Removal of Nutrients Using an Upflow Septic Tank(UST) - Aerobic Filter(AF) System (부패조와 호기성 여과공정을 이용한 영양염류 제거)

  • Park, Sang-Min;Jun, Hang-Bae; Bae, Jong-Hun;Park, Woo-Kyun;Park, Noh-Back
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.232-238
    • /
    • 2010
  • The objective of this study was to investigate a small sewage treatment system. This system was developed to improve a nitrogen and phosphorus removal efficiency and generate less solid using upflow septic tank(UST) - aerobic filter(AF) system. The UST equipped with an aerobic filter, the filter was fed with both raw sewage and recycled effluent from the UST to induce the denitrification and solid reduction simultaneously. Overall removal efficiencies of COD and total nitrogen(TN) were above 96% and 73% at recycle ratio of 200%, respectively. Critical coagulant dose without the biochemical activity was found to be 40 mg/L. Removal efficiency of total phosphorus(TP) in influent was above 90% by chemical and biological reactions. Although the phosphorus concentration was low under the high alkalinity in raw sewage, the pH value was unchanged by the coagulant dose.

Approximate SHE PWM for Real-Time Control of 2-Level Inverter (3레벨 인버터의 실시간 제어를 위한 근사화 SHE PWM)

  • 박영진;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.365-374
    • /
    • 1998
  • The SHE(Selected Harmonic Elimination) PWM scheme which eliminates specific lower order harmonics can generate h high quality output waveforms in 3-level PWM inverters. However. its application has limited since SHE switching a angles cannot be calculated on-line by a microprocessor-implemented control system. Based on off-line optimization. in which multiple SHE solutions were found and analysed for 2 to 5 switching angles per quarter in the 3-level SHE PWM pattern. this paper presents an algebraic algorithm for an ordinary microprocessor to calculate approximate SHE S switching angles on-line with such high resolution that it makes no practical difference between the accurate and the a approximate SHE switching angles. By employing the variable of the dc-link voltage Vdc' the proposed SHE PWM p pattern can ideally compensate the dc input fluctuation together with selected harmonics eliminated.

  • PDF

Anaerobic Digestion Biochemical Sludge Produced from Municipal Sewage Treatment Process (하수처리시설에서 발생된 약품 잉여슬러지의 혐기성 소화 특성)

  • Cho, Sang Sun;Kang, Ho;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.561-569
    • /
    • 2014
  • This study was carried out to get the characteristics of anaerobic digestion for chemical/biological sludge produced from municipal sewage treatment plant for phosphorus. Anaerobic mesophilic batch tests showed that the ultimate biodegradability of waste activated sludge showed 31%, PACl sludge 24%, Alum sludge 26%, respectively. At the S/I 1.0, 75% of total biodegradable volatile solids (TBVS) of waste activated sludge was degraded with an initial rapid decay coefficient, k1 of $0.1129day^{-1}$ and 74% of TBVS of PACl sludge with k1 of $0.0998day^{-1}$, and 76% of TBVS of Alum sludge with k1 of $0.1091day^{-1}$ for 20 days. During the operation of SCFMRs, the 3 reactor (Control, PACl, Alum) pH maintained 6.7~7.0 and the reactor alkalinity maintained 1,800~ 2,200 mg/L as $CaCO_3$. The average biogas production rates of SCFMRs fed with PACl sludge and Alum sludge were 0.089 v/v-d and 0.091 v/v-d, respectively, which was 27~28% lower than that of the control (0.124 v/v-d) at an HRT (hydraulic retention times) of 20 days. And the methane content during the operation ranged 70~76% in 3 reactor. The average TVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 19.6% and 19.9%, respectively, at an HRT of 20 days, which showed 4% lower than that of the control (23.8%). The average BVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 25.8% and 26.9%, respectively, at an HRT of 20 days, which was 8~9% lower than that of the control (34.5%).

Treatment of Garbage Leachate with Two-phase Anaerobic Digestion Coupled with Ultra Filtration (막결합형 2상 혐기성 소화 공정을 이용한 음식물 탈리액 처리)

  • Lee, Eun-Young;Kim, Hyung-Kuk;Giang, Luu Thi Thuy;Bae, Jae-Ho;Bae, Young-Shin;Won, Jong-Choul;Lee, Jae-Hoon;Park, Seung-Kyun;Cho, Yong-Wan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.997-1006
    • /
    • 2009
  • Organic removal efficiency and methane production rate, a feasibility of power generation from biogas, and the optimum conditions for membrane operation were evaluated for the pilot scale (5 tons/day) two-phase anaerobic digestion coupled with ultra filtration (TPADUF) system fed with garbage leachate. The TPADUF system is consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. When garbage leachate with 150 g/L of TCOD was fed to the TPADUF up to organic loading rate (OLR) of 11.1 g COD/L/d, the effluent TCOD was lower than 6 g/L and the average removal efficiencies of TCOD and SCOD were higher than 95%. The methane composition of the gas was 65%, and the methane yield was 39 $m^3/m^3$ garbage leachatefed, 260 $m^3$/tons $COD_{added}$, or 270 $m^3$/tons $COD_{removed}$, even there was some gas leak. The power production per consumed gas was 0.96 kWh/$m^3$ gas or 1.49 kWh/$m^3$ methane. This lower power production efficiency mainly due to the small capacity of gas engine (15 kW class). The membrane was operated at the average flux of 10 L/$m^2$/hr. When the flux decreased, washing with water and chemical (NaOCl) was conducted to restore the flux. In the TPADUF system, optimum pH could be maintained without alkali addition by recycling the membrane concentrate or mixed liquor of the methanogenic digester to the acidogenic reactor. Also, partial production of methane in the acidogenic reactor had a positive effect on lowering the OLR of the methanogenic reactor.

Purification Efficiency of Slop & Plane Water Treatment Part of SRT System Using Eco-Concrete (Eco-Concrete를 이용한 SRT System의 사면수처리부와 평면수처리부의 정화효율분석)

  • Jang, Won-Geun;Park, Jae-Young;Choi, I-Song;Chang, Jun-Young;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1860-1864
    • /
    • 2006
  • 본 연구는 강우시 발생되는 강우유출수와 합류식하수관거월류수에 의해 하천으로 유입되는 오염부하를 저감시키기 위한 공법으로, 고수부지 및 제방사면부와 둔치부를 형상화하여 pilot를 제작하였고, 연속적으로 시운전을 한 SRTS(Stormwater Runoff Treatment System)에 관한 것이다. SRT system 내부의 사면수처리부와 평면수처리부에는 다공성 콘크리트를 충진하였다. system 상부에는 식생을 조성하여 뿌리가 수면에 닿아 영양물질을 흡수하는 목적으로 사면수처리부와 평면수처리부에 각각 정육각형과 직사각형인 식생포트를 탈.부착이 가능하도록 고안하였다. 내부에서는 토양과 수처리조 사이에 연결관을 부착하였고, 모세관현상에 의해 토양이 수분을 흡수하도록 구성하였다. pilot plant는 유입부, 사면 수처리부, 평면 수처리부, 유출부로 나누었다. 유입부는 유입펌프와 V-notch로 구성하였고, 유입펌프는 2대를 설치하여 1시간 간격으로 연속적 유입으로 유량조절이 가능하도록 상호교대 운전을 하였다. 평면 수처리부$(W(1.0m){\times}(L(2.4m){\times}H(0.6m))$는 장방형의 접촉산화조로서 하부에 슬러지 침전 및 저류를 위한 hopper를 설치하여 슬러지의 원활한 수집 및 인발이 가능하도록 하였다. 유출부는 사각weir를 설치하였다. 강우유출수의 pH는 $7.27{\sim}7.92$이고, DO농도는 $7.12{\sim}7.88mg/l$로 관측되었다. 2차처리수의 pH는 평균7.4이고 DO농도는 최저 4.5 mg/l에서 최고 8.9 mg/l로 평균 6.8 mg/l로 관측되었다. 또한 강우유출수의 유입수의 T-N, T-P 농도는 각각 $17.5{\sim}22.5mg/l,\;8.9{\sim}11.4mg/l$의 범위이고, 2차 처리수의 유입수의 T-N, T-P 농도와 유사하였다.적인 방법론을 제시할 수 있을 것으로 사료된다.첨두홍수량을 저류하기 위해서 상대적으로 넓은 저류면적이 필요한 것으로 나타난다. 대등한 수위감소값의 홍수저감효과를 발휘하기 위해서 본 연구에서는 On-Line 저류지 면적은 Off-Line 저류지에 비 두배 이상이 필요한 것으로 보여졌다.들에 관한 정보는 종종 현장관측에서 조차 무시되는 경우가 많다. 이에 본 연구에서는 수질모형의 매개변수 중 특히 수리특성에 관련된 매개변수들이 수질에 미치는 영향을 파악하는 것을 목적으로 하고 있다. 이를 위해 적용된 수질모형은 QualKo를 사용하였으며, 대상 하천은 낙동강 본류 경남구간 시점 부근인 회천 합류 전부터 낙동강 본류 경남구간 종점 부근인 밀양강 합류 전까지의 경남 오염총량관리 기본계획 시 구축된 모형 매개변수를 바탕으로 분석을 수행하였다. 일차오차분석을 이용하여 수리매개변수와 수질매개변수의 수질항목별 상대적 기여도를 파악해 본 결과, 수리매개변수는 DO, BOD, 유기질소, 유기인 모든 항목에 일정 정도의 상대적 기여도를 가지고 있는 것을 알 수 있었다. 이로부터 수질 모형의 적용 시 수리 매개변수 또한 수질 매개변수의 추정 시와 같이 보다 세심한 주의를 기울여 추정할 필요가 있을 것으로 판단된다.변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전략이고, 이 전략의 유용성은 투자자가 설정한 투자기간보다 더욱 긴 분석기간의 주식가격정보에 의하여 최대한 발휘될 수 있음을 확인하

  • PDF

A Case Study on the Effective Liquid Manure Treatment System in Pig Farms (양돈농가의 돈분뇨 액비화 처리 우수사례 실태조사)

  • Kim, Soo-Ryang;Jeon, Sang-Joon;Hong, In-Gi;Kim, Dong-Kyun;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.99-110
    • /
    • 2012
  • The purpose of the study is to collect basis data for to establish standard administrative processes of liquid fertilizer treatment. From this survey we could make out the key point of each step through a case of effective liquid manure treatment system in pig house. It is divided into six step; 1. piggery slurry management step, 2. Solid-liquid separation step, 3. liquid fertilizer treatment (aeration) step, 4. liquid fertilizer treatment (microorganism, recirculation and internal return) step, 5. liquid fertilizer treatment (completion) step, 6. land application step. From now on, standardization process of liquid manure treatment technologies need to be develop based on the six steps process.

Microwave Irradiation as a Way to Reutilize the Recovered Struvite Slurry and to Enhance System Performance (회수된 MAP 슬러리의 재이용과 공정효율 향상을 위한 도구로서의 극초단파 조사)

  • Cho, Joon-Hee;Lee, Jin-Eui;Ra, Chang-Six
    • Journal of Animal Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.337-342
    • /
    • 2009
  • The feasibility of reutilization of magnesium ammonium phosphate (MAP) or struvite slurry recovered from the process through microwave irradiation was studied in this experiment. For this purpose, 4 different operations were performed with or without Mg source addition and different levels of MAP recycled in a batch reactor. Dissolution rate of MAP, ${NH_4}^+$ elimination pattern and physicochemical changes of MAP during microwave irradiation were also studied. The result showed that only 33% orthophosphate ($PO_4-P$) and 27% $NH_4-N$ removal occurred without adding any external Mg source (run A), whereas 87% $PO_4-P$ and 40% $NH_4-N$ removed when 1.0 M ratio of $MgCl_2$ (run B) was added based on $PO_4-P$ in influent. Although the addition of 1.0 molar ratio of microwave irradiated MAP (Run C) removed lower $PO_4-P$ and $NH_4-N$ than 1.0 M $MgCl_2$ (run B), $PO_4-P$ removal was double when compared with no Mg addition (run A). Addition of half MAP and half $MgCl_2$ (run D) showed the similar removal efficiency (88% $PO_4-P$ and 35% $NH_4-N$) with sole $MgCl_2$ addition (run B). Based on these results, the reutilization of MAP irradiated by microwave would be a feasible way to enhance the removal efficiencies of N and P, as well as curtail the Mg chemical usage. Track study showed that $NH_4-N$ gradually increased at initial stage of microwave irradiation of MAP, and then started eliminating from liquor as temperature increased over $45^{\circ}C$. Dissolution rate of ${PO_4}^{-3}$ during microwave irradiation was proportional to the initial MAP concentration, having $0.0091x^{0.6373}$ mg/sec. It was found from the scanning electron microscope (SEM) study that physical structure of MAP crystal started breaking down into small cube granules within very short time by electromagnetic vibration force during microwave irradiation and then gradually melted down into solution.

