The Effect of Blast Cleaning for Steel Bridge Painting on Fatigue Behavior of Out-of-Plane Gusset Welded Joints (강교 도장용 블라스트 처리가 면외거셋 용접이음의 피로거동에 미치는 영향)

  • Kim, In Tae;Le, Van Phuoc Nhan;Kim, Kwang Jin;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.583-590
    • /
    • 2008
  • Blasting has been applied in newly-built steel structures for cleaning forged surfaces and increasing the adhesive property of applied painting systems. However, the effect of the blast cleaning on fatigue behavior of welded joints is not clear. In this paper, fatigue tests were carried out on out-of-plane gusset welded joints and the effect of the blast cleaning on the fatigue behavior was studied. The curvature radius at the weld toe of the surface-treated specimens by using the blast method is larger than that of as-welded specimens. By the blast cleaning compressive residual stresses were induced into weld toes. The experimental results showed that the fatigue life of surface-treated specimens is longer than that of as-welded specimens, even though the fatigue life of surface-treated specimens and that of as-welded specimens are not clearly different in the high stress range. About a 160% increase in fatigue limit could be realized by using blast cleaning.

A Study on the Fatigue Characteristics in Butt-Welded Joints with Incomplete Penetration (용입부족을 가진 횡방향 맞대기 용접부의 피로특성에 관한 연구)

  • Chang, Dong Il;Kyung, Kab Soo;Hong, Sung Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.497-508
    • /
    • 1998
  • The objective of this study is to examine fatigue behavior of as-welded butt-welded joints with incomplete penetration from fatigue tests. The test results are the following. In static tests, tensile strength and yield strength of butt-welded joints are constant regardless of incomplete penetration. And in fatigue tests, fatigue strength of fully penetrated butt-welded joints satisfies fatigue limits, prescribed in Korean Specifications and JSSC, respectively. The results show that as the magnitude of incomplete penetration increases, fatigue strength decreases. In fractured surfaces, full and incomplete penetration specimen show different shapes, it is because that stress concentration factor vary with structural geometry in bead toe and root tip, and certify in FEM analysis. This study suggests that defects such as incomplete penetration from welding must be avoided in order to attain the sufficient life of steel structures.

  • PDF

Modeling Scheme for Weld-Jointed Parts for Precise Structural Analysis of Large-Scale Structures (대형구조물의 구조해석 정밀도 향상을 위한 용접부 모델링 기법)

  • Jin, Dawei;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1195-1203
    • /
    • 2012
  • Welding is a well-developed, widely used process for permanently joining metal components. However, the mechanical reliability of welded parts still offers room for improvement. A weld region consists of a fusion zone, a partially melted zone, and a heat-affected zone, and each zone has different material properties. In addition, the geometrical shape of a weld bead or fillet influences the mechanical reliability. A precise structural analysis must consider how a local welded region influences the mechanical behavior of the entire structure. This study focuses on an effective modeling scheme for the weld region. It relies on experimental and numerical methods to determine the proper correlation based on experimental results and to propose a modeling scheme for welded parts.

A Study on the Effect of Heat Input on the Microstructure and Toughness of Weldments Made by Domestic Flux Cored Wires. (국산 플럭스 코어드 와이어 용접에서 입열량이 용접부의 미세조직과 인성에 미치는 영향)

  • 고진현;국정한
    • Journal of Welding and Joining
    • /
    • v.11 no.4
    • /
    • pp.57-69
    • /
    • 1993
  • In the present study, the microstructure and Charpy V notch toughness of multipass $CO_2$ FCA weldment in three different heat inputs(1-3KJ/mm)were investigated. The weldments using two different domestic FCAW wires(AWS E71T-1 and E71T-5 equivalent) in C-Mn steel were chemically analysed. The following conclusions can be inferred. 1. T-1 wire Showed a stable arc transfer, less spatter and harsh, a better bead spreading and easy slag removal, whereas T-5 wire suffered from the arc stability, which tended to increase spatter and produce a more convex bead. 2.The microsturctures of the top beads of the weldments in three different heat inputs consisted of coarse-grained boundary ferrite and Widmanstatten ferrite side plate with increasing heat inputs. The modest fraction of acicular ferrite in the two wire weldments was observed in the 2KJ/mm heat input. 3.The fine-grained reheated zones of both welds consisted of a duplex microstructure of polygonal ferrite and second phases. 4. The basic flux weldment of T-5wires showed a higher Charpy impact property than that of T-1 wires because of a higher fraction of acicular ferrite in the weld microstructure.

  • PDF

The Experimental Study of Flux Improvement of Wet Underwater Arc Welding Electrode (습식 수중 용접봉의 피복제 개발에 관한 기초연구)

  • Kim, Min-Nam;Kang, Jung-Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.28-36
    • /
    • 1999
  • Wet underwater arc welding process is investigated by using experimentally developed flux coated underwater arc welding electrode and SS400 steel plate of 12mm thickness as base metal. Three kinds of different flux covered wet arc welding electrode of 4mm diameter(BK-01, BK-02, BK-03) are individually developed, and one of the improved underwater welding electrode (BK-03) may be put to practical use for underwater wet arc welding process. The results obtained from this experimental study are as follows : 1. Arc stability of developed underwater wet welding electrode is better than that of the domestic covered arc welding electrode. 2. Workability of welding electrode, remove ability of slag and bead appearances using improved underwater wet welding electrode are remarkably better than that of others. 3. Heat affected zone of test specimen welded in the underwater gets to become a lot smaller than that of test specimen welded in the air, and the maximum hardness of heat affect zone of developed underwater wet welding electrode is lower to that of domestic arc welding electrode.

