• Title/Summary/Keyword: 위상배열초음파검사

Search Result 43, Processing Time 0.029 seconds

A Software Approach for the Realtime Received Signal Processing in Magnetostrictive Long-Range Ultrasonic Testing (자왜형 원거리 초음파검사에서 실시간 수신신호 처리를 위한 소프트웨어 접근)

  • Heo, Won Nyoung;Lim, Hyung Taik;Kim, Tae Gyung;Choi, Myoung Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.540-544
    • /
    • 2012
  • Like the phase array based ultrasonic system, complicated electronics has been used for real time signal processing in the magnetostrictive long-range ultrasonic testing(LRUT) system. This study shows that the software approach including the phase compensation, noise filtering and waveform transformation takes advantage rather than the previous hardware approach. Furthermore, it is possible for the software approach to be able more flexible and efficient realtime signal processing. These results will contribute to a cost-effective LRUT system and analysis of the inspection data.

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

A Development of diagonostic technique for generator rotor wedge by phased array UT (발전기 회전자웨지 위상배열 초음파진단 기법)

  • Cho, Yong-Sang;Mun, Kyeong-Hee;Kong, Tae-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.902-903
    • /
    • 2011
  • 발전설비에 대한 비파괴 검사 기술은 발전소 운전 신뢰성 및 안전성 유지확보 그리고 건전성을 보장하기 위한 필수적인 기술이다. 이 설비 중 터빈, 보일러 등 주요 발전설비에 대한 초음파 검사는 매우 신중하고 정확하게 검사할 필요성이 있으나, 일반적 초음파 검사방법으로는 불가능한 부분이 많고 일부분에 대해서는 이를 외국 제작사 기술용역에 의존하고 있는 실정이다. 특히 발전기 로타 웨지와 같이 재질상 감쇄가 심한 재료에 대해서는 검사 자체가 어렵고, 지금의 초음파 검사 방법으로는 결함의 크기나 형태를 파악하기도 어려워 이에 대한 개선책이 시급한 실정이다. 최근에 개발이 시작된 Phased Array UT분야는 발전설비중 접근자체가 어렵고, 형상이 복잡하여 결함의 탐지 및 평가가 힘든 부분에 적용하면 검사신뢰도 및 신속성을 향상시킬 수 있으며 접근성에 대한 제한 또한 감소시킬 수 있다. 따라서 본 논문은 발전기 부품에 발생하는 일반적인 결함에 대하여 Phased array UT 기술을 도입하여 신호의 특성을 분석하는 결과평가에 도음이 되고자 하였다.

  • PDF

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

초음파 물체 이송시스템의 이송 메커니즘에 대한 연구

  • 정상화;최석봉;차경래;김광호;박준호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.160-160
    • /
    • 2004
  • 초음파 여기를 이용한 물체 이송 시스템은 최근 급속히 발달하고 있는 광산업이나 반도체 산업에서 기존의 이송 시스템의 단점을 보완하기 위해 개발되었다. 기존의 이송 시스템들은 이송공정이나 검사 공정 등에서 광소자의 표면손상이나 자기장에 의한 반도체 소자의 전자적 배열의 손상이 우려되었다. 하지만 PZT 액츄에이터로 구동되는 초음파 발생장치(Ultrasonic wave generator)에서 발생한 초음파 여기를 이용하여 물체를 이송시킬 경우 이러한 단점은 보완된다.(중략)

  • PDF

Development of Ultrasonic Testing System for In-Service Inspection of the Shrunk-on Type LP Turbine Roter (Shrunk-on Type 저압 터빈 로터의 가동중검사를 위한 초음파검사 시스템 개발)

  • Park, Joon-Soo;Seong, Un-Hak;Ryu, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • Turbine, which is one of major components in nuclear power plants, requires reliable nondestructive inspections. But, accessibility of transducers is limited and interpretation of acquired signals is not easy at all due to the complication. So, in this study, we have fabricated mock-up specimens of real size and shape. we applied pulse-echo method and time-of-flight diffraction(TOFD) method for precise inspection of turbine key and wheel bore. And phased array ultrasonic testing method was adopted for wheel dovetail of turbines by using mock-up. Furthermore, an automatic scanner system was developed for in-service inspection of the developed methods.

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Realtime Identification of the Propagation Direction of Received Echoes in Long-Range Ultrasonic Testing (원거리 초음파검사에서 수신에코 진행방향의 실시간 식별)

  • Choi, Myoung Seon;Heo, Won Nyoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.69-72
    • /
    • 2013
  • In long-range ultrasonic testing, a phased array probe composed of multiple identical transducers with an uniform interval of one quarter wavelength is usually used for the transmission or reception directivity control. This paper shows that the propagation directions of individual echoes can be identified in real time by displaying the inputs of a process for summing the constitution reception signals after compensating the phase difference due to the transducer interval, together with the output of the process. A constructive interference of the constitution echoes indicates a forward direction echo propagating along an intended direction while a destructive interference implies a reverse direction echo propagating along the direction opposite to the intended one.

Guided Wave Phased Array for Inspection of Plate Structures (유도초음파 위상배열을 이용한 판 구조물 검사)

  • Kwon, Hyu-sang;Park, Seong-Chol;Cho, Seung-Hyun;Lee, Seung-Seok;Kim, Jin-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.699-704
    • /
    • 2008
  • This paper describes a general approach for processing data from an omni-directional guided wave transducer array for the rapid inspection of large plate structures. A basic phased array algorithm is presented that can be applied to any array Geometry. For guided waves on plate, beam steering algorithm is derived and the corresponding beam pattern is analyzed. The algorithms are applied to simulation and experimental data. The results show well its usefulness in structural applications.

  • PDF

Evaluation Technology for the Flaw Sizing of Generator Rotor by Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 발전기 로터 결점크기 평가)

  • Kim, Jin-Hoi;Park, Cher-Young;Lee, Sang-Hoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.14-19
    • /
    • 2009
  • NDE(Nondestructive examination) detects a flaw or discontinuity in materials. Flaws detected by the examination shall be evaluated for the decision basis of the integrity. The internal flaws of forging products can be detected by UT. However, UT has detection limits because of its reflected signal weakness. Normally, a 1mm or less flaw is known as the limit. If a flaw was detected, the size of flaw would be evaluated by AVG(or DGS) technique. To verify the evaluation data, alternative examination methods are needed. But there is no alternative examination methods until now. In this study, Phased array ultrasonic technique can be used to size the flaws in the generator rotor with focused beam of ultrasonic wave as a supplement method of AVG. Also, the phased array ultrasonic technique described enables the shape of flaw to be depicted exactly.

  • PDF