• Title/Summary/Keyword: 우물관정

Search Result 17, Processing Time 0.025 seconds

Research of geothermal analysis and experimental test for Standing Column Well type system (우물관정(SCW: Standing Column Well)형 냉난방 시스템의 지중열 해석과 실증 실험에 관한 연구)

  • Kwon, Iksang;Hong, Gibae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.173-173
    • /
    • 2010
  • This thesis identified basic design elements (Sustainable Yield, Temperature of Groundwater, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

Research for geothermal analysis on design of Standing Column Well type system (우물관정(SCW: Standing Column Well)형 지열 냉난방 시스템 설계를 위한 지중열 해석에 관한 연구)

  • Kwon, Ik-Sang;Rhee, Kwon-Joong;Kim, Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.576-580
    • /
    • 2009
  • This thesis identified basic design elements(Sustained Yield, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

A Case Study on the Installation and Operation of the Standing Column Well Method (우물관정형(SCW공법) 지열히트펌프 시스템의 설치 및 운영사례)

  • Na, Sang-Min;Park, Si-Sam;Park, Jong-Hun;Rhee, Keon-Joong;Kim, Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.592-595
    • /
    • 2009
  • In recent years, geothermal heat pump (GHP) systems have become increasingly popular for heating and cooling in buildings. The Standing Column Well (SCW) method is one of the most efficient GHP system. Because it use groundwater for heat transfer material. In SCW systems, water is re-circulated between the well and the building (heat pump). It is only a short time since this method has been applied in domestic. So we have to refer to the developed countries' guides and manuals of SCW. In this paper, several design and construction points of SCW method are filed. We used real operation data of SCW system at Chong-Ju Univ. site for economical efficiency analysis. As a result, the payback period of Chong-Ju Univ. site is calculated at 7.23 years.

  • PDF

Application of the Artificial Recharge to Reduce the Ground-water Drawdown of the River Bank Filtration (강변여과수 취수시 과도한 지하수 하강을 저감시키기 위한 인공함양의 활용 방안)

  • Lee, Dong Kee;Park, Jae Hyeoun;Park, Chang Kun;Kim, Sang Jun;Nam, DoHyeoun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.236-240
    • /
    • 2004
  • 강변여과수의 과도한 취수는 제내지 지하수위 하강을 발생하게 되며 이로 인해서 제내지 농경지의 토양 건조도가 증가되어 과도한 관계용수의 보충이 필요할 뿐말 아니라 지하수위 하강으로 인한 기존 관정사용이 어려워져 더 깊은 새로운 관정을 개발해야만 한다.. 이러한 기하수위 하강을 저감시키기 위한 방안으로 제내 지측에 인공함양우물을 설치하는 방법 있다. 창원시 강변여과 시설에 적용한 결과 인공함양우물의 최적 위치는 취수정으로부터 세내지 측으로 200m 지점에 위치하며, 함양량을 취수량의 $5\%$를 유지하는 것이 지하수위를 저감하기위한 효과적인 조건으로 판단되었다.

  • PDF

Effects of Well Parameters Analysis Techniques on Evaluation of Well Efficiency in Step-Drawdown Test (단계양수시험 해석시 우물상수 산정 방법이 우물효율에 미치는 영향)

  • Chung, Sang-Yong;Kim, Byung-Woo;Kim, Gyoo-Bum;Kweon, Hae-Woo
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 2009
  • Step-drawdown tests were conducted at four pumping Wells, two in porous media and two in fractured rocks, respectively. In general, P = 2.0 suggested by Jacob (1947) is applied to porous media and fractured rocks in terms of drawdowns of step-drawdown test. In an attempt to review problems of linear model (Jacob's graphic method) in interpreting the step-draw down test, the outcomes of well parameters (aquifer loss coefficient (B), well loss coefficient (C) and well loss exponent (P)) calculated from linear and nonlinear model (Labadie and Helweg's least-squares method) were compared and analyzed. The values of C and P calculated from linear and nonlinear models differed according to permeability of aquifer and the conditions of pumping well. The value C obtained from nonlinear models in porous media and fractured rocks is about $10^0{\sim}10^{-2}$ and $10^{-3}{\sim}10^{-6}$ times lower than in their linear models, respectively. The value P of porous media obtained from nonlinear model ranged from 2.123 to 2.775, while it ranged from 3.459 to 5.635 for fractured rocks. In case of nonlinear model, well loss highly depends on the value P. At this time, well efficiencies calculated from linear and nonlinear models were $1.56{\sim}14.89%$ for porous media and $8.73{\sim}24.71%$ for fractured rocks, showing a significant error according to chosen models. In nonlinear model, it was found that the regression analysis using the least squares method was very useful to interpret step-drawdown test in all aquifer.