A Study on the Odor Characteristics and Identification of Microbial in Biological Swine Manure Treatment Process by Bioreactor (생물반응기를 도입한 돈분뇨의 생물학적 처리공정에서 악취발생 특성 및 미생물동정에 관한 연구)

  • Ko, Joon-il;Park, Gui-hwan;Bae, Ju-soon;Oh, Gil-young;Chung, Seon-yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.526-532
    • /
    • 2015
  • A bioreactor filling with pellets and stones was equipped to the swine manure treatment system, which is expected to emit high concentration of odor in the process of the organic wastewater treatment system, and in comparison with the activated sludge process as the control process, the reactor operation state, treatment water quality and odor emission concentration were measured. The reactor using the bioreactor proved to be much more stable in the bubble condition, treatment water transparency, etc, and BOD removal efficiency was also much better. The removal efficiency of T-N and T-P, however, showed little difference in the two reactors. Odor, as a result of examining $NH_3-N$, $NH_3$ concentratio, and complex odor, was 4 times to 24 times less emitted in the system using bioreactor than in the activated sludge system. $H_2S$, methyl mercaptan, dimethyl sulfide, and dimethyl disulfide were not found or were found in only 5 ppbs in each reactor and showed little difference between the two reactors. In the bioreactor process, Bacillus sp./ Pseudomonas sp. species were mainly found and in the activated sludge process, acterium sp. Chryseobacterium sp. species were mainly found.

Nutrient Recovery from Sludge Fermentation Effluent in Upflow Phosphate Crystallization Process (상향류 인 결정화공정을 이용한 슬러지 발효 유출수로 부터의 영양소 회수)

  • Ahn, Young-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.866-871
    • /
    • 2006
  • The nutrient recovery in phosphate crystallization process was investigated by using laboratory scale uptlow reactors, adopting sequencing batch type configuration. The industrial waste lime was used as potential cation source with magnesium salt($MgCl_2$) as control. The research was focused on its successful application in a novel integrated sludge treatment process, which is comprised of a high performance fermenter followed by a crystallization reactor. In the struvite precipitation test using synthetic wastewater first, which has the similar characteristics with the real fermentation effluent, the considerable nutrient removal(about 60%) in both ammonia and phosphate was observed within $0.5{\sim}1$ hr of retention time. The results also revealed that a minor amount(<5%) of ammonia stripping naturally occurred due to the alkaline(pH 9) characteristic in feed substrate. Stripping of $CO_2$ by air did not increase the struvite precipitation rate but it led to increased ammonia removal. In the second experiment using the fermentation effluent, the optimal dosage of magnesium salt for struvite precipitation was 0.86 g Mg $g^{-1}$ P, similar to the mass ratio of the struvite. The optimal dosage of waste lime was 0.3 g $L^{-1}$, resulting in 80% of $NH_4-N$ and 41% of $PO_4-P$ removal, at about 3 hrs of retention time. In the microscopic analysis, amorphous crystals were mainly observed in the settled solids with waste lime but prism-like crystals were observed with magnesium salt. Based on mass balance analysis for an integrated sludge treatment process(fermenter followed by crystallization reactor) for full-scale application(treatment capacity Q=158,880 $m^3\;d^{-1}$), nutrient recycle loading from the crystallization reactor effluent to the main liquid stream would be significantly reduced(0.13 g N and 0.19 g P per $m^3$ of wastewater, respectively). The results of the experiment reveal therefore that the reuse of waste lime, already an industrial waste, in a nutrient recovery system has various advantages such as higher economical benefits and sustainable treatment of the industrial waste.

Evaluation of $^{14}C$ Behavior Characteristic in Reactor Coolant from Korean PWR NPP's (국내 경수로형 원자로 냉각재 중의 $^{14}C$ 거동 특성 평가)

  • Kang, Duk-Won;Yang, Yang-Hee;Park, Kyong-Rok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study has been focused on determining the chemical composition of $^{14}C$ - in terms of both organic and inorganic $^{14}C$ contents - in reactor coolant from 3 different PWR's reactor type. The purpose was to evaluate the characteristic of $^{14}C$ that can serve as a basis for reliable estimation of the environmental release at domestic PWR sites. $^{14}C$ is the most important nuclide in the inventory, since it contributes one of the main dose contributors in future release scenarios. The reason for this is its high mobility in the environment, biological availability and long half-life(5730yr). More recent studies - where a more detailed investigation of organic $^{14}C$ species believed to be formed in the coolant under reducing conditions have been made - show that the organic compounds not only are limited to hydrocarbons and CO. Possible organic compounds formed including formaldehyde, formic acid and acetic acid, etc. Under oxidizing conditions shows the oxidized carbon forms, possibly mainly carbon dioxide and bicarbonate forms. Measurements of organic and inorganic $^{14}C$ in various water systems were also performed. The $^{14}C$ inventory in the reactor water was found to be 3.1 GBq/kg in PWR of which less than 10% was in inorganic form. Generally, the $^{14}C$ activity in the water was divided equally between the gas- and water- phase. Even though organic $^{14}C$ compound shows that dominant species during the reactor operation, But during the releasing of $^{14}C$ from the plant stack, chemical forms of $^{14}C$ shows the different composition due to the operation conditions such as temperature, pH, volume control tank venting and shut down chemistry.

  • PDF