• Title/Summary/Keyword: 운전실

Search Result 313, Processing Time 0.025 seconds

Implementation and Experiment Result of Hardware-in-the-Loop Simulation(HILS) System for The Verification of ITER AC/DC Converter Control (ITER AC/DC Converter Control 검증을 위한 Hardware-in-the-Loop Simulation(HILS) System 구축 및 실험)

  • Suh, Jae-Hak;Oh, Jong-Seok;CHOI, Jungwan;SHIN, Hyun-Kook;Cha, Hanju;Park, In-Kwon
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.221-222
    • /
    • 2015
  • ITER AC/DC Converter의 부하는 초전도 코일이며 이에 필요한 컨버터는 총 6종류(2상한:TF, 4상한:PF, CS, VS, CCU/L, CCS)가 있다. 이중 VS 컨버터(${\pm}1050V$, ${\pm}22.5kA$)는 6대가 직렬로 접속되어 운전되고 CS 컨버터(${\pm}1050V$, ${\pm}4.5kA$)는 4대가 직렬로 접속되어 운전한다. 이들 컨버터용 제어기의 개발 단계에서 실 부하상태를 준비하는 것은 어렵기 때문에 $RTDS^{TM}$ (Real Time Digital Simulator)를 이용하여 제어 대상인 High Power 부분과 초전도 코일의 동적 시스템 모델을 HILS(Hardware-in-the-Loop Simulation)로 구축하였다. 본 논문에서는 HILS 구축에 대한 상세한 내용과 이를 활용하여 Control 시스템을 검증한 결과를 서술하였다.

  • PDF

Development of TRAIN for Accident Management (중대사고관리를 위한 훈련도구(TRAIN)의 개발)

  • Moo-Sung Jae
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.84-87
    • /
    • 2001
  • Severe accident management can be defined as the use of existing and alternative resources, systems, and actions to prevent or mitigate a core-melt accident in nuclear power plants. TRAIN (Training pRogram for AMP In NPP), developed for training control room staff and the technical group, is introduced in this paper. The TRAIN composes of phenomenological knowledge base (KB), accident sequence KB and accident management procedures with AM strategy control diagrams and information needs. This TRAIN might contribute to training them by obtaining phenomenological knowledge of severe accidents, understanding plant vulnerabilities, and solving problems under high stress.

  • PDF

Research of KNPEC-2 Simulator Upgrade(I) (원자력 교육원 #2 시뮬레이션 성능개선에 관한 연구(I))

  • 유현주
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.249-252
    • /
    • 2000
  • 원자력 교육원 #2(KNPEC-2) 시뮬레이터는 1980년도 중반에 웨스팅하우스에 의해 공급되어 계속 사용되어 오다가 현재 성능개선 연구가 진행 중이다. 이번 성능개선을 통해 기존의 컴퓨터 시스템(Gould MPX)와 소프트웨어의 전면 교체가 이루어지고 있으며 최적 계산 코드를 이용한 실시간 열수력 모델 (ARTS; Advanced Real-Time Thermal-Hydraulics Simulation) 개발 , 2-Group 3D 실시간 노심모델(REMARK ; REal Time Multigroup Advanced Reactor Kinetics)를 이용한 노심 주기개선 (Cycle Update) 가상현실 기술 등을 이용한 컴퓨터 교육지원 시스템(CATS: Computer Assister Training System)등 새로운 시도가 이루어지고 있으며 본 논문은 이러한 새로운 시도가 이루어지고 있으며 본 논문은 이러한 새로운 시도들 및 그 결과에 대해 기술하고 있다. 기준발전소(Reference Plant)인 영광 1호기 12주기의 노심모델로 주기개선(Cycle Update)을 위한 REMARK의 입력자료 생성을 위해 핵설계 전산체계인 APA(ALPHA-PHOENIX-ANC) 시스템의 출력으로부터 자동으로 REMARK 입력데이타를 생성하기 위한 GUI툴 개발하였다. 또 이를 이용하여 개발된 노심모델은 최적계산코드(RETRAn 3D) 의 열수력 해법을 이용하여 개발된 NSSS 열수력코드(ARTS) 와 결합(Integration) 되어 안정 및 과도 상태 시험에 사용되었으며 원자로 냉각재 펌프 정지등의 몇 가지 과도 시험 계산결과 기존 해석 결과와 잘 일치하였다 중앙제어실(MCR; Main Control Room)내의 운전원 행동만 훈련하도록 되어있는 기존시뮬레이터의 한계를 극복하기 위해 가상현실 (VR) 저작도구를 이용한 발전소 현장 내부를 표현하는 가상발전소 (Virtual Plant) 발전소 현장에 소재하여 기존 시뮬레이터의 모의한계 밖에 있던 패널을 표현한 가상판넬(Virtual Panel)등과 강의실에서 발전소 모의 훈련을 가능케 하기 위해 가상현실 기술을 이용한 컴퓨터 지원 교육훈력 시스템(CATS ; Computer Assister Training System)을 개발 중이며 일부 개발부분을 소개하였다.

