• Title/Summary/Keyword: 위상감지법

Search Result 7, Processing Time 0.02 seconds

Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis (세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석.)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.43-57
    • /
    • 1992
  • Phase detector techique provides a unique probe to membrane recycling phenomenon by enabling dynamic monitoring of cell membrane capacitance. However, it has inherent errors due to constant changes in measurement environments. The present study analyzed several error sources to develope application criteria of this technique. and the following was found based on a theoretical analysis. The initial phase angle has to be appropriately selected to minimize the error due to perturbation of access and membrane conductances. Excitation frequency is also important to determine the initial phase angle. However. deviation of the phase angle from a predetermined initial value during the measurement period does not affect capacitance estimation to a significant degree. Despite an appropriate initial phase selection an error in scaling factor is expected for a large increase in capacitance during exocytosis. which may be overcome by iteratively correcting the scaling factor over the measurement period. These results will provide a useful guideline in practical application of this technique.

  • PDF

A Basic Study on the Measurement of Velocity Distribution of Underwater Targets (수중 물체의 속도 분포 측정에 관한 기초 연구)

  • 이은방;이상집
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 1996
  • 초음파는 액체 및 고체의 매질 속에서도 그 전달 특성이 우수하여 수중 물체의 감지, 지질 조사 자원탐사뿐만 아니라, 의학 분야에서도 널리 사용되고 있다. 물체유동정보 측정방식에는 연속파를 이용한 도플러식과 펄스 신호를 이용한 도플러는 거리 분해능이 좋으므로 깊이에 따른 속도 정보를 쉽게 얻을 수 있는 장점이 있으나, 수신되는 도플러 신호가 탐촉자의 특성과 매질 속에서의 전파특성 등에 의하여 송신된 신호와 파형이 다르고 복잡한 주파수 특성을 가지므로 연속파에서와 같이 도플러 주파수를 직접 측정하기 곤란하다. 도플러 주파수를 검출하기 위하여 여러 방법이 개발되어 있으나, 측정거리와 측정속도의 제약과 더불어, 실시간(real time) 처리에 의한 분포적 측정이 어려운 실정이다. 본 연구에서는 시간 영역에서 국소 데이터를 이용하여 펄스 신호의 위상을 정의하고 실시간에서 펄스 신호를 위상으로 변환하는 신호 처리법을 제안하였다. 또한 이 신호 처리법을 응용하여 측정 범위의 위상 곡선에서 위상 차를 계산함으로써 평균 가속도와 유동속도정보를 분포적으로 얻을 수 있는 새로운 펄스 도플러 기법을 제안하였으며, 모델 신호를 만들어 제안된 방법의 유용성을 검토하였다.

  • PDF

Vehicle Collision Avoidance Sensor with Interference Immunity to Own Transmitted Signal (자차 송신기 신호 간섭회피 기능을 갖는 차량의 충돌방지 센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.433-438
    • /
    • 2013
  • Interference reduction method of vehicle collision avoidance sensor which is used for the low speed electric vehicle has been investigated. Various methods were attempted for the vehicle collision avoidance distance sensor, which received a transmitted signal from a front driving vehicle to measure the distance between two vehicles, to avoid interference by the own transmitter signal toward the rear following vehicle. In this study, -12dB of interference cancellation ratio was realized by using the phase cancellation method to the transmitted signal from the own vehicle. Proposed phase cancellation method is regarded to have the advantage of continuous monitoring in comparison to the conventional time sharing transmitting and receiving method.

Evaluation of phase velocity in model rock mass using wavelet transform of surface wave (표면파에 대한 웨이블렛 변환을 이용한 모형 암반의 위상속도 예측)

