Current status of brominated flame retardants (BFR) and polybrominated dibenzo-p-dioxins and furans (PBDDs/PBDFs) (브롬화난연제 및 브롬화다이옥신류의 연구동향)

  • Kwon, Myung-Hee;Song, Ki-Bong;Kang, Yung-Ryul;Hwang, Seung-Ryu;Shin, Sun Kyoung;Kim, Kum-Hee;Park, Jin Soo;Kim, Sue-Jin;Lee, Su-Yung;Kim, Dong-Hoon;Jung, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.443-458
    • /
    • 2008
  • Brominated flame retardants (BFRs) are chemical compounds that inhibit the combustion of organic materials by scavenging free radicals that would otherwise encourage the spread of flames. These compounds are found in a wide variety of materials including paints, plastics, textiles, furniture and electronics. Mounting evidence, however, suggests that the non-reactive BFRs can easily leach into the environment and pose significant environmental and health concerns. PBDDs/PBDFs are often formed in the process of manufacturing brominated flame retardants and from the combustion of waste products containing flame retardants BFR. Therefore, this paper describes the general characteristics, management status, residual concentration in environments and analytical method.

전처리공정이 천연유기물질의 움집에 미치는 영향

  • 이주영;이석모
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.67-67
    • /
    • 1997
  • 정수공정은 "원수 -1 침사지 1 전염소 -1 전오존 -1 침전지 1 여과지 1 후오존 1 GAC 4 후염소 1 가정수"로 이루어져 있으며 전처리 공정으로 염 소와 오존을 주입하게 되는데, 여기서 전염소 처리 공정으로 인해 잔류 유리염 소가 수중의 유기물질과 반웅하여 유해성 유기염소 화합물 (i.e.. Trihalomethane, Haloacetonitriles, Chlorophenol 등)을 생성하는 것으로 알려져 있다. 이러한 이유로 고도 정수처리 공정에서는 강한 산화력을 지닌 대체 산화 제로서 오존을 이용하고 있다. 전오존 처리공정은 OOC와 탁도 제거에 있어 응 집제 주입량을 감소시키는 것과 더불어 전오존 효과 (산화, 생분해 증대, 살균 등)를 얻을 수 있는 것으로 알려져 왔다. 그러나 낙동강과 같이 유기물이 많은 원수에 과다한 오존이 주입되면 수중 의 유기물이 저분자화 또는 응집이 어려운 오존 산화물로 변화하여 응집제의 소비가 많아지게 된다. 실제, 오존을 응집 효과에 대해서 pilot plant로 운전한 결과 전오존에 의해 입자성 물질의 제거 효율은 향상된 반면에 유기물 제거는 뚜렷한 효과를 볼 수 없었다고 보고되었다 (류, 1997). 본 연구에서는 물금 지역의 원수와 응집-침전 공정까지 거치는 각각의 처 리수에 대해서 전처리가 응집에 미치는 영향을 천연유기물질 (NOM)의 조성 변화로 파악하였다. 그 방법으로 천연유기물질 (NOM)을 XAD-1, -4 수지를 이 용하여 소수성 물질 (hydrophobic components)과 친수성 물질 (hydrophilic components)로 분리 및 농축하여 용존 유기물이 처리 과정에서 어떻게 변화하 는지를 조사하여 개선된 상수 처리 시스템을 설계하는데 기초 자료를 제공하고 수질 관리 분야에서도 적용하고자 하였다. 상수원수인 물금 지역의 소수성 물질(hydrophobic components)은 75~80%, 친수성 물질(hydrophilic components)은 30~33%정도의 분포를 보였고, 전염소 및 전오존 공정을 거친 처리수에서는 각각 62.2-62.8%, 43.9~49.0% 및 50~ 55%, 40~57% 정도의 분포를 보였다. 그리고 웅집-침전을 거친 처리수에서는 그 분포가 77~82%, 24-48%였다. 전주리 공정을 통하여 소수성 물질(byoghobic components)의 분포가 감 소하는 것을 볼 때 전염소 및 전오존 처리가 용존유기물의 응집에는 오히려 역 효과를 나타내는 것으로 판단된다. 것으로 판단된다.

  • PDF

Selection of the Optimum Organic Matter Index for Surface Water Quality Management (지표수 수질관리를 위한 적정 유기물질지표 선정)

  • Han, Dae Ho;Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.10 no.4
    • /
    • pp.61-80
    • /
    • 2011
  • Through concentrated investments in environmental regulations centered around BOD, which is a biodegradable matter index, and basic environmental infrastructures, national BOD pollution level has continuously improved. Nonetheless, limitations of BOD management system has become evident through nation-wide stagnation and/or increases of refractory organic matters, such as COD, at main drinking water sources, and the need for a new index, which can easily indicate different environmental conditions, has increased. Therefore, this study suggests a new organic management index for a proper management of surface water. $COD_{Cr}$ and TOC were examined as candidates for surface water quality management index, and it was found that TOC was more appropriate than $COD_{Cr}$ as an organic matter management index. Through this study, it was found that TOC possesses following qualities: a more representative index; international acceptability; monitoring program is easier; better availability of analysis techniques; better accuracy and precision of analysis; less time required for analysis; ease of operation; management of disinfection byproducts; connection with present policies; existence of foreign and domestic application case studies; and correlation with water ecosystem.

