• Title/Summary/Keyword: 월경 주기

Search Result 73, Processing Time 0.016 seconds

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

Androstendione and Testosterone Concentracions in Follicular Fluid in Hyperstimulated Menstrual Cycles (과배란 유도 월경주기중 난포액내 Androstendione 및 Testosterone 농도에 관한 연구)

  • Lee, Jin-Yong;Yoon, Bo-Hyun;Kim, Jung-Goo;Moon, Shin-Yong;Chang, Yoon-Seok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1986
  • Follicular flxid (FF) and their matched oocytes were obtained from 58 follicles of 27 women who underwent an in vitro fertilization (IVF) procedure with ovarian hyperstimulation by clomiphene citrate(n=8), hMG(n=9),FSH/hMG(n=10). Follicular aspiration was performed 36 hours after human chorionic gonadotropin administration. The concentcation of androstendione (ADD), testosterone (T) was correlated with hyperstimulation regimens, the morphology of the oocyte-corona-cumulus complex (OCCC), oocyte fertilization, and the incidence of pregnancy after embryo transfer. The results were as follows. 1. According to hyperstimulation regimens, there was no significant differance in FF ADD and T concentrations of the similar morphology of OCCC. 2. In clomiphene-treated and FSH/hMG-treated cycles, FF ADD concentrations of preovulatory oocytes were 43.09${\pm}$9.53 ng/ml and 59.46${\pm}$9.09 ng/ml, those of immature occytes were 96.98${\pm}$16.55 ng/ml and 116.13${\pm}$36.81 ng/ml, those of atretic oocytes were 246.5 ${\pm}$9.25 ng/ml and 634.25${\pm}$9.25 ng/ml respectively, reflecting the significant relationship between FF ADD level and morphologic maturity of OCCC (p<0.05). But in hMG-treated cycles, such relationship was not found (p>0.1). In clomiphene-treated and FSH/hMG-treated cycles, FF T concentrations of preovulatory oocytes were 11.37${\pm}$2.38 ng/ml and 11.68${\pm}$1.73 ng/ml respectively which were significantly lower than those of atretic oocytes (25.1${\pm}$7.50 ng/ml and 23.25${\pm}$0.95 ng/ml respectively) (p<0.05). But in all cycles, FF T concentrations of immature oocytes were not significantly different from those of preovulatory oocytes, artetic oocytes (p>0.1). 3. In hMG-treated and FSH/hMG-treated cycles, FF ADD concentrations of fertilized oocytes were 32.43${\pm}$4.09 ng/ml and 42.61${\pm}$4.82 ng/ml respectively which were significantly lower than those of non-fertilized oocytes (72.18${\pm}$17.31 ng/ml and 108.09${\pm}$17.32 ng/ml respectively) (p<0.05), but in clomiphene-treated cycles there was no significant difference (p>0.1). In FSH/hMG-treated cycles, FF T concentration of fertilized oocytes was 7.33${\pm}$1.06 ng/ml which was significantly lower than that of non-fertilized oocytes (20.3${\pm}$6.21 ng/ml) (p>0.02), but in clomiphne-treated and hMG-treated cycles there was no significant difference (p>0.1). 4. In all cycles FF ADD and T concentrations did not correlated with the success of pregnancy after embryo transfer. Above results suggested that FF ADD and T may play an important role in oocyte maturation and fertilization, but their relationship with the success of psegnancy was not found.

  • PDF

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF