• Title/Summary/Keyword: 원거리음원

Search Result 36, Processing Time 0.022 seconds

A Study on the Rectangular Distribution of far Field Sources in Equivalent Source Method (등가음원법에서의 직육면체형 원거리음원 배치에 관한 연구)

  • 백광현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.40-46
    • /
    • 2004
  • The equivalent source method (ESM) uses two groups of equivalent source positions. One group includes the first order images of the sound source inside the enclosure. The positions of the other group are usually on a spherical surface some distance outside the enclosure. A proper selection of the positions for the far field sources could greatly improve the performance of the modeling accuracy and reduce the number of the sources to achieve the required accuracy. This study uses optimally distributed far field source positions on the surface of enlarged version of the rectangular enclosure instead of using typical spherical distribution. Simulations using various sizes of the box shaped distribution are executed and optimal positions are searched using an optimization technique from the larger number of candidate positions. The results of using these far field source positions are compared and analyzed.

Simple closed-form solution for a single source estimation in mixed far-field and near-field conditions (원근 혼합환경에서 간단한 닫힌 형식을 이용한 단일 음원 위치 추정 기법)

  • Jung, Tae-Jin;Lee, KyunKyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • Based on correlation and least square method, a closed-form algorithm for estimating the location of mixed far-field and near-field source is presented using the Uniform Circular Array (UCA). Recently, for a homogeneous circular arrangement case, a correlation based closed-form algorithm is proposed to estimate 2-D angle (azimuth, elevation) and the extended algorithm is proposed to 3-D location (azimuth, elevation, range). These algorithms assume the far-field source or near-field source only. Therefore, for mixed source localization, the proposed algorithm estimates source location with the assumption of far-field source, and then estimates the range to distinguish the far-field from the near-field source. For both cases, numerical experiments have been performed, which confirmed the validity of the proposed algorithm.

Effect of Different Misfired Gun on Seismic Survey Quality (불발 음원에 따라 탄성파탐사 성능에 미치는 영향)

  • 유해수
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.159-162
    • /
    • 1998
  • 불발 음원에 따른 음원 배열의 빔 패턴 변화와 남극탐사자료에서 원거리장 파형 변화를 분석하였다. 원거리장 파형의 주신호 진폭은 전체 건 부피의 약 40%에 해당하는 음원들이 불발을 일으킬 경우, 탐사성능이 33% 정도 떨어지는 것으로 확인되었다. 같은 간격의 음원들이 불발 시에는 배열형태와 관계없이 길이 및 폭배열의 빔 폭이 동일하게 나타난다. 불발 음원의 부피가 증가됨에 따라 상대적으로 음파 에너지가 작아 지지만 빔 폭이 40$^{\circ}$ - 34$^{\circ}$로 좁아지는 경향을 나타낸다. 따라서 탄성파 탐사에서 필요로 하는 좁은 파형이 생성됨으로써 천부 지층탐사에 적합한 것으로 확인되었다.

  • PDF

Remote Sound Extraction Using Laser Doppler Interferometer (레이저 도플러 간섭계를 이용한 원거리 소리 추출)

  • Hwang, Jeong-hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.108-113
    • /
    • 2021
  • We propose and experimentally demonstrate a method of remote sound extraction using laser Doppler interferometry. The output frequency of a laser Doppler interferometer changes to be the same as the frequency of the acoustic wave from than object vibrated by the sound due to the Doppler effect. Based on this phenomenon, we measure the vibrational frequency of a remote target affected by a sound wave in real time, via laser Doppler interferometry. We track the peak frequency of the interferometer's output via appropriate signal processing, which confirms that the characteristics of the so detected wave are the same as that of the original sound source. We also confirm that the same method can retrieve the sound waves not only from remote sources of single tones, but from those of any sound.

Optimization of the Number and Position of Far Field Sources in Using the Equivalent Source Method (등가음원법에서의 원거리음원의 위치와 개수의 최적화 연구)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.743-750
    • /
    • 2003
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and nay include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. Typical ESM modeling uses two groups of equivalent source positions. One group includes the first order images of the source inside the enclosure. The Positions of the other group are usually on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal far field sources positions when using the equivalent source method. In general, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study. optimal far field source locations are searched using simulated annealing method for various radii of spheres where far field sources are located. Simulation results showed that optimally located sources with adequate distance away from the enclosure center gave better result than sources with even distribution even with a smaller number of far field sources.

Far-Field Sound Field Estimation from Near-Field Sound Field Data Using Boundary Collocation Method ; Decision of Optimum Points of Measurement (경계 배치법(Boundary Collocation Method)에 의한 근거리 음장 자료로부터 원거리 음장의 예측 ; 최적 측정점 개수의 결정)

  • 김원호;윤종락
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.31-37
    • /
    • 1999
  • This paper describes the far-field estimation using the near-field measurement data. Measurement in far-field region gives us the acoustical characteristics of the source but in general measurement is made in near-field such as acoustic water tank or anechoic chamber, so far-field acoustical characteristics of the source should be predicted from near-field data. In this case, the number of measurement points in the near field which relates to the accuracy of the predicted field and the amount of data processing, should be optimized. Existing papers say that measurement points is proportional to kL and depends on geometry and directivity of the source. But they do not give us any definite criterion for the required number of measurement points. Boundary Collocation Method which is one of the far-field prediction methods, is analyzed based on Helmholtz integral equation and Green function and it has been found that the number of measurement points is optimized as 0.54kL which is about one half of the existing results.

