• 제목/요약/키워드: 우오수분리벽

검색결과 4건 처리시간 0.019초

합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과 (Effect of separation walls on reduction of suspended solids loading in a combined sewer system)

  • 권충진;임봉수
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.

우오수분리벽을 이용한 합류식 하수관거의 오염물질 제어효과 (Pollutant Control using the Separation Wall between Stormwater and Sewage in a Combined Sewer System)

  • 이광춘;최봉철;임봉수
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.461-469
    • /
    • 2004
  • This research is to determine the stormwater effects on sewer concentrations by measuring and comparing the flow and pollutant concentrations during dry and rainy periods in the existing BOX type combined sewer pipes. The monitoring was carried out in two sites, which are the Daesachen outfall having PE separation wall in BOX type combined sewer pipes and the Yongunchen outfall not having seperatioin wall. The average flow-weighted BOD concentraion in Yongunchen outfall is 2-fold lower than in Daesachen outfall because of the dilution effect from ravine water. However, the pollutant mass loading is 16 fold higher in Yongunchen outfall than in Daesachen outfall because of more flows. According to the research, the separation wall controls 52% pollutant mass during a storm period (11.5 mm/hr rainfall intensity). Therefore, the Yongunchen combined sewer system (CSS) need separation wall to control and to prevent more pollutant input in stream. In Daesachen area, the maximum sewer flow rate during a storm period measured about 10 fold bigger than average sewer flow during dry periods. Also the concentrations between rainy and dry periods increase approximately 33 fold for BOD and 120 fold for SS. In Yongunchen area, it increases about 9 fold for the maximum flow rate, 18 fold for BOD and 22 fold for SS during a storm. Therefore, the research is concluded that the separation wall between stromwater (or ravine water) and sewage can decrease the dilution effect in CSS and control the pollutant loading.

우오수분리벽을 이용한 합류식 하수관거와 분류식 우수관거의 월류수 제어효과 비교 (Comparison of Pollutant Control in Combined Sewer Overflows and Separated Sewer Overflows using the Separation Wall)

  • 임봉수;김도영;이광춘
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.458-466
    • /
    • 2007
  • This study is to evaluate control effects of separation wall by surveying water quality and sewer overflows during dry and wet periods in combined sewer and separated sewer systems. Ravine water from the combined Seokgyo outfall with the separation wall was separated about four times larger than sewage flow during dry periods. The water quality of the combined Seokgyo outfall with separation wall during dry periods is flow weighed average BOD 61 mg/L, the combined Cheonseokgyo outfall without the separation wall is average BOD 71 mg/L, and the separated Pyeongsong center outfall is average BOD 41 mg/L. The BOD concentration in separated outfall form about 57% of the combined outfall, and this means the separated outfall (i.e. storm sewer) is polluted by inflow of sewage. The overflow load of the separated outfall is ten times higher than the combined outfall and its overflow load per rainfall is three times than combined outfall during the wet periods. Therefore, the control plan of overflow load is required in storm sewer. The control effects of the overflow load increased 79% by setting the separation wall in the combined sewer, and showed 27% increase without the separation wall in separated sewer, but forecasted over 80% increase of effects if the separation wall was set.

안양천 유역의 물순환 건전화를 위한 통합관리방안(II): 예비 타당성 계획 (Integrated Approach for Rehabilitating the Hydrologic Cycle in the Anyangcheon Watershed(II): Prefeasibility Study)

  • 이길성;정은성;김영오
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.497-501
    • /
    • 2005
  • 근래 들어 도시화로 인한 물순환 파괴를 근본적으로 연구하고 이를 정상화하기 위한 체계적이고 통합적인 유역관리 기술이 요구되고 있다. 유역통합관리의 이론을 실제로 적용한 계획을 세우기 위해서는 Heathcote(1998)가 제안한 다음과 같은 단계별 절차를 수행하는 것이 바람직하다. 단계별 절차는 (1) 대상유역에 대한 정보수집, (2) 문제점 도출, (3) 분명한 목적 수립, (4) 대안의 구성, (5) 대안의 검토, (6) 대안의 효과분석, (7) 최종계획 수립으로 이루어져 있으며 본 연구에서는 3단계의 과정에 해당된다. Heathcote(1998)는 대안의 선정과 평가를 위한 방법으로 단순평가방법(simple assessment method)과 세부평가방법(detailed assessment method)으로 구분하였는데 본 연구에서 수행한 내용은 단순평가방법에 해당된다. 본 연구는 안양천 유역에서 물순환 건전화의 핵심을 건천화 방지로 판단하고 이를 위한 대안을 크게 지표수, 지하수, 대체수자원 분야로 구분하여 제시하였다. 지표수 분야의 경우 구조적인 대안으로 소규모 저수지의 개발, 타유역에서의 도수, 보를 이용한 수량 확보, 우오수분리벽을 이용한 상류유출수의 확보, 저협수로 형성, 하천바닥에 차집관로 매설 방지 및 차집관로 유지관리 등이 있으며 비구조적인 대안으로는 기존 저수지의 유지용수 공급을 위한 운영, 유수지의 다목적 활용, 하천수 직접취수 제한 등이 있다. 지하수 분야의 대안으로는 지하철 용출수의 재이용, 지하수의 과다이용 제한, 침투증진시설의 설치 등이 있으며 대체수자원 분야의 대안으로는 하수처리수를 고도처리하여 유지용수로 재이용하는 것, 중소규모 하수처리장의 상류 설치, 대규모 사업장의 폐수를 고도처리하여 활용하는 것, 상수도의 이용 등이 있다. 이러한 여러 가지 대안들은 Walesh(1989)가 제안한 절차에 따라 기술가능성(technical feasibility), 경제성(economical efficiency), 환경성(environmental feasibility) 등을 정성적으로(qualitatively) 파악하여 실현가능한 대안을 선정하였다. 이렇게 선정된 대안들은 중유역별로 검토하여 효과가 있을 것으로 판단되는 대안들을 제시하는 예비타당성(Prefeasibility) 계획을 수립하였다. 이렇게 제시된 계획은 향후 과학적인 분석(세부평가방법)을 통해 대안을 평가하고 구체적인 타당성(feasibility) 계획을 수립하는데 토대가 될 것이다.

  • PDF