• Title/Summary/Keyword: 용적식 유량계

Search Result 3, Processing Time 0.019 seconds

Study on Flowmeter Proving Errors of a Small Volume Prover (소형 푸루버의 유량계 검증 오차 연구)

  • 백종승;임기원;최용문
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.259-266
    • /
    • 1990
  • Leaks at the piston seal and the by-pass port of a small volume prover have relatively large influence on the proving accuracy in comparison with a conventional ball prover. The pulse interpolator, which is to increase the discrimination, is affected by the characteristic of the flowmeter signal. In this study, a small volume prover of the double cylinder type was designed in order to study the pulse interpolation error as well as the leak error. The basic volume of the prover determined by a water draw method was about 9.68L. Experimental results revealed that interpolation data attained by the repeated piston pass for turbine meters at a fixed flowrate may be treated effectively by applying a statistical method. It was possible to limit the pulse interpolation error less than .+-. 0.02% at the 95% confidence level. However, in the case of the bulk meter, if failed to achieve the required repeatability level because of the pulse characteristics. The basic volume change appeared to be independent of the piston velocity within the .+-. 0.05% of tolerance.

A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System (기름 유량표준장치의 개발 및 측정 불확도에 관한 연구)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.

Variations of Physical Properties Depending on the Height of Reactor in Vertical Composting Process (수직형 퇴비화공정에서 반응조 높이구간별 퇴비화물질의 물성변화에 관한 연구)

  • Kim, Yong Seong;Kim, Byung Tae;Lee, Chang Hae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.4
    • /
    • pp.115-124
    • /
    • 2007
  • The material compressions in the vertical composting reactor affect to the biodegradation rates of the organic wastes. This study investigated the variations of physical properties of the composting materials according to the height of reactor due to affect to the settlement in the vertical composting reactor. The variations of decreased temperature after peak temperature showed the different patterns depending on the reactor heights. The variation width of re-increased temperature after peak temperature was reduced as the mixing operations were increased, and increased as the height of reactor elevated. The moisture content and the variation width of the moisture content were increased higher as the height of the reactor became higher. The variations of the bulk density at each height of vertical reactor showed the same tendency comparing with those of the moisture content. The relationship between bulk density and moisture content had shown the quadratic equation (r2=0.94). The dry solid contents at each reactor height were decreased as the height of reactor were increased. The results of the variation of the physical properties during the composting process were caused by the downward compression of the material into the reactor. Settlement rate in the vertical composting reactor was estimated about 2.184cm/day. To increase the biodegradation efficiency in the vertical reactor, the conditions of air path in the composting material matrix have to be investigated afterwards.

  • PDF