• Title/Summary/Keyword: 원형 개구부

Search Result 20, Processing Time 0.025 seconds

Seismic Performance of Shear Dominant Hybrid Steel Link Beam with Circular Web Opening (원형 개구부가 있는 전단지배 하이브리드 강재 연결보의 내진성능)

  • Lim, Woo-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.37-48
    • /
    • 2018
  • Cyclic loading tests for shear dominant hybrid steel link beams with circular web openings were performed to evaluate the seismic performance. Four half-scaled specimens with bolted connections were tested. The test parameter is a diameter of the web opening, i.e., shear strength ratio ($V_{pw}/V_p$) of the link beam and presence of top-seat angles. Using test results, adequate design shear strength of link beam was finally suggested. Test results showed that when the shear capacity is less than half of the plastic shear strength, seismic performance was improved due to mitigation of pinching under reversed cyclic inelastic deformations.

An Analytic Solution of a Circular Aperture Antenna with a Feed Transition (급전부에 전이 구조가 있는 원형 개구면 안테나의 엄밀한 해석 방법)

  • Lee Haeng-Seon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.982-988
    • /
    • 2005
  • An analytic solution of circular aperture antenna with a feed transition is presented using a hybrid method of generalized scattering matrices and integral transform. The method can give an analytic solution to antennas with integrated filters or mode converters, etc. Scattering matrices and integral transform techniques are combined to accommodate discontinuities connected between an aperture and a feed waveguide, and radiated field from the aperture. The method gives radiation fields as well as return losses of the antenna.

Circular Dual Mode Horn Antenna(CDMHA) with Modified Aperture to Improve E/H-Plane Radiation Pattern Symmetry (E/H 평면 방사 패턴 대칭성 향상을 위해 개구면이 변형된 원형 이중 모드 혼 안테나)

  • Kim, Jae Sik;Yoon, Ji Hwan;Yoon, Young Joong;Lee, Woo-Sang;So, Joon-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.502-507
    • /
    • 2013
  • In this paper, a circular dual mode horn with modified aperture is proposed to improve a E/H-plane radiation pattern symmetry of a conventional oversized circular dual mode horn. The proposed antenna consists of a feeding section, a mode generation section and a phase matching section which has aperture shape transition from circle to ellipse or rectangle to improve a E/H-plane radiation pattern symmetry. To compare the performances between the proposed antenna and the convenional circular dual mode horn, the conventional circular dual mode horn and the proposed circular dual mode horn with rectangular aperture are fabricated and researched at 15 GHz. The measured results show that the conventional circular dual mode horn has 3.394 dB difference while the proposed antenna has only 0.539 dB difference between E and H-plane radiation patterns within the -11 dB beamwidth($53^{\circ}$) which is required beamwidth of the feed horn for the maximum aperture efficiency where f/d ratio of reflector antenna is 1.

Cyclic Vehavior of composite Beams with Double-Circular Web Openings (쌍원형 개구부를 가진 합성보의 이력거동)

  • 김원기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.162-169
    • /
    • 1999
  • Intentionally weakened girders near the beam-to-colum connection lead ductile failures at the weakened points prior to potential brittle failure at the connection points subjected to strong earthquake. Recent research investigated cyclic behavior of composite beams with a rectangular web opening and find out ductile failure of such beams due to plastic hinge formation of T-section at the four corners of the rectangular opening. But eventual failures of T-sections are resulted from local buckling of T-section having a narrow stem and a narrow bound of plastic hinge formation. This continuing research proposes double-circular opening instead of rectangular one in ofter to improve energy dissipation capacity as well as composite beam strength, Experimental test of two specimens was carried out and its results are compared with those of nonlinear finite element analyses

  • PDF

Transmission Cross Section of the Small Aperture in an Infinite Conducting Plane (도체 평판에서 소형 개구의 투과 단면적)

  • Ko, Ji-Hwan;Park, Soon-Woo;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.300-306
    • /
    • 2019
  • Transmission cross section(TCS) is described analytically as $2G{\lambda}^2/4{\pi}$ irrespective of the aperture shapes for various transmission resonant apertures, such as small ridged circular or H-shaped, U-shaped, or Jerusalem cross-shaped apertures in an infinite thin conducting plane. The proposed expression is validated by comparison with the numerical results obtained from the method of moments(MOM). The TCS characteristics of the transmission resonant cavity structure in a thick conducting plane are also studied and the equivalence between the two small aperture structures is reported from the viewpoint of transmission efficiency.

Structural Behavior of Beam-to-Column Connections of Rectangular CFT Structures having Different Diaphragm Opening (콘크리트충전 각형강관구조의 다이아프램 개구부 형상에 따른 기둥-보 접합부 구조적 거동)

  • Kim, Ki Hoon;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.289-298
    • /
    • 2015
  • The steel tube of Concrete-Filled Tube(CFT) confines the concrete and the concrete restrains the buckling of the tube, The objective of this study is to investigate the influences of the opening shape of the through diaphragm in case of the rectangular CFT column-to-beam connection through the structural experiment. The experiment results are compared with analysis results obtained by using the FEM program. These results are shown that strength of the rectangular CFT column-to-beam connection have similar structural performance regardless of the opening shape if opening areas of the through diaphragm are same. Also in case the connection area/shape of the through diaphragm and the flange of H-beam are similar, it was ascertained that the bending stress occurred at the beam can be transferred to the column through the diaphragm.