  • PDF

Removal of Heavy Metal and Organic Substance in Contaminated Soils by Electrokinetic and Ultrasonic Remediation (동전기 및 초음파 복원기술에 의한 오염지반내의 중금속 및 유기오염물질 제거)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2003
  • The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique to remove mainly organic substance in contaminated soil. In this study, the combined electrokinetic and ultrasonic remediation technique was studied far the removal of heavy metal and organic substance in contaminated soils. This study emphasized the coupled effects of electrokinetic and ultrasonic techniques on migration as well as remediation of contaminants in soils. The laboratory soil flushing tests combining electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of both of these techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

Volatile Organic Compound Levels inside Vehicles using Commercial Air Cleaning Devices (상업용 공기정화기 사용 차량 내 휘발성 유기물질 수준)

  • Wan-Kuen Jo;Kun-Ho Park
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.659-670
    • /
    • 1997
  • Vehicle occupant exposure to volatile organic compounds (VOCs) has been a subject of concern In recent years because of higher levels of VOCs Inside vehicles as compared to the surrounding ambient atmosphere and because of the toxicity of VOCs. The effectiveness of two commercial ACDs for the removal of selected VOCs in the interior of automobiles was evaluated on 115 commutes throegh urban (Taegu) commutes by two cars and 9 idles. The idling and commuting studios conducted under four different driving conditions showed that the ho commercial ACDs were not effective for the removal of VOCs in the interior of vehicles. The concentrations of all target VOCs except benzene were significantly higher (p<0.05) in the interior of older car than of newer cu. The mean levels of benzene and toluene measured in thins study were well excess of earlier other studios In the United States, besides Los Angeles with which was comparable. It was reported that the in-vehicle exposure to benzene and corresponding upper-bound cancel risk were about 8 times higher than those for outdoor environment, while they were about half of those from Indoor environment.

  • PDF

Characteristics and Effective Usage of Organic Indexes in Water Environments -Lakes in Nakdong River Basin- (물환경에서의 유기물질 지표 특성 및 효율적 이용방안 -낙동강수계 호소수를 대상으로-)

  • Kang, Meea
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.153-160
    • /
    • 2014
  • TOC environmental standard was established to understand the pollution level accurately and to improve the water quality. It was found that the relationship between COD and TOC showed a significant coefficient($R^2$=0.639) in four lakes for drinking water located in Nakdong River basin. The relationship between COD and TOC($R^2$=0.774) was higher with respect to the elevated concentration level when the data was added. Resulting in the oxidation(C) was $62{\pm}8%$ regardless of COD concentrations. It was difficult to find a significant difference by lakes. The result showed the similar organic property in study lakes. It was necessary to evaluate the level of organic matters in consideration of characteristics and utilization of lakes to use COD data wisely until TOC data be accumulated sufficiently.

Recycling Water Treatment of Aquaculture by Using Three Phase Fluidized Bed Reactor (삼상유동층 반응기를 이용한 양어장 순환수 처리에 관한 연구)

  • LEE Byung-hun;KIM Jeong-sook;KANG Im-suk
    • Journal of Aquaculture
    • /
    • v.7 no.3
    • /
    • pp.177-187
    • /
    • 1994
  • The objective of the present study were to evaluate nitrification characteristics and determine optimum treatment conditions of three phase fluidized bed reactor for recycling water treatment of aquaculture. When the loading rates were 2.739-0.086kg $COD/m^3/day$ and 1.575-0.128kg $NH_4\;^+-N/m^3/day$, COD and ammonia removal efficiencies were $56.3-94.7\%\;and\; 67.3­92.6\%$, respectively. The maximum removal rates of COD and ammonia were 1200mg/l/day and 488mg/l/day, respectively. Ammonia removal rates were more than $90\%$ beyond 1hr HRT. The ammoniaremoval efficiency was sensitive to the variation of media concentration and air flowrate.

