• Title/Summary/Keyword: 유독가스

Search Result 177, Processing Time 0.03 seconds

Characteristics of metal-loaded TiO2/SnO2 thick film gas sensor for detecting acetonitrile (아세토나이트릴 가스 검지를 위한 센스의 제작 및 특성)

  • Park, Young-Ho;Lee, Chang-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 2009
  • This study investigated sensitivity of the gas sensor to chemical weapons with the sensor material doped with catalysts. The nano-sized SnO2 powder mixed with metal oxides (TiO2) was doped with transition metals(Pt, Pd and In). Thick film of nano-sized SnO2 powder with TiO2 was prepared by screen-printing method onto Al2O3 substrates with platinum electrode and chemical precipitation method. The physical and chemical properties of sensor material were investigated by SEM/EDS, XRD and BET analyzers. The measured sensitivity to simulant toxic gas is defined as the percentage of resistance of value equation, [(Ra-Rg)/$Ra\;{\times}100$)], that of the resistance(Ra) of SnO2 film in air and the resistance(Rg) of SnO2 film in acetonitrile gas. The best sensitivity and selectivity of these thick film were shown with 1wt.% Pd and 1wt.% TiO2 for acetonitile gas at the operating temperature of $250^{\circ}C$.

  • PDF

A Study on the Law History of Tunnel Disaster Prevention in Korea (국내 터널관련 방재법령의 변천에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kim, Jung-Hee;Kwon, Young-Jin;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.235-240
    • /
    • 2009
  • 지하에 건설되는 터널은 구조상 반 밀폐적인 특성을 가지고 외부와 차단되어 있기 때문에 화재발생시 연기에 의한 질식의 위험성이 크고 다수의 이용자들이 쉽게 패닉현상에 빠지게 되고 많은 연기와 유독가스에 노출되어 생명의 위협을 받게 된다. 또한 연기와 유독가스 호흡에 의한 체내유입은 인체상의 여러 가지 부작용을 초래하는 등 피해를 가져올 수 있다. 이러한 피해를 예방하고 최소화하기 위해 방재설비를 시설하고 운영하는데 국내의 방재시설에 대한 규정은 지하공간을 관리 관장하는 기관과 용도에 따라 각각 다르게 적용하고 있어 터널관련 방재시설의 변천에 대하여 알아보고 현재의 설치 기준과 문제점을 살펴보았다.

  • PDF

A Study on the Law History of Tunnel Disaster Prevention in Korea (국내 터널관련 방재법령의 변천에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kim, Jung-Hee;Kwon, Young-Jin;Han, Byung-Chan;Kim, Jae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.45-50
    • /
    • 2009
  • 지하에 건설되는 터널은 구조상 반 밀폐적인 특성을 가지고 외부와 차단되어 있기 때문에 화재발생시 연기에 의한 질식의 위험성이 크고 다수의 이용자들이 쉽게 패닉현상에 빠지게 되고 많은 연기와 유독가스에 노출되어 생명의 위협을 받게 된다. 또한 연기와 유독가스 호흡에 의한 체내유입은 인체상의 여러 가지 부작용을 초래하는 등 피해를 가져올 수 있다. 이러한 피해를 예방하고 최소화하기 위해 방재설비를 시설하고 운영하는데 국내의 방재시설에 대한 규정은 지하공간을 관리 관장하는 기관과 용도에 따라 각각 다르게 적용하고 있어 터널관련 방재시설의 변천에 대하여 알아보고 현재의 설치 기준과 문제점을 살펴보았다.

  • PDF

사고 사례 - 방직공장 화재사례

  • Kim, In-Tae
    • 방재와보험
    • /
    • s.111
    • /
    • pp.58-61
    • /
    • 2006
  • 방직 공장은 섬유의 착화 용이성, 원료의 밀집도, 연속공정으로 발화순간 전체 공정으로 연소가 확대되기 쉬우며, 착화되면 다량의 연기와 유독가스를 발생하기 때문에 항상 화재에 대한 각별한 주의가 요구되는 곳이다. 공장 화재 사례를 통해 문제점 및 각종 대책에 대해 알아보자.

  • PDF

A Toxicity of Interior Upholstery in Apartment Housing (아파트 마감재의 연기 유독성)

  • Ham, Sang-Keun;Kim, Hong;Han, Sang-Bum;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.36-43
    • /
    • 2001
  • Several types of widely used interior upholsteries including wallpaper, veneer board and floor cover, were selected to be evaluated by using the method of NES 713 text. Test results indicates that a fire with retardant wallpaper release a large amount of toxic gases when constantly exposed to a fire source. When evaluated in terms of the masses of released gases, the release of Carbon monoxide appears the highest in case of wallpaper fire, while the ratio of CO/Mass loss appears the highest in case of floor cover fire. Therefore, it can be concluded that, a large amount of toxic gas will release from a floor cover fire with even a small quantity of fuel.

