• Title/Summary/Keyword: 용수 재이용

Search Result 229, Processing Time 0.035 seconds

An Assessment on Efficiency of MBAS Removal in Urban Stream Maintenance Water by Using Sand Filtration (모래여과를 이용한 도시하천유지용수의 MBAS 제거 효율 평가)

  • Kim, hong bae;Ahn, kyung soo
    • Journal of Wetlands Research
    • /
    • v.8 no.2
    • /
    • pp.45-51
    • /
    • 2006
  • Biological enhanced treatment and send filtration are established being operated to remove nutrients and MBAS(Methylene Blue Activate Substance) in the most of Waste Water Treatment Plant(WWTP) in Korea. However, untreated synthetic detergents and nutrients which directly run into the water system present an unpleasant view because of the foam, taste and odor generating filamentous periphytic algae and interrupting self-purification in the stream. Therefore, this research was enforced to know the MBAS removal efficiency of the sand filtration about G WWTP which reuses effluent as urban stream management water. As a result, the maximum removal efficiency using sand filtration was 63% after 24 hours and particularly 30% after 2 or 4 hours which turned out to be not that effective. In conclusion, It is recognized that other methods of MBAS removal and a research will be needed which reuse effluent as urban stream management water from now on. Because the MBAS removal with sand filtration is insufficient with economical efficiency from the fact that it needs long hours for a sand filtration treatment and the removal efficiency was almost below the expectation.

  • PDF

Application of Microfiltration and Reverse Osmosis System to Sewage Reuse for Industrial Water (하수를 공업용수로 재이용하기 위한 정밀여과 및 역삼투 시스템 적용에 관한 연구)

  • 강신경;이해군;김지원
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.151-157
    • /
    • 2002
  • This research was to demonstrate the Possibility of sewage reuse for industrial purpose with use of membrane system. A bench scale test with microfiltration and reverse osmosis showed that microfiltration in the sewage treatment was not able to remove the soluble salts but 70% suspended solids (SS), suggesting that the treated water could be used as direct cooling water. In addition, the reverse osmosis removed not only soluble salts but also 95% SS, proposing that reverse osmosis-treated water could be used as both indirect cooling water and rinsing water. For a 100 ton/day pilot plant, 20 and 12 elements of microfiltration and reverse osmosis were required, respectively.

Evaluation for Drought Vulnerability for national drought management (선제적 가뭄 대응을 위한 전국 가뭄취약성 평가)

  • Jang, Wonjae;Kim, Sinae;Jo, Dongho;Park, Jinwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.16-16
    • /
    • 2020
  • 최근 기후변화로 인해 가뭄의 규모 및 발생빈도가 증가하고 있는 추세이며, 불특정 다수의 지역에 장기간에 걸친 가뭄 발생이 증가하고 있다. 이에 본 연구는 선제적 가뭄 대응 및 관리를 위해 기후변화에 따른 가뭄 현황과 원인을 분석하고, 전국을 대상으로 일괄적인 가뭄평가를 수행하여 지자체별 가뭄대책 수립이 시급한 지역을 확인하기 위한 가뭄취약지도를 구축하였다. 가뭄취약성 평가는 가뭄대응능력, 노출도, 민감도, 보조수원능력을 기반으로 하여 평가 방법론을 개발하였다. 가뭄 대응능력은 지역별 현재 급수체계를 고려한 물수지 분석을 통해 용수공급 가능일수를 산정하고 점수화하였다. 노출도는 가뭄의 발생빈도와 심각한 정도를 나타내는 가뭄빈도와 가뭄심도를 활용하여 가뭄위해성지수(DHI)를 산정하고 계수화 하였다. 민감도는 생활용수와 공업용수 이용량을 합산하여 생공용수 이용량을 산정하고 계수화 하였다. 마지막으로 보조수원능력은 지역별 주 수원의 기능을 보조하여 가뭄에 대응할 수 있는 지하수 개발 가능량과 저수지 용량을 합산하여 해당지역 생공용수 수요량으로 나눈 값을 계수화 하였다. 4가지의 평가인자를 통한 가뭄취약성 평가는 I-IV등급까지 총 4개의 등급으로 평가된다. I등급은 가뭄취약지도제작 시급성 및 가뭄발생빈도가 낮고, 가뭄의 규모와 피해가 작으며, 용수공급능력이 충분한 지역이며, II등급은 가뭄취약지도의 제작이 다소 시급하며, 가뭄발생빈도가 낮고, 가뭄의 규모와 피해가 작으며, 용수공급능력이 다소 부족한 지역이다. III등급은 가뭄취약지도의 제작이 시급하며, 가뭄발생빈도가 높고, 가뭄의 규모와 피해가 크며, 기존 용수공급 능력이 부족한 지역이며, IV등급은 가뭄취약지도의 제작이 시급하며, 가뭄발생빈도가 높고, 가뭄의 규모와 피해가 크며, 용수공급 능력이 매우 부족하여 별도의 대책이 필요한 지역이다. 개발된 가뭄취약성 평가 방법을 시범적으로 충남 8개 시군에 적용하여 평가 해본 결과, 가뭄대응능력이 가뭄취약성에 가장 중요한 인자로 나타남에 따라 가뭄 대응 및 관리에 있어 가뭄대응능력, 즉 용수공급 가능일수를 높이는 것이 가장 중요한 것으로 판단되었다.