  • Lee, Jong-Sub;Ohm, Hyon-Sohk;Kim, Dong-Hyun;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.1
    • /
    • pp.69-79
    • /
    • 2008
  • Prediction of ground condition ahead of tunnel face might be the most important factor to prevent collapse during tunnel excavation. In this study, a non-destructive method to evaluate the phase velocity in model rock mass using wavelet transform of surface wave was proposed aiming at ground condition assessment ahead of tunnel face. Model tests using gypsum as a rocklike material composed of two layers were performed. A Piezoelectric actuator with frequencies ranging from 150 Hz to 5 kHz was selected as a harmonic source. The acceleration history was measured with two accelerometers. Wavelet transform analysis was used to obtain the dispersion curves from the measured data. The experimental results showed that the near-field effects can be neglected if the distance between two receivers is chosen to be three times the wavelength. A simple inversion method using weighted factor based on the normal distribution was proposed. The inversion results showed that the predicted phase velocity agreed reasonably well with the measured one when the wavelength influence factor was 0.2. The depth of propagation of surface wave was from 0.42 to 0.63 times the wavelength. The range of wavelength varying with phase velocity in dispersion curve matched well with that estimated by inversion technique.

  • PDF

Defect Detection of Impacted Composite Tubes by Lock-in Photo-Infrared Thermography Technique (위상잠금 열화상기법을 이용한 복합재 튜브 충격 손상 결함 측정)

  • Kim, Kyoung-Suk;Jeon, So-Young;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.139-143
    • /
    • 2011
  • The problem of delamination of composite tubes by impact has been acknowledged in aerospace and automobile industry. Non-destructive testing(NDT) methods in composite material structure are important to evaluate reliability of composite structure. There are many kinds of NDT methods which can detect the inside defect of the composite material such as Infrared Thermography(IRT). Infrared thermal imaging of object is different from that of a defect, in heated composite tubes with an internal defect, and then location and size of a defect can be measured by the analysis of thermal imaging pattern. In this study, Lock-in Infrared thermography detect internal defects of Impacted composite tubes by the inspection of infrared lay radiated from the surface of composite tubes.

Evaluation of 2D Shear Wave Velocity Imaging of Subground Using HWAW Method (HWAW 기법을 이용한 지반의 2차원 전단파 속도 평가)

  • Kim, Jong-Tae;Park, Hyung-Choon;Bang, Eun-Seok;Park, Heon-Joon;Kim, Dong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.105-114
    • /
    • 2007
  • Two-dimensional imaging of $V_s$ profile becomes more important in Korea because of the large horizontal variation of soil stiffness. To obtain a shear-wave velocity profile in geotechnical practice, various seismic nondestructive investigation methods are being frequently used. In this study, harmonic wavelet analysis of wave (HWAW) method is applied to the determination of $V_s$ profile to overcome some of weaknesses in the existing surface wave methods. HWAW method which is based on time-frequency analysis using harmonic wavelet transform has been developed to determine phase and group velocities of waves. Field testing of this method is relatively simple and fast because one experimental setup which consists of one pair of receivers is needed to determine $V_s$ profile of site. The proposed method uses the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity to minimize the effects of noise, and uses single array inversion which considers receiver locations. Field tests were performed in 2 sites in order to evaluate accuracy of test method and estimate the applicability of 2-D imaging by HWAW method. Through field applications and comparison with other test results, the good accuracy and applicability of the proposed method were verified.

A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method (광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구)

  • You, I.H.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • We have studied methods of detecting attenuation of solid materials such as silicon wafer and piezoelectric $LiTaO_3$ by means of optical probing techniques. We have performed measurements of surface acoustic waves(SAW) generated from 90 degree wedge type transducer and also from inter-digital transducers(IDT). SAW of 20.0 MHz was generated on a silicon wafer from the 90 degree wedge type transducer and those of 20.8 and 14.5 MHz are generated on a $LiTaO_3$ from the IDT. Then any surface-corrugation resulted from the above SAW was investigated by He-Ne laser beams. We projected laser beams, which were modulated by an optical chopper, on the SAW of the same frequency and then measured the scattered beam by the lock-in amplifier. We modulated and synchronized both SAW and the incident laser beam as well as the phase sensitive detector(PSD) to the same frequency in order to simplify our measurement system. We obtained the attenuation coefficients of SAW to be $0.62{\sim}0.75dB/mm$(from IDT1, 20.8 MHz), and $0.60{\sim}0.72dB/mm$(from IDT2, 14.5 MHz), $0.83{\sim}1.28dB/mm$(from the wedge type), respectively.

  • PDF