  • PDF

The characteristics of bead welding on steel with process parameter during the laser-arc hybrid welding(II) - Effect of heat input parameters - (강의 레이저-아크 하이브리드 용접시 공정변수에 따른 비드용접특성 (II) - 용접 입열 변수의 영향 -)

  • Kim, Jond-Do;Myung, Gi-Hoon;Park, In-Duck
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.91-96
    • /
    • 2015
  • The laser-arc hybrid welding of SS400 steel was carried out with the use of disk laser equipment of 6.6kW maximum power and MAG equipment of pulse mode. Parameter regarding heat input is one of the most important factors that directly affect penetration characteristics and welding defect. Therefore in this study, the effects of laser power, welding speed and current, voltage and pulse correction were investigated. As experiment result, it was found that the lower heat input, the more likely humping bead is formed at the back, and such humping bead could be suppressed by increasing laser power and arc current or decreasing welding speed, thus increasing heat input. Also deep penetration could be achieved by reducing arc voltage or pulse correction parameter in the same welding condition.

An Experimental Study on the Arc Stability Improvement of Underwater Wet Welding with Flux Ingredients (피복성분에 의한 수중용접봉의 아크 안정성 개선에 관한 실험연구)

  • 김복인;노창석;정교헌;김민남
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.73-79
    • /
    • 2001
  • Underwater wet bead-on-plate welds were experimentally performed on 11mm thick SS400 steel plate as base metal by using six different types of flux coated electrodes of 3.2mm diameter. Two kinds of different flux coated wet arc electrodes (UW-1, UW-2) were individually designed flux materials, three kinds of the electrodes (E4301, E4311, E4313) were terrestrial electrodes and the another one (TN20) was an imported underwater wet welding electrode. As results, the individually designed flux coated underwater electrode, UW-2 and TN20 had a good starting and the excellent arc stability compared with other electrodes. No significant difference of bead appearance could be detected, but the slag detachability of TN20 electrodes was relatively undesirable. By rapid cooling rate, the hardness value and the portion of martensite of HAZ were increased, but it was considerably maintain stable for TN20 and UW-2 electrodes. The individually designed flux coated electrode, UW-2 could be used in practice for underwater bead welds.

  • PDF

A Study on In-process Measurement in Laser Welding of Primer-coated Steel for Shipbuilding (II) -Defect Detection with Coating Condition and Gap Clearance- (조선용 프라이머 코팅 강판의 레이저용접시 인프로세스 측정에 관한 연구 (II) -코팅조건과 갭간극에 따른 불량검출-)

  • Kim, Jong-Do;Lee, Chang-Je;Lee, Jae-Bum;Hong, Seung-Gab;Park, Hyun-Jun
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.115-115
    • /
    • 2009
  • 아연코팅강판의 레이저 용접시 발생하는 용접결함은 이미 널리 알려진 이슈이다. 그러나 대부분의 연구가 박판을 중심으로 이루어지고 있어서, 후판을 중심으로 한 조선산업에서의 아연코팅 강판의 연구는 매우 미진한 실정이다. 이중 후판 아연코팅강판의 결함검출연구는 그 연구가 거의 전무한 실정으로, 본 연구에서는 후판 아연코팅강판의 레이저 겹치기용접시의 결함검출을 중심으로 실험을 실시하였다. 실험은 Fig. 1에서와 같이 광신호와 음향신호의 RMS를 통하여 raw signal에서 잘 나타나지 않았던 신호의 패턴을 확인함으로써 실제 신호와 비드와를 대응을 가능하게 하였다. 또한 결함 발생시의 RMS값을 건전한 상태와 비교분석하여 실제 결함검출의 가능성도 확인할 수 있었다.

  • PDF

Development of Automated Ultrasonic Testing System for Partial Joint-Weld of Heat Exchanger's Header to Tube in Power Plant (발전소 열교환기 헤더와 튜브의 부분 용입형 용접부 초음파 자동검사시스템 개발)

  • Lee, Jin-Hyuk;Lim, Seong-Jin;Park, Ik-Keun;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • A power plant's heat exchangers work under poor conditions, such as high temperature, high pressure, corrosion, mechanical stress and vibration. Especially, partial joint-weld of heat exchanger's header to stub-tube is the place where incomplete penetration flaws can easily occur. But, it is hard to evaluate the safety of the structure by conventional nondestructive testing techniques. So it is necessary to test integrity of the weld inside and to develop testing technique and equipment that can detect the flaws at the weld point in order to enhance reliability of the test result. In this study, we developed a suitable automated ultrasonic testing system that can inspect the partial joint-weld of header to stub-tube of power plant. Finally, we showed the efficiency of the automated ultrasonic-testing-system from the application.

Adaptive control of the back bead width in gas metal arc welding process (아크용접에서 이면비드 크기의 적응제어)

  • 부광석;조형석;오준호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.289-294
    • /
    • 1988
  • This paper describes tbe design and implementation of the adaptive controller to maintain the glood weld quality in gas metal arc welding process. The weld torch travel speed and the surface temperature are taken, respectively, as an input and an output of the welding control system. Because of the very complex phenomena of the process, the input-output dynamic model was experimentally identified by AIC (Akiake Information Criterion). Based on the model structure, the explicit model reference adaptive controller is simulated in order to regulate the output tempernture to the desired level.

  • PDF