  • PDF

Study on Air Absorption Processing for Spatial Audio Rendering (공간음향 렌더링을 위한 공기흡음 처리에 관한 연구)

  • Daeyoung Jang;Yong Ju Lee;Jae-hyoun Yoo;Kyeongok Kang;Tae Jin Lee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.11a
    • /
    • pp.18-21
    • /
    • 2022
  • 본 논문에서는 6 자유도 공간음향 렌더링 기술 관련 음향객체의 거리감 인지에 중요한 공기흡음 감쇠 효과 처리에 있어, 현장의 음원과 음향 센서 사이의 거리인 녹음거리에 해당하는 공기흡음 감쇠가 기본적으로 포함되어 3kHz 이상의 고주파 성분이 감쇠된 음원이 렌더링에 사용되는 문제점을 해결하는 방법을 제시한다. 이 방법에 의하면 6 자유도 공간음향 콘텐츠에 메타데이터로서 녹음거리 파라메터를 포함시키고, 렌더링할 때 공기흡음을 적용하기 위한 음원과 청취자의 거리값에 녹음거리에 대한 보상을 적용함으로써, 음원의 공기흡음 감쇠 효과를 정확하게 수정 적용하여 음원의 음색을 모든 거리에서 실제에 가깝도록 제공할 수 있게 된다. 특히, 원거리 녹음이 불가피한 비행기, 천둥, 폭발음 등 원거리 녹음음원의 음색에 녹음거리에 의한 음원의 공기흡음 감쇠가 적지 않은 영향을 미치게 되는데, 녹음거리의 적용에 의한 제안한 방법에 의해 음원과 청취자의 거리값에 대한 음원의 음색이 고주파영역의 녹음거리에 의한 원치 않는 감쇠를 보상하는 효과를 확인할 수 있었다.

  • PDF

Calculation of Near and Far Acoustic Fields Due to a Spinning Vortex Pair in Free Field (자유흐름장 내의 회전하는 와류쌍에 의한 근거리 및 원거리 음장해석)

  • Koo Sam-Ok;Ryu Ki-Wahn;Lee Duck-Joo
    • Journal of computational fluids engineering
    • /
    • v.2 no.1
    • /
    • pp.29-36
    • /
    • 1997
  • 자유흐름장에 놓여 있는 회전 와류쌍을 음원으로 갖는 비정상 유동장에서 사극음원이 음장에 미치는 효과를 알아보기 위해 이차원 음장 수치해석을 시도하였다. 비압축성 유동장에 대한 비정상 수력정보를 기반으로 오일러식에서 교란 압축성 소음항을 도출하였다. 원거리 자유 경계면은 비반사 경계조건을 이용하여 매우 안정된 해를 얻을 수 있었다. 계산된 결과들은 MAE 방법과 비교하여 정확도를 입증하였다. 본 연구를 통해 비압축성 압력교란을 원천항으로 하여 물체가 존재하지 않는 경우에도 사극음원에 의한 음장을 수치적으로 계산이 가능함을 입증하였다.

  • PDF

Effect of Different Misfired Source on Seismic Survey Quality (불발 음원이 탄성파탐사 성능에 미치는 영향)

  • 유해수;장재경;양승진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.7
    • /
    • pp.75-79
    • /
    • 1999
  • The beam patterns of source array and changes in the far-field signatures are compared and analyzed each other in order to identify the seismic capability affected by the misfired source at the multi-channel seismic source array. In the primary pulse amplitude of far-field signature, the 66% of seismic capacity are sustained if approximately 40% of source are misfired among whole gun volume. When the sources with the same distances are misfired at the 154㎐, the beam width of the long- and wide-array which is identical regardless of arraying pattern. The beam width has a tendency to narrow now from 41 to 34 according to increase the volume of misfired source at the long-array beam pattern. Therefore, the source array of small volume are suitable for the shallow seismic survey because of producing adequate beam patterns with narrow beam width.

  • PDF

Far-Field Radiated Noise From Near-Field Measurement (근거리 음장 측정을 통한 원거리 음장 예측에 관한 스피커 실험)

  • Kim Tae-Jin;Son Keun-Young;Shin Hyun-Oak;Yoon Jong-Rak
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.125-128
    • /
    • 1999
  • 근거리음장 측정으로부터 원거리음장을 예측할 수 있는 이론적 모델 및 실험적 연구가 수행되고 있다. 본 논문에서 채택한 방법은 Helmholtz 적분식의 간단한 모델로써 단일주파수 코히어런트 음원의 근거리측정음장으로부터 원거리음장 예측이 가능한 기술이다. 이러한 단일 주파수, 코히어런트 음원의 원거리 수평방향지향성을 예측하기 위한 모델식 및 무향실에서 수행한 검증실험 결과를 소개한다 제안된 방법은 일반 소음원은 물론 잠수함 등의 수평방향 지향성의 예측에 적용가능하다고 판단된다.

  • PDF