• Title/Summary/Keyword: 원형파형강판

Search Result 7, Processing Time 0.026 seconds

A Study on Shear and Flexural Performance Evaluation of Circularly Corrugated Plate (원형 파형강판의 전단 및 휨 성능평가에 관한 연구 -전단 및 휨강도 설계식 제안-)

  • Moon, Seong Hwan;Oh, Sang Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.455-470
    • /
    • 2015
  • This research suggest method to calculate more accurate shearing and bending force on corrugated steel plate that it is produced domestically. This research analyze limitation of former formula on domestic design standard and existing research. In addition The strength calculation formula on corrugated steel plate was proposed according to result of the experiment and FEM analysis. In this study, the result that compare experiment with analysis using the proposed shear buckling coefficient and limit width to thickness ratio indicate similar behavior. As the result of the research, It is judged that the structural member design and performance evaluation of the corrugated steel plate was conveniently applied.

The Shear Strength Evaluation of Circularly Corrugated Steel Plates (원형 파형 강판의 전단좌굴강도 산정)

  • 한택희;임남형;김종헌;강영종
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.281-286
    • /
    • 2001
  • 최근, 경제적 이점과 전단강도의 증가효과로 인하여, 파형 Plate의 사용이 증가하여 있다. 일반 Plate에 대해서는 현재 거의 모든 시방서에 설계기준이 제시되어 있으나, 파형 Plate의 전단강도에 대한 규정은 제시되지 않은 실정이다. 따라서 설계자가 파형 Plate의 여러 기하 조건에 따른 전단강도의 관계를 알아보았으며, 수치해석에는 8절점 박판 쉘요소를 사용했다. 수치해석을 통하여 파형 Plate에 있어서 파형의 크기, 곡률, 파형 Plate의 두께에 따라 전단강도를 결정할 수 있는 식을 제안하였으며, 제안식은 파형 Plate가 일반 Plate에 비해 상당히 큰 전단강도를 갖는다는 것을 보여준다.

  • PDF

Centrifugal Model Test on Behavior of Underground Corrugated Steel Plate with Compaction Degree (다짐도에 따른 지중파형강판의 거동에 대한 원심모형실험)

  • Heo, Yol;Kwon, Seonuk;Kim, Hongjong;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.83-90
    • /
    • 2011
  • A series of centrifugal model test was conducted to investigate the distribution of vertical earth pressure on circular ductile underground corrugated steel plate waterway culvert with considering the compaction degree of the backfill in the high landfilled embankment section. The compaction degree of backfill was varied to 80, 85, 90, and 95% at the 53g-level gravity considering the similarity of the site. As a result of this test, the load reduction factor by the arching effect of the top of corrugated steel plate showing ductile behavior nearly agreed with the load reduction factor according to the compaction degree of backfill specified in the AISI(2002) design method. The vertical earth pressure measured at the top of the corrugated steel plate was linearly decreased as the compaction degree increased. The greater the compaction degree of backfill was, the greater the reduction of surface loading on the top of the corrugated steel plate by arching effect. The load decreased by arching effect on top of the corrugated steel plate was transferred to the side backfill of the corrugated steel plate(EP 1) and the outside of backfill(EP 3).

Numerical Evaluation of Buckling Strength for High-Strength Corrugated Steel Structures (고강도 원형 지중강판 구조물의 좌굴성능에 대한 수치적 평가)

  • Choi, Dongho;Cho, Sunkyu;Park, Sangil;Moon, Eunkyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.75-88
    • /
    • 2006
  • This paper evaluates the feasibility of use of high-strength steel for soil-metal corrugated steel structures. Two specifications, the AASHTO(2004) and the CHBDC(2000), were compared and the scientific background of equations for the buckling stability in those specifications were investigated to figure out the governing factors for buckling strength of structures. Numerous finite element analyses for round-pipe type of soil-metal corrugated steel structures were carried out with considering the elastic-plastic relationship of a material and the geometrical non-linearity, as well as the various design variables, such as span length, depths of soil cover, section properties, tensile strength and backfill conditions. Buckling strength equation of the CHBDC(2000) is still valid and conservative for both normal and high-strength steel soil-metal corrugated steel structures, and the buckling strength increases with the use of hight-strengths steel.