A Study on the Flow Coefficient of Compartment Fire (건물화재시 개구부의 흐름계수에 관한 연구)

  • 허만성
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.19-27
    • /
    • 1996
  • The objective of this research is to study on the upper layer temperature, interface height and flow regime in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The upper layer temperature and the Interface height were relatively well agreed with the experimental results when the flow coefficient at the opening was 0.65-0.8 for the rectangular trashcan, 0.65-0.9 for the circular trashcan and chair, and 0.7-0.9 for the carpet, sofa, mattress and wardrobe. The interface heights for the seven furniture fires were around 1[m] maintaining steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25[m]-0.75[m] from the floor. The flow regime at the opening was filling and buoyant for the distributed fire, and for the concentrated fire it was filling and then quickly changed to flow, and the flow period was long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the contact surface area with air. The time required to come down around 1[m] was within 1-3 minutes.

  • PDF

Dynamic Test and Analysis of Multilevel Post-tensioned PSC Girder with Holed Web (중공부가 있는 다단계 긴장 PSC 거더의 동특성 실험 및 해석)

  • Park, Bong-Sik;Cho, Jae-Yeol;Han, Man-Yeob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.11-12
    • /
    • 2010
  • PSC girder with holed web have several benefits. Most of all placing tendon anchorage in the holes can make prestressing forces be loaded stepwise. In addition it can reduce the self-weight of the beams and increase the span length of beams. And holed web might minimize the interference of view. In this study, a 50-meter long full scale multilevel post-tensioned PSC girder was fabricated and modal test was carried out. In order to obtain precise frequency response, vibration exciter was placed at the middle of the girder and excited with several frequencies. Natural frequency and damping ratio were evaluated from FFT and PSD using the obtained frequency response and compared with numerical analysis result.

  • PDF

Filling via hole in Si-wafer for 3 Dimensional Packaging (3차원 실장을 위한 Si-wafer의 via hole 딥핑 충전)

  • Hong Seong-Jun;Lee Yeong-U;Kim Gyu-Seok;Lee Gi-Ju;Kim Jeong-O;Park Ji-Ho;Jeong Jae-Pil
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.227-229
    • /
    • 2006
  • 3차원 실장을 하기 위해서 딥핑 방법으로 전기적 신호를 전달할 수 있는 비아를 가진 실리콘 웨이퍼를 제작하였다. 레이저를 이용하여 실리콘 웨이퍼에 개구부가 원형에 가까운 관통 홀을 형성하였다. 관통 홀의 벽에 도금 방법으로 시드 층을 형성하였다. 관통 홀의 충전 금속은 Sn-3.5Ag-0.7Cu 솔더를 사용하였다. 딥핑 방법으로 시드 층과 솔더 사이의 확산 현상 이용하여 전기적 신호를 전달 할 수 있는 비아를 형성하였다. 비아 내부에 일부 기공과 크랙이 발견되기도 했으나 딥핑 방법을 통해서 빠른 시간 내에 비아를 가진 실리콘 웨이퍼를 제작 할 수 있었다.

  • PDF

Design and Full Size Flexural Test of Spliced I-type Prestressed Concrete Bridge Girders Having Holes in the Web (분절형 복부 중공 프리스트레스트 콘크리트 교량 거더의 설계 및 실물크기 휨 실험 분석)

  • Han, Man Yop;Choi, Sokhwan;Jeon, Yong-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.235-249
    • /
    • 2011
  • A new form of I-type PSC bridge girder, which has hole in the web, is proposed in this paper. Three different concepts were combined and implemented in the design. First of all, a girder was precast at a manufacturing plant as divided pieces and assembled at the construction site using post-tensioning method, and the construction period at the site will be reduced dramatically. In this way, the quality of concrete can be assured at the manufacturing factory and concrete curing can be well controlled, and the spliced girder segments can be moved to the construction site without a transportation problem. Secondly, a numerous number of holes was made in the web of the girder. This reduces the self-weight of the girder. But more important thing related to the holes is that about half of the total anchorages can be moved from the girder ends into individual holes. The magnitude of negative moment developed at girder ends will be reduced. Also, since the longitudinal compressive stresses are reduced at ends, thick end diaphragm is not necessary. Thirdly, Prestressing force was introduced into the member through multiple stages. This concept of multi-stage prestressing method overcomes the prestressing force limit restrained by the allowable stresses at each loading stage, and maximizes the magnitude of applicable prestressing force. It makes the girder longer and shallower. Two 50 meter long full scale girders were fabricated and tested. One of them was non-spliced, or monolithic girder, made as one piece from the beginning, and the other one was assembled using post-tensioning method from five pieces of segments. It was found from the result that monolithic and spliced girder show similar load-deflection relationships and crack patterns. Girders satisfied specific girder design specification in flexural strength, deflection, and live load deflection control limit. Both spliced and monolithic holed web post-tensioned girders can be used to achieve span lengths of more than 50m with the girder height of 2 m.