Restriction of groundwater drawdown levels in one representative drought-prone zone (상습가뭄지역 지하수위 한계치 설정 연구)

  • Lee, Byung Sun;Myoung, Wooho;Lee, Gyu Sang;Song, Sung-Ho;Ha, Kyoochul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.31-31
    • /
    • 2020
  • 가뭄 발생 시 국내 농어촌 지자체 대부분은 추가 수원공 확보를 위한 긴급 대책으로 신규 관정을 개발하거나, 저수지와 하천을 준설하여 가뭄 수요에 대응하는 편이다. 이러한 방법은 즉시 대응에는 효과가 있지만, 고가의 비용이 소요되고, 무엇보다도 국지적으로 가뭄이 빈번하게 발생하는 지역에는 적용에 한계가 있다. 이러한 한계를 극복하기 위하여, 최근 기설 관정을 연계 이용하여 지하수 공급 극대화를 도모하는 기술이 제안되었다. 그런데 기설 관정 연계 이용 시 가장 중요한 사항은 모든 관정에서 최대 양수량을 유지하며 지하수를 공급할 수 있도록 관리해야 하는 점이며, 특히 암반관정의 과잉양수로 인한 간섭현상으로 충적관정이 고갈되어 공급가능한 지하수 수량이 오히려 감소되는 것을 사전에 방지하여야 한다. 이 연구에서는 가뭄 발생 시 암반관정(양수정)에서 최대로 양수했을 때에도 주변 충적관정의 양수능이 유지되는 최소 지하수위를 「지하수위 저하 한계치」로 지정하여 관정 연계 이용의 최적화를 도모하였다. 지하수위 저하 한계치 산정을 위하여, Theis의 자유면 대수층 정상류 우물수리 방정식과 지하수영향반겅 설정에 관한 경험식(Schultz, Weber, Kozeny 및 Jacob 경험식)을 이용하였다. 그런데 지정된 지하수위 저하 한계치는 충적관정의 지하수위이므로, 암반관측공만 소재하는 지역에 대해서는 충적층 지하수위 변동과 암반층 지하수위 변동 간의 상관분석을 통해 암반 관측공의 지하수위 저하 한계치를 추정하였다. 이후, 양수시험 자료(양수정과 주변 관측공의 수위변동 자료)를 이용하여 지하수 대수층의 이방성을 확인하였고, 이를 통해 암반관정의 양수에 따른 간섭을 크게 받는 충적관정과 그렇치 않은 충적관정을 구분하여 이방성에 따른 지하수위 저하 한계치를 수정하고, 상습가뭄 발생지역의 암반관정과 충적관정의 최적 지하수 양수를 도모하였다.

  • PDF

Application of Regression Tree Model for the Estimation of Groundwater Use at the Agricultural (Dry-field Farming and Rice Farming) Purpose Wells (농업용(전작 및 답작용) 지하수 이용량 추정을 위한 회귀나무 모형의 적용)

  • Kim, yoo-Bum;Hwang, Chan-Ik
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.417-425
    • /
    • 2019
  • Agricultural groundwater use accounts for 51.8% of total groundwater use, so accurate estimation of groundwater use is important for efficient groundwater management. The purpose of this study is to develop a method for estimating the groundwater use of agricultural (rice farming and dry-field farming) wells using regression tree model based on the measured data of 370 wells. Three input variables of the model were evaluated as being significant: well depth, pipe diameter, and pump capacity, and the importance of each variable was 75% for well depth, 17% for pipe diameter, and 8% for pumping capacity. The daily usage of agricultural (rice farming and dry-field farming) wells by the regression tree model was estimated to be very similar to the actual usage, compared to the previous estimation method proposed by the Ministry of Construction and Transportation. In the future, it is expected that the reliability of the usage statistics will be improved if additional observed data is secured and this classification method is modified.

Application of the Artificial Recharge to Reduce the Ground-water Drawdown of the Riverbank Filtration (강변여과 취수시 과도한 지하수 하강을 저감시키기 위한 인공함양의 활용방안 연구)

  • Lee Dong-Kee;Park Jae-Hyeoun;Park Chang-Kun;Yang Jung-Suk;Nam Do-Hyun;Kim Dae-kun;Jeong Gyo-cheol;Choi Yong-sun;Boo Sung-an
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.391-400
    • /
    • 2004
  • Excess pumping on the river bank filtration well causes the over drawdown in the protected area of bank, which may make many problems such as soil water contents, Pumping head in the irrigated land, and it needs more irrigation and development of the deeper irrigating well. In this study the installation of the artificial recharging well was suggested to reduce the excess draw down in the protected land. Artificial recharging wells were applied at the bank filtration site of Changwon city by using Visual-MODFLDW. The optimized conditions are calculated that the recharging well is located about loom apart from the pumping well, and the recharging rate is $5\%$ of the pumping yield.