Evaluation on Sulfate Attack for Concrete Structures of Nuclear Power Plants (원자력발전소 콘크리트 구조물의 황산염 침식 평가)

  • Lee, Jong-Suk;Moon, Han-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.169-176
    • /
    • 2004
  • The Mechanistic model, considering expansion stress, coefficient of diffusion etc. to time, is applied to predict the deterioration of concrete structures of the nuclear power plant(NPP) due to sulfate attack. Mix design for the test was three kinds of specified compressive strength 385, 280 and $210kgf/cm^2$ which are used to construct NPPs and cement was type I and V. The immersion test was performed with 10% $Na_2SO_4$ solution to cement type and strength for a year. The coefficient of diffusion on each concrete mix is calculated based on the results of immersion test, and it is used for predicting the sulfate attack of the concrete structures of NPP. The coefficient of diffusion of the target concrete ranged $0.5763{\sim}3.9002{\times}10^{-12}m^2/sec.$, and the sulfate attack rate of concrete structures of the NPP was predicted as 0.1~7.1 mm/year.

지반-구조물 상호작용을 고려한 축대칭 원전 구조물의 비선형 지진해석

  • 윤정방;최준성;김재민
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.333-338
    • /
    • 1996
  • 강진에 의한 원전구조물의 동적해석시 지반의 비선형특성은 반드시 고려해야 할 사항이다. 지반의 비선형특성은 지반-구조계의 동적응답을 구하는 과정에서 가장 중요한 요소중의 하나며 이를 고려한 비선형 지진해석은 일반적으로 매우 복잡하고 정해를 구하기가 매우 어려운 문제다. 본 연구에서는 비선형 해법으로 널리 사용되고 있는 등가선형화방법을 사용하여 계측결과가 있는 TEPSCO 비선형 지진문제를 해석하였으며 이 방법의 정확도와 적용성을 분석하였다. 아울러 축대칭기법을 사용하여 비선형지진해석을 수행할때의 문제점에 관해서도 검토하였다.

  • PDF

Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure (확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가)

  • 최인길;서정문
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.47-56
    • /
    • 2001
  • In order to assure the safety of NPP structures, margin of safety or conservatism is incorporated in each design step. Seismic risk evaluation of NPP structures is performed based on the realistic capacity and response of structure eliminated the safety margin and conservatism. In this study, the comparative study on the various evaluation methods of the inelastic energy absorption capacity was performed. The inelastic energy absorption capacity due to the nonlinear behavior of structures has significant effect on the results of seismic probabilistic risk assessment. And the comparison study of the HCLPF(high confidence of low probability of failure) values according to the inelastic energy absorption factors was performed. As a conclusion, the inelastic energy absorption factor of NPP containment structure is estimated about 1.5~1.75. It is essential to estimate the nonlinear behavior of structure and its ductility factor correctly for the seismic risk assessment.

  • PDF

Experimental Evaluation of Internal Blast Resistance of Prestressed Concrete Tubular Structure according to Explosive Charge Weight (프리스트레스트 콘크리트 관형 구조물의 폭발량에 따른 내부폭발저항성능에 관한 실험적 평가)

  • Choi, Ji Hun;Choi, Seung Jai;Yang, Dal Hun;Kim, Jang-Ho Jay
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.369-380
    • /
    • 2019
  • When a extreme loading such as blast is applied to prestressed concrete (PSC) structures and infrastructures for an instantaneous time, serious property damages and human casualties occur. However, a existing design procedure for PSC structures such as prestressed containment vessel (PCCV) and gas storage tank do not consider a protective design for extreme internal blast scenario. Particularly, an internal blast is much more dangerous than that of external blast. Therefore, verification of the internal blast loading is required. In this paper, the internal blast resistance capacity of PSC member is evaluated by performing internal blast tests on RC and bi-directional PSC scaled down specimens. The applied internal blast loads were 22.68, 27.22, and 31.75 kg (50, 60, and 70 lbs) ANFO explosive charge at 1,000 mm standoff distance. The data acquisitions include blast pressure, deflection, strain, crack patterns, and prestressing force. The test results showed that it is possible to predict the damage area to the structure when internal blast loading occurs in PCCV structures.

A Study on the Assessment of Chloride Penetration Due to Diffusion in NPP Concrete Structures (원전콘크리트 구조물의 확산에 의한 염소이온 침투평가에 관한 연구)

  • Kim, Do-Gyeum;Lee, Jang-Hwa;Kim, Ki-Beom;Lee, Ho-Jae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.404-405
    • /
    • 2011
  • 원전구조물의 방사성 폐기물 처분시설의 경우 지하수에 해수가 유입되어 콘크리트에 염소이온 침투가 발생할 수 있으며, 콘크리트 내부에 존재하는 인장철근의 부식에 의한 내구성 저하 및 수명 단축이 주된 문제가 된다. 본 논문에서는 원전콘크리트 구조물에서의 확산에 의한 염소이온 침투에 대한 수학적 모델을 제시하였다. 콘크리트 중의 염소이온의 침투는 콘크리트의 노출환경, 습윤상태에 따라 확산(Diffusion), 대류(Absorption), 전기적 이동(Migration)에 의해 발생한다. 이러한 조건을 모두 고려하여 제시한 방정식에 의해 염소이온의 침투를 예측할 수 있다.

  • PDF

Analysis of Extreme Flood for Nuclear Power Plant Site (원전부지의 방재대책 수립을 위한 극한홍수해석)

  • Keum, Ho Jun;Park, Jun-Hyeong;Heo, Jun Haeng;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.553-553
    • /
    • 2016
  • 2011년 3월 일본 후쿠시마에서 대지진과 쓰나미로 인하여 대규모의 경제적 피해와 생명에 위협을 준 원전사고가 발생하였다. 이처럼 국가주요시설인 원전부지의 사고위험은 다양한 원인으로 인해 늘 위협받고 있으며, 최근 기후변화로 인하여 단시간의 지역적인 집중호우와 예상치 못한 폭우가 빈번하게 발생하고 있는 상황에서 극한홍수로 인한 사고 또한 중요한 원인으로 인식되고 있다. 하지만 우리나라에서는 원전부지에 대하여 PMP 등의 이상강우 조건 하에서 수공학적 안정도 평가와 국가 주요시설물 부지의 침수해석기법의 개발은 아직까지 전무한 실정이다. 따라서 본 연구에서는 원전부지 내에 영향을 미치는 극한강우를 다양한 기법으로 산정하여 가장 큰 피해를 미치는 극한강우 사상을 도출하였다. 도출한 극한강우를 유역유출분석을 통해 실제 원전부지 내로의 유입 경계조건으로 고려하여 2차원 침수해석을 실시하였다. 2차원 침수해석을 위해 원전부지 내 주요시설물, 도로, 하수관망 및 구조물 등을 반영하여 지형자료를 구축하였으며, 유출분석을 통해 유입되는 극한홍수량 외에 원전부지 내로 내리는 직접 강우도 함께 고려하였다. 그 결과를 통해 원전부지 내 침수심 및 유속 분포 등의 침수정보를 제공할 수 있는 침수위험도를 작성하였다. 본 연구를 통해 원전부지 내의 극한강우 산정 및 그로인한 침수위험도 작성으로 원전부지의 방재대책 수립시 기초자료로써 제공될 수 있을 것으로 판단된다.

  • PDF