  • PDF

Deep learning based optimal evacuation route guidance system in case of structure fire disaster (딥러닝 기반의 구조물 화재 재난 시 최적 대피로 안내 시스템)

  • Lim, Jae Don;Kim, Jung Jip;Hong, Dueui;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1371-1376
    • /
    • 2019
  • In case of fire in a structure, it is difficult to suppress fire because it can not accurately grasp the location of fire in case of fire. In this paper, we propose a system algorithm that can guide the optimal evacuation route in case of deep learning-based (RNN) structure disaster. The present invention provides a service to transmit data detected by sensors to a server in real time by using installed sensor, to transmit and analyze information such as temperature, heat, smoke, toxic gas around the sensor, to identify the safest moving path within a set threshold, to transmit information to LED guide lights and direction indicators in a structure in real time to avoid risk factors. This is because the information of temperature, heat, smoke, and toxic gas in each area of the structure can be grasped, and it is considered that the optimal evacuation route can be guided in case of structure disaster.

Study on the Preparation of Thin film gas sensors (박막 가스 검지후소자의 제조에 관한 연구)

  • 이덕동;김봉열
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.1
    • /
    • pp.35-40
    • /
    • 1981
  • Thin films of SnO2, SnO2-ZnO and ZnO were prepared by the spray. chemical vapor deposition and vacuum evaporation method. They had good sensitivity to various gases involving toxic gases(i. e. SO2, CO). The change in conductivity of thin film guts sensors prepared was considered as the change in carrier concentration caused by gas absorption. And also the conductivity of the thin film elements had great dependence on atmospheric pressuie around them.

  • PDF

A Study for pathological observations on the exposured mouse to the HCl (HCl에 노출된 mouse의 병리학적 관찰에 관한 연구)

  • Cho, Nam-Wook;Chun, Ji-Hong;Lee, Jong-Cheon;Lee, In-Koo;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.361-364
    • /
    • 2012
  • 최근의 건축물은 다양한 소재의 마감재를 사용함으로서 화재 발생시 다양한 연소가스를 배출한다. 이때 건축물 내부의 화재에 노출된 재실자는 열 및 화상의 위험성과 함께 연기 및 독성가스의 피해를 받기 쉽다. 본 연구에서는 건축물 화재시 발생될 수 있는 HCl에 대한 표준가스를 제작하여 가스유해성시험을 수행하고, HCl 표준가스에 노출된 실험용 쥐의 표적장기적출실험을 수행하였다. 이를 통해서 유독가스에 노출된 실험용 쥐의 해부를 통한 표적장기-심장(Heart), 간(Liver), 폐(Lung), 비장(Spleen), 신장(Kidney), 흉선(Thymus)-의 손상여부와 KS F 2271에 의한 평균행동정지시간과의 관계를 분석하였다.

  • PDF

발포 프라스틱 단열재의 착화특성 및 연소가스 분석

  • 이근원;김관응;양성환
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.124-129
    • /
    • 2000
  • 산업현장의 건물, 설비 등의 보온 및 단열을 위해 우레탄폼, 스치로폼 등 다양한 종류의 프라스틱류 단열재를 사용하고 있다. 이들은 착화 및 연소속도가 빠르고 연소시 유독가스를 다량 발생시켜 심각한 재산 및 인명피해를 초래하고 있다. 그러나, 이들 발포플라스틱들은 연소하기 쉬운 재료로서 급속한 화염전파, 높은 열방출율, 많은 양의 연기발생 등 화재의 위험성이 상대적으로 높다는 문제점을 안고 있다. (중략)

  • PDF

A Study on Carbon Monoxide and Other Gases During the Fire Test (A-class:1st Rating & B-class:1st Rating) (한국 A급, B급 1단위 화재 시험시 발생하는 일산화탄소 등의 정량적 연구)

  • Jeong, Incheon;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.44-56
    • /
    • 2013
  • This research is to identify how much toxic combustion gases are produced from Korea standardized real fire test (Class A&B) by using Room Corner Tester (RCT) and how much those gases are possibly dangerous to testing personnel by estimating the level of carboxyhemoglobin (% COHb). It is confirmed that testing personnel can be affected as more than 40% COHb from Class A 9th and 10th rating in respiration minute volume (RMV) 2 and from Class A 5th to Class A 10th rating in RMV 3 during the time for initial three minutes. Also, in the case of Class B real fire tests, although it is considered rather safe for the initial 1 minute, testing personnel can be affected as more than 20% COHb from Class B 16th to 20th rating in RMV 3 during total test time. Currently, the Korea standard is only focusing on the protection measures against the heat, but the it is neglecting the protection measures against toxic combustion gases. Therefore, according to this study, it is strongly recommended that testing personnel should wear a self-contained breathing apparatus, or the equivalence depending on the real fire test rating.