  • PDF

A Study on Dynamic Characteristics Analysis of Spindle Unit for Two-for-One Twister (투포원 연사기용 스핀들 유니트의 동특성 해석에 관한 연구)

  • Kim, Gwang-Yeong;Kim, Jong-Su
    • 연구논문집
    • /
    • s.27
    • /
    • pp.127-139
    • /
    • 1997
  • Two-for-one twister is a kind of textile machine and makes special fancy yarn which is twisted two times per one revolution in order to increase tensile strength and wear resis-tance of yarn. Spindle mechanism has to be stable and continuous motion in high speed revolution, and then optimal design is necessary to analyze dynamic characteristics of spindle unit. Spindle unit is consist of blade and rotary disc that are cylindrical body of revolution. For analysis of the dynamic characteristics of spindle unit, transfer matrix method is used and a numerical code SPINDLE also. Torsion and natural bending frequency of the spindle unit are examined. Its displacement mode is studied in function of variable revolutions.

  • PDF

Abnormal High Vibration by the Accumulated Oil Carbide at the Exhaust Casing Bearing Air Seal of a Gas Turbine (가스터빈 EXHAUST 케이싱 베어링 AIR SEAL에서 오일 탄화물 축적에 의한 이상 진동)

  • Kim, Dong Kwan;Park, Sangho;Koo, Jae Raeyang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.464-469
    • /
    • 2012
  • In the electric power plant, the shaft vibration is one of the very important point for successful long-term operation, because the high reliability unit needs stable rotor dynamic system. However, in the one combined cycle power plant, the abnormal high level shaft vibration analyzed 1 X on the journal bearing has been several times suddenly tripped of Gas turbine due to the accumulated oil carbide. This paper describes how to countermeasure the abnormal shaft vibration in the journal bearing of Gas turbine exhaust bearing in the field.

  • PDF

The Performance & Operation Analysis of a Plate Type Reformet for 2 kW Class MCFC Stack (2 kW급 MCFC용 평편형 개질기 운전결과)

  • Seo, Hal-Kung;Ahn, Kyo-Sang;Lim, Hee-Chun;Lee, Sang-Deuk
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 2002
  • The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.

Development of Monitoring System for Safety Operation of Crane (크레인 안전 운전을 위한 모니터링 시스템 개발)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1305-1310
    • /
    • 2014
  • In this paper, the new integrated crane monitoring system that complemented the point at issue for existing crane monitoring system is implemented. The Implementing monitoring system based on wireless communication system, consist of a measuring system of total load currents of main circuit breaker, a temperature and vibration measuring system with temperature sensors and vibration sensors for monitoring an oil and bearing of a main decelerator, a temperature measuring system with temperature sensors of a main motor bearing, and sensors for fire monitoring of an entire electrical space. The measured data from these sensors transmit main controller which is located in external location. Then the Integrating monitoring system is implemented and is performed the performance test to performing diagnosis of motors of a crane.

