• Title/Summary/Keyword: 용존오존부상

Search Result 5, Processing Time 0.028 seconds

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System (DOF 공정에 의한 정수처리 효과)

  • Lee, Byoung-Ho;Song, Won-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.743-750
    • /
    • 2008
  • In water treatment plant the Dissolved Ozone Flotation(DOF) System may be employed because this system has various abilities, such that it can remove SS using microbubbles, and it can exert strong oxidation power in removing taste and odor, color, and microbial agents. In order to investigate effectiveness of the DOF system in water treatment, removal characteristics of various water quality parameters were observed depending on the different levels of ozone concentrations. Removal efficiencies of water quality parameters in DOF system were compared with those in DAF(Dissolved Air Flotation) system and in CGS(Conventional Gravity Settling) system. Optimum ozone dose obtained in the pilot experiments was 2.7 mg/L. With increasing ozone dose higher than 2.7 mg/L, removal rates of turbidity, KMnO$_4$ consumption, UV$_{254}$ absorbance, and TOC were reversely lowered. High concentration of ozone dissociate organic matter in water, so that increasing dissolved organic level in effluent. Removal rates of water quality parameters at optimum ozone dose were obtained, such that removal rates of turbidity, KMnO$_4$ consumption, TOC, and UV$_{254}$ asorbance were 88.9%, 62.9%, 47%, and 77.3% respectively. Removal rate of THMFP was 51.6%. For all the parameters listed above, the DOF system was more effective than the DAF system or the CGS system. It is found that the DOF system may be used in advanced water treatment not only because the DOF system is more efficient in removing water quality parameters than the existing systems, but because the DOF system is also required smaller area than the CGS system for the treatment plant.

Reclamation of Effluent Textile Wastewater Using Micro/nano Bubbles-Dissolved Ozone Flotation Process (초미세기포-용존오존부상(DOF)공정을 이용한 염색폐수 처리수의 재이용)

  • Jung, Byung-Gil;Lee, Ki-Hyung;Jung, Jin-Hee;Jang, Seong-Ho;Cho, Do-Hyun;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.291-299
    • /
    • 2011
  • The main objectives of this research are to investigate characteristics of ozone solubility due to low solubility of conventional bubbles-ozone generators, evaluate the treatment characteristics of reclaiming textile wastewater for industrial water by means of micro/nano bubbles-dissolved ozone flotation(MNB-DOF) process. The textile wastewater used in this research was obtained from final effluent of the textile wastewater in B city. There is a 400L reactor which consists of a micro-nano bubble system and a ozone generator for experiments. As a result of generating micro-nano bubbles (below $0.5{\mu}m$) by using of MNB-DOF process, it improved ozone solubility due to higher ozone transfer rates. Consequently, the shorter ozonation time clearly indicates the lower power costs. The reported results clearly indicated that MNB-DOF process can be effectively and inexpensively. Results of the experiments through MNB-DOF process in this study satisfy all reclaiming standards as industrial water: pH 6.5~8.5, SS 10 mg/L or below, $BOD_5$) 6 mg/L or below, turbidity 10 NTU or below, Coliforms 1,000/100 mL or below. Therefore there is a possibility of the reclaiming of the textile wastewater as industrial water.

Saline Water Treatment by Underwater Plasma

  • Yu, Seung-Min;Yu, Seung-Yeol;Park, Jun-Seok;Hong, Eun-Jeong;Hong, Yong-Cheol;Lee, Sang-Ju;Kim, Ye-Jin;No, Tae-Hyeop;Lee, Bong-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.19-19
    • /
    • 2011
  • 수중방전은 다양한 라디칼을 직접 물 속에서 발생시키기 때문에 수처리 공정에 다양한 응용이 가능하다. 특히, 최근에 선박평형수 등의 살균이 국제적인 이슈가 되고 있고, 2017년까지는 모든 선박에 살균을 위한 수처리 설비가 의무화된다. 본 연구에서는 염분이 있는 수체에서의 방전공정을 연구하고 이를 수처리공정에 적용할 수 있는 방법에 대해 연구하였다. 해수의 경우 전도도가 53mS로 자유로운 전하의 이동이 가능하기 때문에 일반적인 민물방전의 전원과 전극 등으로는 방전을 할 수 없다. 이에 세라믹과 금속의 이중구조로 되어 있는 모세관전극을 개발하여 전도성이 있는 수체에서의 방전을 이루었다. 전원장치로는 60 Hz, 380 V를 1차측에 인가하여 2차측에서 약 3 kV, 10 kW의 파워가 발생하는 12위상차 교류전원장치를 개발하여 사용하였다. 모세관 내부에 전압이 인가되면 전류가 발생하여 joule heating에 의하여 모세관 내부에 기포가 형성된다. 이 때, 전류의 단락이 이루어지면서 고전압쪽에 전하가 축적되며 기포내부의 E-field가 상승한다. 이후 기포 내에서 방전이 개시되며 각종 라디칼을 생성한다. 방전에 의해 생성되는 산화제로는 오존, OH라디칼, 과산화수소 등이 있으며, 해수에서는 Cl-의 결합에 의하여 Cl2 가스가 발생한다. 약 30,000 J/L의 체적에너지에 대하여 생성되는 총염소의 농도는 2.5 mg/L이다. 수중방전의 적용대상으로 선박평형수, 멤브레인과의 결합, 용존기포부상법을 선정하여 적용가능성을 연구하였다. 먼저 선박평형수 살균처리를 위해 해수의 처리유량을 20 lpm으로 유지하고 대장균, 바실러스, 조류(테트라셀미스) 등을 투입하여 전극 12개가 삽입된 12위상차 플라즈마 반응기를 통과시켰더니, 약 30,000 J/L의 체적에너지에 대하여 1일 후의 살균력이 각각 99.99, 99.99, 99.9%의 살균력을 나타내었다. 이는 국제해사기구에서 권장하는 살균수준인 99.9%를 초과하는 수치이다. 플라즈마를 이용한 해수살균공정의 안정적 운전을 위해 후단에 UF멤브레인을 추가하여 잔류생존 미생물을 제거할 수 있다. 이를 위해 플라즈마가 후단의 멤브레인 운전에 미치는 영향을 평가하였다. 카올린과 탄산칼슘을 오염원으로 각각 투입하여 멤브레인으로 처리를 하였을 때, 방전 직후 멤브레인에 걸리는 막간압력차가 약 30% 감소하였는데, 이는 막에 형성된 파울링이 방전에 의해 제거된 것으로 평가할 수 있다. 수중방전은 다양한 산화제를 생성함과 동시에 미세기포를 발생시키는데 이는 수중유기물의 부상분리에 적용될 수 있다. 방전모세관전극의 내부직경을 1 mm로 유지하고, 60 Hz, 교류전원으로 방전한 결과 평균입경 44 um의 기포를 발생시켰고, 이는 일반적으로 용존공기부상법에 사용되는 기포의 크기와 일치한다.

  • PDF

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.