  • PDF

The Reclamation of Secondary Effluent to Industrial Water by Co-60 γ Irradiation (Co-60 γ선을 이용한 하수처리수의 공업용수로의 재이용)

  • Lee, Myun-Joo;Jeoung, Young-Do;Nho, Young-Chang;Shon, Jong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.838-842
    • /
    • 1999
  • In order to reclaim the effluent discharged from sewage treatment facilities application of an irradiation technique was investigated in this study for industrial water reuse. Samples were filtered using a sand filter to remove particles. Co-60 was used as an irradiation source and the irradiation dose was varied from 0.1 kGy to 15 kGy. The major source of colour in secondary treatment effluent was humic substances, which could be easily removed by irradiation with a dose 5 kGy. Bacteria could be also disinfected even at low doses. It was possible to get high quality water for industrial water reuse. But the effluent still contained a small amount of organic compounds. Further treatment, of residual organic compounds will be necessry if the higher quality water is required.

  • PDF

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Drought states visualization considering water use sectors (물이용 특성을 고려한 가뭄상황 표출 방안)

  • Kang, Jaewon;Park, Jisung;Seo, Aesook;Cho, Younghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.363-363
    • /
    • 2017
  • 각 기관에서는 가뭄상황을 모니터링하기 위해서 기관의 역할에 맞는 방식으로 가뭄지수를 산정하여 표출하고 있다. 국민안전처에서는 2016년 3월부터 부처간 협동으로 우리나라의 가뭄 상황을 기상학적 가뭄, 농업적 가뭄, 수문학적 가뭄으로 구분하여 행정구역단위로 주의, 심각, 매우심각의 3단계로 표출하여 활용하고 있다. 저류시설 등을 고려하여 가뭄지수를 도출하고 가뭄을 세가지 속성으로 나누어서 표출하는 것은 타당하지만, 동일한 행정구역 상에서 각 가뭄속성을 표현하는 것은 실제적인 가뭄상황의 판단과 적절한 전략적 대응을 위해서는 개선될 필요가 있다. 본 연구에서는 토지이용도를 기반으로 용수 이용 상황과 용수공급을 위한 사회기반시설을 고려해서 가뭄상황의 표현을 위한 구역의 재설정과 각 구역별로 적절한 가뭄지수의 적용 및 상황파악에 도움을 줄 수 있는 통계적 지표를 동시에 제공할 수 있는 프레임워크를 설계하고 이를 테스트베드를 대상으로 시범적으로 구현하였다. 산림이나 초지 지역, 관개시설에 의한 용수공급을 받는 논지역, 강수의존형 논지역과 밭지역, 광역상수도나 지방상수도에 의한 공급지역, 기타 생공용수 공급지역 등으로 구분하여 기상학적 가뭄, 농업적 가뭄, 수문학적 가뭄 상황이 동일 행정구역내에서도 서로 다른 값을 가질 수 있도록 하였다.