A Study on Development of Virtual MCR Collaboration Training System (가상 MCR 협동 훈련 시스템(Virtual MCR Collaboration training System)에 관한 연구)

  • Yoo Hyeon Ju;Lee Yong-Gwan;Lee Myeong-Su;Hong Jin-Hyeok;Choe Jin-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.124-127
    • /
    • 2001
  • 가상현실 기술을 이용한 컴퓨터 지원 교육훈련 시스템 (VR-CATS: Virtual Reality based Computer Assisted Training System) 개발에 대한 연구를 전력연구원에서는 계속 수행해 왔다. 본 논문에서는 New VR-CATS (울진 3호기 참조)중 가상현실에서의 공동 협동 훈련 시스템(Virtual Reality Collaboration Training System)의 설계에 관하여 서술한다. 공동작업은 발전소 MCR(Main Control Room)을 3D 데이터 모델링 후 가상현실화하고 MCR 내부를 Navigation 할 수 있도록 가상패널(Virtual Panel)을 개발 및 에에 대한 엔지니어링 데이터베이스환경을 작성하여 추후 정확하고 신속한 계기 정보를 얻을 수 있도록 하며 훈련생들이 시뮬레이터실로 가지 않고 MCR에서 발전소를 운전하는 것과 같은 효과를 강의실에서 얻을 수 있다. 또한 설계기준사고 중의 하나인 LOCA 사고 복구 훈련 시나리오를 통하여 실제와 동일한 복구 훈련을 하므로서 효율적이며 현장감있는 교육훈련 수행을 가능케 한다.

  • PDF

Source Identification and Coutermeasure Application for Outdoor Noise of Diesel Engine Generator (디젤 엔진 발전기의 실외 소음원 규명 및 대책수립 사례)

  • 김원진;전민규;김중기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.50-54
    • /
    • 1996
  • 최근들어 전력수요와 상시 전력공급이 요구되는 시설이 증가함에 따라 독립적으로 전력을 공급할 수 있는 상용 또는 비상용발전기가 많이 이용되고 있는 추세이다. 이러한 소형 발전시스템에는 디젤엔진이나 터빈 엔진에 발전기를 연결하여 전력을 공급하는 코젠 시스템(co-generation system)이 주로 이용된다[1]. 일반적으로 코젠시스템은 운전중에 매우 높은 수준의 소음이 발생되므로 건물 주변이나 사람의 왕래가 잦은 곳에 설치되는 경우에 필히 소음저감을 위한 대책이 필요하게 된다[2,3]. 본 사례는 대형놀이시설의 전력공급용으로 설치된 옥내(발전실내)의 상용/비상용 발전기(3600 KW 디젤엔진 2대)에서 발생한 상당량의 소음이 놀이시설주변까지 전달되어, 소음원 및 그 전달경로를 규명하고 대책을 수립한 내용이다. 놀이시설의 개장을 앞두고 소음문제가 발생되었기 때문에 신속하고 현실적인 해결책의 적용이 요구되었으므로 발전기 및 발전실 주변의 소음레벨 및 주파수특성의 분석을 통하여 주소음원을 규명하는 방법을 택했다. 분석결과로부터 주 소음원은 엔진 배기구에서 발생되는 저주파수 특성을 갖는 소음으로 규명되었고, 그 주파수특성에 적합한 흡음 및 반사특성을 동시에 갖는 조합형 2차 소음기를 추가로 설치하여 발전실 주변소음레벨을 크게 저감할 수 있었다.

  • PDF

CFD Study of the Vacuum-Pump Type Subsonic/Sonic Ejector Flows (진공 펌프형 아음속/음속 이젝터 유동에 관한 수치 해석적 연구)

  • 김희동;권오식;최보규
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.26-35
    • /
    • 2000
  • This paper depicts the computational results for the axisymmetric subsonic/sonic ejector systems with a second throat. The numerical simulations are based on a fully implicit finite volume scheme of the compressible Reynolds-Averaged Navier-Stokes equations in a domain that extends from the stagnation chamber to the ejector diffuser exit. In order to obtain practical design factors for the subsonic/sonic ejector systems which are applicable to industrial vacuum pumps, the ejector throat area, the mixing section configuration, and the ejector throat length are changed in computations. For the subsonic/sonic ejector systems operating in the range of low operation pressure ratios, the effects of the design factors on the vacuum performance of the secondary chamber are discussed.

  • PDF