichia farinosa on Performance, Intestinal Microflora, and Fecal $NH_{3}$ Emission in Laying Hens (효모 Pichia farinosa의 첨가 급여가 산란계의 생산능력, 장내미생물 변화 및 분의 암모니아 발생량에 미치는 영향)

  • 김상호;박수영;유동조;이상진;최철환;성창근;류경선
    • Korean Journal of Poultry Science
    • /
    • v.29 no.3
    • /
    • pp.205-211
    • /
    • 2002
  • A feeding trial was conducted to study the effects of a live yeast, Pichia farinosa culture(PF), on the production performance and intestinal microflora in laying hens. One hundred and sixty ISA Brown layers, 21 weeks of age, were randomly allotted to four dietary treatments, with four replicates per treatment. Dietary treatments consisted of four levels (0, 0.1, 0.3, and 0.5%) of PF added to a com-soybean meal based diet. Egg production, egg weight, feed intake and fred conversion ratio(FCR) were measured. Egg qualifies were examined at 25th and 29th weeks of age. A metabolism trial was conducted following the feeding trial, during which intestinal microflora, nutrient digestibility and fecal NH3 gas emission were measured. Egg production of birds fed 0.1 and 0.3% PF were significantly higher than those from birds fed 0 and 0.5% PF(P<0.05). Daily egg mass of 0.3% PF increased significantly compared to that of 0% PF. There was no difference in egg weight among all treatments. Feed conversion ratio was significantly improved as the PF level increased. No significant difference was found in eggshell quality and Haugh unit at both 25 and 29 weeks of age. Viable count of ileal Lactobacillus spp. increased significantly as the rf level increased. However, the total number of yeast and anaerobes in ileum were similar among all treatments. Cecal Lactobacillus spp. and yeast counts showed no difference among all treatments. Fecal NH$_{3}$ gas emission of layers fed PF decreased significantly by the PF supplementation. From the result of this experiment, it could be concluded that dietary supplementation of the live yeast Pichia farinosa improves the laying performance and decreases the fecal ammonia gas emission.

Effects of Dietary Levels of Corn Distiller's Dried Grains with Solubles and Phytase on Performance and Nutrient Utilization of Broilers (옥수수 주정박의 수준과 Phytase의 첨가 유무가 육계의 생산성과 영양소 이용률에 미치는 영향)

  • Hong, E.C.;Na, S.H.;Yu, D.C.;Kim, H.K.;Park, M.N.;Jung, K.C.;Choo, H.J.;Park, H.D.;Chung, W.T.;HwangBo, J.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.3
    • /
    • pp.247-255
    • /
    • 2009
  • This work was conducted to investigate the effects of the addition level of Corn distiller's dried grains with solubles (CDDGS) and phytase in broiler diets on the broiler performance and the ileal amino acid digestibility. Three eighty four Ross broiler (one-day-old) were assigned randomly to 8 treatments groups (12 birds/pen, 4 pens/treatment) as $4{\times}2$ complex factors of CDDGS 4 treatments (0, 5, 10 and 15%) and phytase 2 treatments (0, 500 FTU/kg), and fed experimental diets for 6 weeks (starter, 0~2 wk; grower, 2~4 wk; finisher, 4~6 wk). After the feeding trial was finished, 12 broilers (6 weeks) with similar weights were selected from all treatments to investigate the digestibility of nutrients and amino acids for the first week. The experimental diets contained similar ME and CP of all treatments. Body weight gains and feed intakes were high at phytase treatments (P>0.05), but there was no difference in feed intake of the chicks. The amino acid digestibilities of diets were improved for iso-leucine, lysine, threonine, valine, aspartic acid, proline, serine and tyrosine (P<0.05). Finally, this work showed that growth performance and amino acid digestibility were improved by the addition of CDDGS and phytase in broiler diets.

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF

Evaluation of Design and Operation Parameters for a Spherical Sulfur Denitrification Reactor Treating High Strength Municipal Wastewater (고농도 도시하수 처리를 위한 입상황 탈질 반응조의 설계 및 운영인자 평가)

  • Kim, Yong-Hak;Chae, Kyu-Jung;Yim, Seong-Keun;Lee, Young-Man;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1087-1093
    • /
    • 2010
  • Autotrophic denitrification is known as an effective and economical alternative for heterotrophic denitrification using external carbon sources such as methanol. In this study, we evaluated design and operation parameters for a sulfur denitrification reactor (SDR) treating high strength nitrogen wastewater. The SDR was filled with spherical sulfur media in connected to a pilot-scale nutrient removal process (daily flow rate, $Q=18\;m^3/d$) using moving spongy media. Total nitrogen (TN) concentration of the final effluent was below the 7.0 mg TN/L because nitrate was additionally removed through autotrophic denitrificationin without adding alkalinity (initial alkalinity was $169.4{\pm}20.8\;mg$ $CaCO_3$/L). During the test period, 60~80% of nitrogen in the influent was removed even in low temperature (below $15^{\circ}C$). The alkalinity consumption for nitrate removal in SDR was $4.09{\pm}1.29$ g $CaCO_3/g$ ${NO_3}^-$-N, and the residual alkalinity of influent of SDR was higher than that of theoretical requirements for full conversion of nitrate. The consumption of sulfur was 943.8 g S/d and it was 2.4 times higher than theoretical value (400.1 g S/d) due to abrasion and loss of sulfur media in backwash, etc.

