• Title/Summary/Keyword: 유동양식 선도

Search Result 9, Processing Time 0.028 seconds

An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube (세관내 R-134a의 유동특성에 관한 실험적 연구)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1307-1312
    • /
    • 2007
  • The flow characteristics of R-134a in a small diameter tube was investigated experimentally. An experimental apparatus was consisted of a magnetic gear pump, an evaporator, a sight-glass, a condenser and a measurement instruments. The sight-glass for flow pattern observations was located at the inlet and outlet of the evaporator. The experiment was carried out to show the flow characteristics of R-134a in a small diameter tube. Mass flux of refrigerants was ranged from 100 to 1000 $kg/m^2s$, the saturation temperature was $30^{\circ}C$. In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to that in a 8 mm inner diameter tube. The evaporation flow pattern in a small diameter tube has been shown major deviations with the Baker, Mandhane and Taitel-Dutler's flow pattern maps but it was similar to the Dobson's flow pattern map.

  • PDF

Identification of Two-Phase Flow Patterns Based on Statistical Characteristics of Differential Pressure Fluctuations (차압교란치의 통계적 특성에 의한 2상유동양식의 판별)

  • 이상천;이정표;김중엽
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1290-1299
    • /
    • 1990
  • Characteristics of flow patterns in horizontal gas-liquid two-phase flow for two different sizes of pipe were investigated based upon a statistical analysis of differential pressure fluctuations at an orifice. The probability density function and the power spectral density function of the traces indicate peculiar shapes depending upon the two-phase flow regime. Mixed and separated flows also could be identified by the autocorrelation function. The transition region from separated flow to mixed flow also could be identified by these statistical properties. The experimental data determined by this method were compared with the flow pattern maps suggested by other investigators. The result indicates that the statistical characteristics of differential pressure fluctuations at orifices may be a useful tool for identifying flow patterns of horizontal gas-liquid two-phase flow.

Determination of horizontal two-phase flow patterns based on statistical analysis of instantaneous pressure drop at an orifice (오리피스 순간압력강하의 통계해석을 통한 수평 2상유동양식의 결정)

  • 이상천;이정표;김중엽
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.810-818
    • /
    • 1987
  • A new method is proposed to identify two-phase flow regimes in horizontal gas-liquid flow, based upon a statistical analysis of instantaneous pressure drop curves at an orifice. The probability density functions of the curves indicate distinct patterns depending upon the two-phase flow regime. The transition region also could be identified by the distribution shape of the probability density function. The statistical properties of the pressure drop are analyzed for various flow regimes and transitions. Finally, the data of flow patterns determined by the proposed method are compared with the flow pattern maps suggested by other investigators.

The Evaporation Flow Patterns and Heat Transfers of R-22 and R-134a in Small Diameter Tubes (세관내 R-22 and R-134a의 증발 유동양식과 열전달)

  • Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.275-283
    • /
    • 2007
  • 본 논문은 세관(ID<7 mm) 내 R-22와 R-134a의 증발 열전달과 유동양식에 대한 실험적 연구이다. R-22와 R-134a의 유동양식을 관찰하기 위해 내경 2와 8 mm의 파이렉스 튜브를 사용하였고, 열전달 계수는 내경 1.77, 3.35, 5.35 mm의 수평 평활동관에 대해서 측정하였다. 증발 유동양식에서 내경 2 mm의 환상류 영역이 내경 8 mm에 비해 저건도 영역에서 발생하는 것을 확인할 수 있었고, 내경 2 mm의 유동양식은 Mandhane의 선도와 많은 오차를 보였다. 세관(ID<7 mm) 내 증발 열전달 계수는 종래의 대구경관(ID>7 mm)에 비해 관직경에 대한 영향이 많이 나타나는 것을 알 수 있었다. 내경 1.77 mm의 열전달 계수는 내경 3.36 mm와 5.35 mm에 비해서 20내지 30% 정도 높은 것을 나타났다. 또한 종래의 열전달 상관식(Shah's, Jung's, Kandlikar's and Oh-Katsuda's correlation)과 비교한 결과, 실험 데이터는 상관식과 많은 이탈 정도를 보였다. 따라서 실험데이타를 기초로 세관내 R-22와 R-134a에 적용할 수 있는 증발 열전달 상관식을 새로이 제안하였다.

Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map (유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석)

  • Han, Hyung-Suk;Mo, Jin-Yong;Jeong, Weui-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

Vertical Upward Air-Water Two-Phase Flow Regime Identification (수직상향류 공기-물 이상유동영역 판별)

  • Lee, Ba-Ro;Jang, Young-Jun;Ko, Min-Seok;Lee, Bo-An;Lee, Yeon-Gun;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • Two-phase flow is frequently observed in many industries such as nuclear power plants and oil transportation. Two-phase flow regime depends on the flow rates, the fluid properties and the structure of flow channels. Since the identification of the flow regime is of great importance in the system design and the safety analysis, a number of theoretical and experimental investigations have been performed. This paper presents a basic research on the characteristics of each flow regime and transition boundary in the two-phase flows. The flow regime of the upward air-water flow in the vertical tube, 30 mm in the inner diameter, is distinguished by using the high-speed camera and the Wire-mesh sensor(WMS). The identified experimental data are compared with the flow regime maps proposed by Taitel et al, Mishima and Ishii. Even though there is slight difference in the transition boundary, the experimental data show general agreement with these flow regime maps.

A Study on Two-Phase Flow Pattern of Pure Refrigerants R134a and Rl23 and Zeotropic Mixture R134a/R123 in Horizontal Tubular (R134a 및 Rl23과 비공비 혼합냉매 R134a/R123의 수평관내 이상유동양식에 관한 연구)

  • Lim, Tae-Woo;Kim, Jun-Hyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1033-1041
    • /
    • 2003
  • Two-phase flow pattern data during horizontal in-tube flow boiling are presented for pure and mixed refrigerants of R134a and Rl23, The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section, which is made of a stainless steel tube, 2m long with 10mm I.D., 1.5mm wall thickness. The obtained results are compared with the available various correlations for flow pattern. The flow pattern map of Hashizume was in good agreement with the present data except the region of low mass velocity. Weisman flow pattern map was also known to satisfactorily predict data for refrigerants in the region of annular flow. In this study, the flow pattern are simply classified into two groups; stratified(including intermittent, stratified and stratified-wavy) flow and annular flow. The transition quality from stratified to annular flow was obtained by modifying the liquid Froude number.

Recurrent Plasmacytoid Myoepithelioma of the Lung - A case Report - (재발성 형질세포양 세포성 폐 근상피종 -1례 보고-)

  • 박충규;심영목
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.638-641
    • /
    • 1998
  • A recurrent myoepithelioma of the lung in a 36-year-old man is reported. The neoplasm showed histologic features identical to those described in myoepitheliomas of major and minor salivary glands on the basis of Dardick's morphological classification of Myoepitheliomas. He was treated totally with surgical en-bloc resection including the chest wall. The tumor was found to be well encapsulated, and it appeared to be mainly composed of plasmacytoid cells and clear cells with occasional microcystic spaces in a solid growth form by light microscopy. Immunocytochemical, ultrastructural and flow-cytometrical studies supported myoepithelioma differentiation.

  • PDF

A Study on the Habitait Suitability Considering Survival, Growth, Environment for Ruditapes philippinarum in Geunso Bay (Pado and Beopsan) (근소만 갯벌어장 내 바지락의 생존, 성장, 환경을 고려한 서식 적합성 연구)

  • Choi, Yong-Hyeon;Choi, Yoon-Seok;Cho, Yoon-Sik;Kim, Young-Tae;Jeon, Seung-Ryul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.6
    • /
    • pp.723-730
    • /
    • 2016
  • Domestic Manila clam production has been reduced due to coastline changes and environmental degradation, but aquaculture industry is facing difficulties caused by an increase in imports. It is important to recognize the integral habitat environment in order to do sustainable aquaculture. The habitat environment of Manila clams (Ruditapes philippinarum) is closely related to the productivity of aquaculture farms. This study investigated 3 indexes, survival (sediment type, hydrodynamic), growth (Chlorophyll a, DIN, DIP) and environment (water temperature, dissolved oxygen, sediment chemical oxygen demand, ignition loss) as indicators of habitat characteristics for a tidal flat farm in Geunso Bay (Pado and Beopsan) from June 2015 to May 2016. As a result, Pado (maximums.; sand 48.76 %, hydrodynamic 10.59 cm/s, Chlorophyll a 12.70 ug/L, exposure time 3 hours, DO 18.65 mg/L) had a higher sand content, faster current speed, more abundant nutrients and DO, providing more favorable conditions for Manila clams than Beopsan (maximums.; sand 37.40 %, hydrodynamic 6.02 cm/s, Chlorophyll a 6.41 ug/L, exposure time 7 hour, DO 14.81 mg/L). In fact, Pado showed a higher density than Beopsan. This study considered the habitat environments of Pado and Beopsan to provide a basis for optimal management practices and potential suitable sites in Geunso bay.