  • PDF

Analysis of the agricultural area conversion of paddy to field based on reservoir irrigation region (저수지 수혜구역단위 논 전작화 패턴 분석)

  • Park, Jin Seok;Jang, Seong Ju;Hong, Rok Gi;Hong, Joo Pyo;Song, In Hong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.467-467
    • /
    • 2021
  • 기존 저수지 농업용수는 주로 논의 벼재배 용수공급을 목적으로 설계되었지만, 논 지역 타작물 재배 지원 등의 정책으로 논에서 밭으로 전작화가 증가함에 따라 농업용수의 효율적 분배를 위한 논의 전작화 패턴 분석이 필요한 실정이다. 이에 본 연구에서는 공공데이터 포털의 2019년 팜맵을 활용하여 최신 경지 현황을 파악하고, 환경부의 2007년, 2019년 토지피복지도를 이용하여 전작화 패턴을 분석하였다. 구축된 팜맵과 토지피복지도는 환경부 토지피복분류 기준 농업지역 중분류로 일치시켜 분석에 활용되었다. 논, 밭, 시설재배지 등의 농경지 이용 현황 및 전작화 추이는 전국 단위, 권역 단위로 분석되었고, 주요 시도와의 공간적 거리를 전작화 영향인자로 설정하여 DUP(Degree of Urban Proximity) 등의 지표로 그 영향을 확인하였다. 또한, 전체 경지 중 논, 밭의 면적과 증감 추이를 ACR(Area Change Rate) 등의 지표로 전작화 규모를 파악하였고, LPI(Largest Patch Index), LSI(Landscape Shape Index) 등의 지표로 개별/집단화 전작의 패턴분석을 수행하였다. 본 연구로 제시된 저수지 수혜 구역별 논의 전작화 패턴은 논 벼재배와 농업용수 수요 특성이 상이한 밭작물에 안정적 용수공급 체계 구축 등의 기초자료로 활용 가능할 것으로 생각된다.

  • PDF

Analysis of Indicator Microorganism Concentration in the Rice Cultural Plot after Reclaimed Water Irrigation (하수처리수 관개후 벼재배 시험구에서 지표미생물 거동 분석)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.112-121
    • /
    • 2004
  • A study was performed to examine the effects of UV-disinfected reclaimed water on microorganism concentration during rice culture. Four treatments were used and each one was triplicated to evaluate the changes of microorganism concentrations: stream water irrigation (STR), biofilter effluent irrigation (BE), UV-disinfected water irrigation with dose of 6 mW ${\cdot}$ s $cm{-2}$ (UV-6), and UV-disinfected water irrigation with dose of 16 mW ${\cdot}$ s $cm{-2}$ (UV-16). The indicator microorganisms of interest were total coliform (TC), fecal coliform (FC), and E. coli. The biofilter effluent from 16-unit apartment sewage treatment plant was used as reclaimed water and flowthrough type UV-disinfection system was used. Concentrations of indicator microorganisms in the treatment plots ranged from $10^2$ to $10^5$ MPN/100 mL during 24 hours after irrigation in May and June, where initial irrigation water for transplanting reparation was biofilter-effluent without UV-disinfection. It implies that initial irrigation using only non-disinfected reclaimed water for puddling in paddy field can be health-concerned because of more chance of farmer's physical contact with elevated concentration of microorganisms. The concentrations of microorganisms varied widely with rainfall, and treatments using UV-disinfected water irrigation showed significantly lower concentrations than others and their levels were within the range of paddy rice field with normal surface water irrigation. The mean concentrations of STR and BE during growing season were in the range of 4 ${\times}\;10^3$ MPN/100 mL for TC, and 2${\times}\;10^3$ MPN/100 mL for FC and E, Coli, While mean concentrations of UV-S and UV-lS were less than 1${\times}\;10^3$ MPN/100 mL for all the indicator microorganisms. Overall, UV-disinfection was thought to be feasible and practical alternative for agricultural reuse of secondary level effluent in Korea.