Estimation of $CO_2$ saturation from time-lapse $CO_2$ well logging in an onshore aquifer, Nagaoka, Japan (일본 Nagaoka 육상 대수층에서 시간차 $CO_2$ 물리검층으로부터 $CO_2$ 포화도의 추정)

  • Xue, Ziqiu;Tanase, Daiji;Watanabe, Jiro
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.19-29
    • /
    • 2006
  • The first Japanese pilot-scale $CO_2$ sequestration project has been undertaken in an onshore saline aquifer, near Nagaoka in Niigata prefecture, and time-lapse well logs were carried out in observation wells to detect the arrival of injected $CO_2$ and to evaluate $CO_2$ saturation in the reservoir. $CO_2$ was injected into a thin permeable zone at the depth of 1110m at a rate of 20-40 tonnes per day. The total amount of injected $CO_2$ was 10400 tonnes, during the injection period from July 2003 to January 2005. The pilot-scale demonstration allowed an improved understanding of the $CO_2$ movement in a porous sandstone reservoir, by conducting time-lapse geophysical well logs at three observation wells. Comparison between neutron well logging before and after the insertion of fibreglass casing in observation well OB-2 showed good agreement within the target formation, and the higher concentration of shale volume in the reservoir results in a bigger difference between the two well logging results. $CO_2$ breakthrough was identified by induction, sonic, and neutron logs. By sonic logging, we confirmed P-wave velocity reduction that agreed fairly well with a laboratory measurement on drilled core samples from the Nagaoka site. We successfully matched the history changes of sonic P-wave velocity and estimated $CO_2$ saturation a(ter breakthrough in two observation wells out of three. The sonic-velocity history matching result suggested that the sweep efficiency was about 40%. Small effects of $CO_2$ saturation on resistivity resulted in small changes in induction logs when the reservoir was partially saturated. We also found that $CO_2$ saturation in the $CO_2$-bearing zone responded to suspension of $CO_2$ injection.

Selection of Insecticide Resistance Markers in Field-collected Populations of Myzus persicae (복숭아혹진딧물 야외개체군의 살충제 저항성 마커 선발)

  • Kim, Ju Il;Kwon, Min;Shim, Jae Dong;Kim, Jeom Soon;Lee, Yeong Gyu;Jee, Sam Nyu;Lee, Jeong Tae;Ryu, Jong Soo;Yoo, Dong Lim;Lee, Gye Jun
    • Korean journal of applied entomology
    • /
    • v.53 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • The resistance levels of the green peach aphid, Myzus persicae (Sulzer), against 10 insecticides was checked and selected the applicable insecticide resistance markers. We conducted our study in 5 cabbage cultivation regions (Pyeongchang, Hongcheon, Bongwha, Muju, and Jeju) of Korea, over 3 successive years (2009-2011). We selected a multi-resistant (MR) strain from among the 5 field-collected populations. We analyzed esterase over-expression and mutation(s) in the target sites, by using native isoelectric focusing (IEF) and quantitative sequencing (QS). We detected esterase over-expression and StoF mutation in the acetylcholinesterase 1 gene (ace1) in all of the field-collected populations, including the MR strain. We did not detect the LtoF mutation, which is a well-known knockdown resistance (kdr) mutation in the para-type sodium channel gene (para), in the MR strain; however, the value of the MR strain for bifenthrin was 3,461-fold higher than that of the susceptible strain. Our results indicate that insecticide resistance is more effectively evaluated using molecular markers than by conducting a bioassay. The molecular markers StoF in ace1 and MtoL in para can easily be applied in diagnostic methods such as QS or PCR amplification of specific alleles (PASA). These methods may be extended to management of M. persicae resistance in the field.

