• Title/Summary/Keyword: 우신건축

Search Result 4, Processing Time 0.023 seconds

회원작품

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.3 s.121
    • /
    • pp.35-49
    • /
    • 1979
  • PDF

환경친화적 생태주거 건물의 설계

  • 한현주
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.6
    • /
    • pp.37-42
    • /
    • 2000
  • 환경친화적 생태주거 건물에 대하여 개념적으로 살펴보고 아울러 이의 구현을 위한 여러 방법론 등에 대하여 기존의 건축 기법과 시공예를 분석하여 이에 대한 이해를 제고한다.

  • PDF

A Proposal about the Vertical Fire Suppression Methods of High-rise Buildings (초고층 수직화재의 진압방법에 대한 제안)

  • Min, Se-Hong;Bae, Yeon-Jun;Nam, Yu-Hyeon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.163-166
    • /
    • 2012
  • 최근 국내 대도시를 중심으로 초고층건축물이 계획 건립되고 있으며, 그에 따라 국내 외적으로 초고층건축물 화재가 빈번하게 발생하고 있으나, 현재 국내 소방기술은 그에 대한 어떤 확실한 대안도 갖고 있지 못하다. 2010년 발생한 부산 해운대 우신골든스위트 화재사례를 통해 고층건물 화재진압의 부진했던 주된 원인과 문제점이 분석되면서, 최근 국내 고층건축물의 화재를 대비한 관련법(건축법, 소방법 등)들이 제정되고 있다. 그러나 아직도 고층건축물에서의 화재진압방법, 인명구조 및 소방진압장비의 연구 개발의 성과가 부족하다. 본 연구에서는 초고층건축물의 외장재를 통한 수직화재 확산방지를 위한 보다 효과적인 진압방법과 인명구조방법을 제안하고자 한다.

  • PDF

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.