  • PDF

형광 발광층과 인광 발광층으로 구성된 하이브리드 발광층을 가진 청색 유기발광소자의 색 순도와 색안정성 증진

  • Bang, Hyeon-Seong;Chu, Dong-Cheol;Kim, Tae-Hwan;Seo, Ji-Hyeon;Kim, Yeong-Gwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.272-273
    • /
    • 2011
  • 유기발광소자는 차세대 디스플레이 소자로서 빠른 응답 속도, 높은 색 재현성 및 매우 얇은 두께로 제작이 가능한 장점을 가지고 있어서 차세대 디스플레이 소자로서 많은 응용 가능성을 가지고 있다. 청색 유기발광소자는 적색 및 녹색의 유기발광소자의 발광 효율 특성보다 상대적으로 효율이 떨어지고, 색 순도가 낮으며 수명이 짧은 단점을 가지고 있어 소자 특성을 개선해야 한다. 본 논문에서는 청색 유기발광소자의 색 순도와 색 안정성 증진을 위하여 발광층을 2개의 층으로 나누어 15 nm 두께의 4,4'-Bis(2,2-diphenyl-ethen-1-yl)diphenyl (DPVBi) 형광 청색 호스트 물질에 4,4 '-Bis[4-(diphenylamino)stylyl]biphenyl (BDAVBi) 형광 청색 게스트 물질을 첨가하여 제 1 형광 발광층을 형성하고 15 nm 두께의 4,4'-Bis(carbazol-9-yl)biphenyl (CBP) 인광 호스트 물질에 bis(3,5-difluoro-2-(2-pyridyl)phenyl-(2-carboxypyridyl)iridium III (FIrpic) 인광 게스트 물질을 첨가한 제 2 인광 발광층으로 구성된 30 nm 두께의 하이브리드 발광층을 사용하여 청색 유기 발광소자를 제작하고 전기적 특성과 광학적 성질을 조사하였다. 하이브리드 발광층을 사용하여 제작된 유기발광소자는 20 mA/cm2의 전류 밀도에서 6.2 cd/A의 발광 효율을 나타내었고, 최대 밝기는 약 16,200 cd/m2로 측정 되었다. 하이브리드 발광층을 사용한 청색 유기발광소자는 전류의 흐름이 단일 발광층 유기발광소자에 비교하여 상대적으로 안정적인 전류 흐름을 가지며 발광층 내부에 더 많은 정공과 전자를 포획하여 엑시톤 형성 확률이 증가하여 발광효율과 밝기가 향상되었다. 하이브리드 발광층을 적용한 유기발광소자는 469 nm파장에서 형광 발광층의 주 전계발광 피크가 나타났고 그와 함께 인광 발광층의 부 전계발광 피크가 491 nm의 파장에서 관측되었다. 또한 전계발광 스펙트럼의 반치폭이 10 nm 감소하여 청색의 색 순도 증가에도 기여하였다. 하이브리드 발광층을 가진 청색 유기발광소자의 색 좌표는 전압 변화에 관계없이 일정한 값을 나타내었다. 이러한 결과는 형광과 인광 발광층으로 구성된 하이브리드 발광층 유기발광소자가 전기적으로 안정성을 가지며 발광 특성을 개선하고 안정적인 청색 유기 발광 디스플레이 소자로 사용 가능함을 나타내고 있다.

  • PDF

Analysis of digital monitoring of TOC using a spectrometer in river (하천에서의 분광측정기를 이용한 TOC 디지털 모니터링 분석 연구)

  • Soo Bin Yoon;Chang Hyun Lee;Ho Soo Lee;Ye Lim Park;Young Do Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.195-195
    • /
    • 2023
  • 유기물오염은 호수와 하천에서 가장 흔히 나타나는 오염의 형태이다. 개발도상국에서는 하수처리시설이나 생활용수처리시설에서 유기물이 처리되지 않아 수중의 유기물함량이 증가하여 피해가 나타난다. 물환경보전법에 따라 유기물질을 측정하는 지표에는 BOD, COD, TOC가 있다. 그 중 BOD, COD 측정은 절차가 복잡하고 오래 걸리며, 생물분해가 불가능하거나 유독물질이 존재하는 유기물질인 경우에는 낮은 결과 또는 측정이 불가능하다. 이러한 이유로 환경부에서는 TOC중심관리로 전환되고 있다. 대부분의 수질항목 측정의 경우 현장시료를 채취하여 실험실에서 분석하는 수분석을 이용한다. 하지만 수분석의 경우 인력이 많이 투입되고 분석수가 한정적이며, 정교한 과학 장치를 갖춘 전문 실험실을 필요로 한다. 반면에 TOC는 짧은 시간 내에 측정이 가능하고, 안정적인 산화로 유기물질 총량을 정확하게 측정이 가능하다. 또한 위해성 물질을 발생시키지 않는 친환경적 방법이라 환경오염 감시에 많이 활용된다. 본 연구에서 분광측정기 중 하나인 S-CAN을 통해 하천의 TOC분석을 진행하였다. 대상지는 안동에 위치한 하천실험센터와 금호강 진천천으로 S-CAN측정과 채취한 시료의 수분석 결과를 비교하였다. 이를 통해 TOC측정 및 기기에 대한 정확도분석을 실시하였다. 본 연구를 통해 S-CAN을 활용한 TOC중심의 수질모니터링하여 수질의 특성을 탐구하고, TOC기초연구를 통한 유기물오염도 지표로서 해석할 수 있다. 수분석 자료를 활용한 정확도 비교를 통해 하천 TOC센서 측정 적용에 대한 기초자료 제공과 측정기기의 현장적용성을 판단 할 수 있다. TOC측정 및 분석을 통해 유기물질량을 실시간으로 정확하게 측정하게 되면 수질관리 효율성이 높아지고, 하천에 유입되는 유기물질량과 농도를 정확하게 파악하여 실효성 있는 정책 수립 및 효율적인 수질관리를 할 수 있다.

  • PDF