• Title/Summary/Keyword: 원심삽입법

Search Result 5, Processing Time 0.019 seconds

An experimental study on the dynamic teeth movement of 3 types of the insertion method of Precision-TPA for derotating the posterior teeth (Precision-TPA를 이용한 구치부 회전시 근심 및 원심삽입법에 따른 동적인 치아이동 양상에 관한 실험 연구)

  • Yang, Sung-Jae;Jung, Seong-Gweon;Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.425-433
    • /
    • 1999
  • Dr. Youn-Sic Chun and coworkers invented the new machine for getting information about the relative effectiveness of the orthodontic appliances and we named it Calorific machine. The author and colleagues used this machine to compare with tooth moving mechanism by 3 types of the insertion method of precision-TPA for derotating the posterior teeth. We measured the distance of tooth movement and found out the rotational center on the occlusal X-ray film and the tooth movement on the occlusogram and then processed paired t-test by SAS program, The results were as follows : 1. In the intermolar width, the mesial insertion method showed the loss oi distance, and the other methods(-distal insertion method, mesial expansion method-) showed the increase of distance. 2. In the arch length, the distal insertion method was exhibited as most recommandable way for increasing the arch length .3. The rotation center of the mesial insertion method for derotating the molar, was located between mesial pit and central pit of the lower End molar. And, in the distal insertion method, it was located between distal pit and distolingual cusp, and in the mesial expansion method was located at distal pit.

  • PDF

Three-dimensional finite element analysis on the effect of maxillary incisor torque (상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구)

  • Yoon, Hyun-Joo;Lim, Yong-Kyu;Lee, Dong-Yul;Jo, Yung-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.137-147
    • /
    • 2005
  • The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, $.022{\times}.028$ Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees ThHe findings of this study showed that the reaction force acting or the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied. labial crown and distal tipping and Intrusion of the incisors took place. and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used NiTi or TMA wire is desirable for torque control.

Postcardiotomy Ventricular Support with Biomedicus Pump (Biomedicus pump를 이용한 개심술후 심실보조)

  • Kim, Won-Gon;Lee, Chang-Ha;Kim, Ki-Bong;Ahn, Hyuk;Rho, Ryang-Joon
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1218-1222
    • /
    • 1996
  • The reported incidence of postcardiotomy cardiogenic shock not responding to conventional therapy is still 0.1 to 0.8%. For this group of patients, more aggressive form of circulatory support must be employed. Centrifugal pumps are a ventricular assist device most commonly used on this purpose, due to low cost and easy availability. Currently, however, clinical experience of centrifugal pumps as a ventricular assist device is rarely reported in Korea. From January 1992 to January 1996, 2986 patients underwent cardiac operations on cardiopulmonary bypass at Seoul National University Hospital. Refractory postcardiotomy cardiac failure requring ventricular support with a Biomedicus centrifugal pump developed in ten of these patients. There were eight men and two women, ranged in age from nine years to 77 years with a mean of 50$\pm$20 years. The primary surgical procedures consisted of isolated coronary revascularization in four patients, combined coronary revascularization and aortic valve replacement in two, aortic dissection repair in two, pulmonary embolectomy in one, and heart transplantation in one. Of the ten patients, five had left ventricular assistance, one had right ventricular assistance, and four had biventricular assistance. Duration of ventricular assistance ranged from 24 to 175 hours, with a mean of 76$\pm$51 hours. Seven patients were weaned from ventricular assistance, and four of them discharged. The causes of death for nonsurvivors were progressive cardiac failure in two patients and multiorgan failure, intractable ventricular fibrillation, irreversible brain injury, and mechanical problem, respectively, in the other four. Survival was not predicted by time on cardiopulmonary bypass, aortic cross-clamp time, or duration of ventricular support. Major complications included bleeding(7), renal failure(6), infection(3) and neurologic complication(2). These results indicate that a centrifugal pump can provide reasonably satisfactory short-term circulatory support.

  • PDF

A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE MOLAR ANCHORING SPRING(MAS) DURING RETRACTION OF THE MAXILLARY CANINE (상악견치 후방견인시 저항원 조절을 위한 MAS(Molar Anchoring Spring)의 초기 응력분포에 관한 광탄성학적 연구)

  • Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.341-348
    • /
    • 1996
  • The efficiency of maxillary canine retraction by means of sliding mechanics along an 0.016 continuous labial arch and an 0.009 inch in diameter with a lumen of 0.030 inch NiTi closed coil spring was compared with that using the same NiTi closed coil spring and Molar Anchoring Spring(MAS) which was designed by author. MAS was made of .017" X .025" TMA wire and was given 60 degree tip-back bend on the wire close to the molar tube. This study was designed to investigate molar and canine root control during retraction into an extraction site with continuous arch wire system. Two techniques were tested with a continuous arch model embedded in a photoelastic resin. A photoelastic model was employed to visualize the effects of forces applied to canine and molar by two retraction mechanics. With the aid of polarized light, stresses were viewed as colored fringes. The photoelastic overview of the upper right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows. 1. Higher concentration of compression can be seen clearly at the distal curvature of the canine and mesial curvature of the molar and premolar when NiTi closed coil spring was applied only, which means severe anchorage loss of the molar and uncontrolled tipping of the canine. 2. The least level compression was presented at the mesial root area of the molar and premolar, and mesial root area of the canine when NiTi closed coil spring and MAS were used simultaneously. Especially mesial alveolar crest region of the canine was shown moderate level of compression that means MAS can be used as a appliance for anchorage control and prevention of canine extrusion and uncontrolled tipping during canine retraction.

  • PDF

A study on the shear bond strengths of orthodontic brackets according to surface treatments and polymerizing techniques. (도재표면의 처리방법과 접착제의 중합방식에 따른 교정용 브라켓의 전단강도의 연구)

  • Kim, Young-Joo;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.445-456
    • /
    • 1999
  • As a result of increased education and communication, the field of orthodontics has recently been expanded to include a greater number of adult treatment procedures. With this increased demand for adult orthodontic treatment, a problem that frequently arises is the placement of appliances on teeth restored with porcelain. But conventional acid-etching is ineffective in the preparation of porcelain surface for mechanical retention of orthodontic attachments. Also, it is possible to damage on porcelain. The purpose of this study was to evaluate the effect of composite bonding materials and the porcelain surface treatment methods on shear bond strength, and to observe the porcelain fracture rates. To accomplish this purpose, this study was carried out with feldsphatic porcelain, Ceram II. Porcelain surface treatment methods were divided into intact glazed porcelain which had not treatment and surface roughening. Surface roughening by etching with Hydroluoric acid(HF), sandblasting with Microetcher II and compound treatment with etching and sandblasting. Bonding materials were Ortho-two and Transbond. All porcelain specimens were applicated with porcelain primer. 1. In comparision according to porcelain surface treatment, surface roughening groups by HF etching and sandblasting had higher shear bond than intact group. No significant difference was found in Transbond group. 2. Ortho-two group had the higher shear bond strength than that of Transbond group in B:.u etching and sandblasting. 3. E(Transbond. Intact)group had the lowest shear bond strength in all experimental group. The bond strength was higher than clinically successful bond strength. 4. Non-treated group had very higher porcelain rates than treated group. 5. This study indicates that porcelain surface-roughening may not be necessary to attachment of orthodontic brackets to porcelain surfaces.

  • PDF