Effects of Body Weight Control Methods during Rearing Phase on Laying Performance in Broiler Breeder Pullets (육용종계 육성기 체중조절 방법이 산란기 생산성에 미치는 영향)

  • Na, Jae-Cheon;Lee, Sang-Jin;Jang, Byeong-Gwi;Kim, Sang-Ho;Kim, Hak-Kyu;Suh, Ok-Seok;Lee, Gin-Keon;Yu, Dong-Jo;Ha, Jeong-Gi
    • Korean Journal of Poultry Science
    • /
    • v.30 no.4
    • /
    • pp.229-233
    • /
    • 2003
  • A study was conducted to investigate the effects of different BW control methods during rearing on laying performance of broiler breeder pullets. D-old 540 female breeder chicks (Arbor Acres) were assigned to three treatments consisted of standard BW (Control), 110% of standard BW at 12 wk of age (T1), and 90% of standard BW at 12 wk of age (T2), with three replicates of 60 birds per replicate (pen) for each treatment. At 20 wk of age, all birds from three treatments reached the BW reqired in the Arbor Acres Manual. There were no significant differences in egg production, egg weight and viability during laying period(p>0.05). However, total egg production rates were improved in T2 and T3. Average egg weight was the highest in T1 among all treatments. Fertility and hatchability were similar among treatments, but T2 tended to be higher than other treatments at 37 and 53 wk of age. No significant difference was found in hatchability among three treatments. The number of hatching egg of T2 reached 168 per year, showing higher number of eggs than did the other treatments. The number of hatched chicks in T2 was 131, which was also higher than the other treatments, but the difference was not significant. It appears that the laying performance of broiler breeder hens could be improved when their BW at 12 wk of age are kept at 90% of standard BW, and reach the standard BW at 20 week of age.

International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES) (친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구)

  • Shim, Byoung Ohan
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.67-76
    • /
    • 2018
  • This study reviews three eco-friendly energy towns with hybrid thermal energy supply systems and borehole thermal energy storage (BTES) in Canada and Denmark. The district heating and cooling systems were designed by using multi-source energy for the higher efficiency and reliability as well as environment. ADEU (Alexandra District Energy Utility) located at the developing area in the city of Richmond, Canada was designed to supply district energy with the installation of 726 borehole heat exchangers (BHEs) and a backup boiler using natural gas. DLSC (Drake Landing Solar Community) located in the town of Okotoks, Canada is a district system to store solar thermal energy underground during the summer season by seasonal BTES with 144 BHEs. Brædstrup Solpark district heating system located in Denmark has been conducted energy supply from multiple energy sources of solar thermal, heat pump, boiler plants and seasonal BTES with 48 BHEs. These systems are designed based on social and economic benefits as well as nature-friendly living space according to the city based energy perspective. Each system has the energy center which distribute the stored thermal energy to each house for heating during the winter season. The BHE depth and ground thermal storage volume are designed by the heating and cooling load as well as the condition of ground water flow and thermophysical properties of the ground. These systems have been proved the reliance and economic benefits by providing consistent energy supply with competitive energy price for many years. In addition, the several expansions of the service area in ADEU and Brædstrup Solpark have been processed based on energy supply master plan. In order to implement this kind of project in our country, the regulation and policy support of government or related federal organization are required. As well as the government have to make a energy management agency associated with long-term supply energy plan.

Estimation of Total Allowable Pollutant Loads Using Eco-hydrodynamic Modeling for Water Quality Management on the Southern Coast of Korea (생태계 모델에 의한 총허용 오염부하량 산정을 통한 연안해역의 수질관리)

  • Lee, Dae-In;Kim, Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.29-43
    • /
    • 2007
  • For effective management of water quality on the southern coast of korea, a three-dimensional eco-hydrodynamic model is used to predict water quality in summer and to estimate the reduction rate in pollutant loads that would be required to restore water quality. Under the current environmental conditions, in particular, pollutant loadings to the study area were very high, chemical oxygen demand (COD) exceeded seawater quality criteria to comply with current legislation, and water quality was in a eutrophic condition. Therefore, we estimated reduction rates of current pollutant loads by modeling. The model reproduced reasonably the flow field and water quality of the study area. If the terrestrial COD, inorganic nitrogen and phosphorus loads were reduced by 90%, the water quality criteria of Region A were still not satisfied. However, when the nutrient loads from polluted sediment and land were each reduced by 70% simultaneously, COD and $Chl-{\alpha}$ were restored. When we reduced the input COD and nutrient loads from the Nakdong River by 80%, $Chl-{\alpha}$ and COD of Region B decreased below $10\;{\mu}g\;1^{-1}$ and $2\;mg\;1^{-1}$, respectively. The water quality criteria of Region C were satisfied when we reduced the terrestrial COD and nutrient loads by 70%. Total allowable loadings of COD and inorganic nutrients in each region were determined by multiplying the reduction rates by current pollutant loads. Estimated high reduction rates, although difficult to achieve at the present time under the prevailing environmental conditions, suggest that water pollution is very severe in this study area, and pollutant loads must be reduced within total allowable loads by continuous and long-term management. To achieve the reduction in pollutant loads, sustainable countermeasures are necessary, including the expansion of sewage and wastewater facilities, polluted sediment control and limited land use.

  • PDF

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.