  • PDF

Evaluation of Minimum Depth Criterion and Reinforcement Effect of the Soil Cover in a Long-span Soil-steel Bridge (장지간 지중강판구조물의 최소토피고 평가 및 토피지반 보강에 대한 수치해석)

  • 이종구;조성민;정현식;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.67-78
    • /
    • 2004
  • Soil-steel bridges are made of flexible corrugated steel plates buried in the well-compacted granular soil. One kind of possible collapses of these structures could be initiated by shear or tension failure in the soil cover subjected to vehicle loads. Current design codes provide the requirements for the minimum depth of the soil cover to avoid problems associated with soil cover failures. However, these requirements were developed for short span (less than 7.7 m) structures which are made of unstiffened plates of standard corrugation (150$\times$50 m). Numerical analyses were carried out to investigate the behavior of long span soil steel bridges according to thickness of the soil cover. The span of structures were up to 20 m and deep corrugated plates (381$\times$140 m) were used. The analysis showed that the minimum cover depth of 1.5 m could be sufficient to prevent the soil cover failure in the structures with a span exceeding 10 m. Additional analyses were performed to verify the reinforcement effect of the concrete relieving slab which can be a special feature to reduce the live-load effects. Analyses revealed that the bending moment of the conduit wall with a relieving slab was less than 20% of that without a relieving slab in a case of shallow soil cover conditions.

Structural Behavior of the Buried flexible Conduits in Coastal Roads Under the Live Load (활하중이 작용하는 해안도로 하부 연성지중구조물의 거동 분석)

  • Cho, Sung-Min;Chang, Yong-Chai
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.323-328
    • /
    • 2002
  • Soil-steel structures have been used for the underpass, or drainage systems in the road embankment. This type of structures sustain external load using the correlations with the steel wall and engineered backfill materials. Buried flexible conduits made of corrugated steel plates for the coastal road was tested under vehicle loading to investigate the effects of live load. Testing conduits was a circular structure with a diameter of 6.25m. Live-load tests were conducted on two sections, one of which an attempt was made to reinforce the soil cover with the two layers of geo-gird. Hoop fiber strains of corrugated plate, normal earth pressures exerted outside the structure, and deformations of structure were instrumented during the tests. This paper describes the measured static and dynamic load responses of structure. Wall thrust by vehicle loads increased mainly at the crown and shoulder part of the conduit. However additional bending moment by vehicle loads was neglectable. The effectiveness of geogrid-reinforced soil cover on reducing hoop thrust is also discussed based on the measurements in two sections of the structure. The maximum thrusts at the section with geogrid-reinforced soil cover was 85-92% of those with un-reinforced soil cover in the static load tests of the circular structure; this confirms the beneficial effect of soil cover reinforcement on reducing the hoop thrust. However, it was revealed that the two layers of geogrid had no effect on reducing the overburden pressure at the crown level of structure. The obtained values of DLA decrease approximately in proportion to the increase in soil cover from 0.9m to 1.5m. These values are about 1.2-1.4 times higher than those specified in CHBDC.

Demagnetization to Induce Vertical Magnetization in a Military Vessel (함정에 수직자화를 부여하기 위한 탈자)

  • Kim, Young-Hak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1109-1112
    • /
    • 2015
  • A milatary ship without degaussing coil has a vertical magnetization to compensate magnetization induced by the vertical magnetic field component of earth magnetic field during demagnetization process. Flash D is very useful to acquire vertical magnetization. However this is hard to predict vertical magnetization. This experiment was investicated on another method, which used the only vertical bias magentic field. The specimens were prepared by thin Zn coated steel sheet with a thickness of 0.15mm. The shapes of 3 specimes was rectangular, triangular and circular cylinders. These shapes were corresponded to the shapes of bow, mid and stern of a vessel. Through FEM analysis, the difference of magnetic signatures for these specimens was recognized and the residual magnetization curve was measured. magnetic field was generated by a solenoid coil and magnetic signature was measured by a magnetic field sensor. A linearity between a vertical bias magnetic field and a vertical manetzation existed and the vertical magnetization of a miltary vessel was predicted by the linearity.

  • PDF