Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

Multicast Rerouting according to Mobile Host Handover in Internet (인터넷에서 이동 호스트의 핸드오버에 따른 멀티캐스트 경로 재설정)

  • Kim, Yong-Soo;Jang, Kyung-Sung;Kim, Byung-Ki
    • Annual Conference of KIPS
    • /
    • 2000.04a
    • /
    • pp.379-383
    • /
    • 2000
  • 인터넷에서 멀티캐스트 그룹 통신을 하고 있는 이동 호스트가 접속지점을 수시로 바꿈에 따라 지속적인 멀티캐스트 응용에 참여하기 위해서는 이웃하는 멀티캐스트 라우터를 찾아내어 연결을 유지시켜야 한다. 기존 연구들은 주로 멀티캐스트를 지원하는 환경에서만 고려된 것들이다. 그러나 오늘날 대부분 라우터들은 멀티캐스트 서비스를 지원하지 않으며, 기존 연구들에서는 이를 터널링으로 해결하였다. 그런데 터널링은 경로 최적화 문제를 안고 있으며, 호스트 이동성의 본질적인 특성인 투명한 라우팅과 최적의 경로설정에 위배되는 문제점을 안고 있다. 본 논문은 멀티캐스트 기능을 지원하지 않는 망에서도 이동 호스트에게 멀티캐스트 응용 서비스를 제공할 수 있는 MRM-IP 방법을 제안한다. 이 방법은 이동 호스트가 인터넷에서 멀티캐스트 라우터가 장착되지 않는 망으로 이동했을 때, 종단 호스트와의 최적 경로를 이루는 최하단 멀티캐스트 라우터를 찾아 그룹 멤버로 원격가입 함으로써, 유니캐스트 한다. 이는 IETF의 양방향 터널링과 원격가입의 장점만을 이용한 것으로, 경로 최적화 문제를 해결하여 망에서 트래픽 지연을 줄일 수 있다.

  • PDF

Hydrological Characteristic Analysis of Multi-purpose Dam Inflow Considering Climate Change (기후변화를 고려한 다목적 댐 유입량의 수문학적 특성 분석)

  • Kang, Ho Yeong;choi, Ji hyeok;Kim, Jong Suk;Moon, Young Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.149-149
    • /
    • 2015
  • 한반도를 포함한 전 세계가 기후변화로 인한 가뭄과 홍수에 노출되어 있으며, 물 공급의 안정성 확보, 공공시설물과 재산 피해 등 엄청난 직 간접적인 경제적 손실이 발생하고 있다. 유역의 수문학적 거동 특성을 파악하는 일은 가뭄 및 홍수 등의 자연재해를 포함하여 수자원의 효율적 예측과 관리, 안정적인 용수공급 등을 위해 필수적인 요소이다. 특히 극치사상의 특성변화는 하천과 하천주변의 토사유입이나 침전 부유물의 재분포 등 유역 및 하천 생태계의 구조 및 기능에 영향을 줄 수 있는 요소이기 때문에 주의 깊게 살펴볼 필요가 있다. 따라서 본 연구에서는 한반도 다목적댐 중 20년 이상의 일유입량 자료를 보유한 8개 지점에 대해 일별, 계절별 변화와 기저유량에 대한 분석을 실시하였다. 또한, 태풍자료와 유역평균강우량자료를 활용하여 태풍으로 유입된 강우와 비태풍 강우를 분리하였다. 향후 극치사상에 대한 다양한 수문변화분석을 수행함에 있어 태풍과 집중호우 등 변화 요인을 분리하여 원인에 따른 변화를 진단하여 지속가능한 수자원 이용에 기초자료를 제공하고자 한다.

  • PDF

Safety Evaluation of a Wastewater Reuse for the Farmland Irrigation in Jeju Island (제주지역 하수처리수의 농업용수 재이용 안전성 평가)

  • Son, Yeong Kwon;Rhee, Han-Pil;Kim, Haedo;Choi, Sun Wha;Kim, Jeong Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.21-29
    • /
    • 2015
  • Safety of reclaimed wastewater irrigation needs to be evaluated to promote public health. Quantitative microbial and toxic risk assessment was conducted to identify the level of risk for farmland workers who use reclaimed wastewater and groundwater in Jeju island. Microbial risk through inhalation and ingestion exposure was below acceptable level (less than $10^{-3}$) of $7.07{\times}10^{-6}$ for reclaimed wastewater and $9.99{\times}10^{-8}$ for groundwater irrigation worker. Aggregate exposure risk of Ni, As and Cu was most contributable to overall risk in both reclaimed wastewater and groundwater irrigation plot. High cumulative exposure risk was estimated through non-dietary soil ingestion and dermal contact of soil, due to the high concentration of As, Cu and Ni in farmland soil. Overall toxic risk was $2.68{\times}10^{-4}$ for reclaimed water and $2.39{\times}10^{-4}$ for groundwater irrigation, which could not meet acceptable toxic risk level of $10^{-6}$. Further efforts, such as provide personal protective equipments or public health education, need to be implicated to reduce adverse health risk.

Feasibility Study of Intermittent Slow Sand Filtration for Agricultural Reuse of Reclaimed Water (농업적 용수재이용을 위한 간헐분사 완속모래여과 하수재처리 효율 평가)

  • 윤춘경;정광욱;함종화;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.160-170
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of intermittent slow sand filtration for agricultural reuse of reclaimed water. The effluent of biofilter for 16-unit apartment was used as influent to the slow sand filtration system at 0.6 $m^3$/day loading rate using 15 seconds spray in every 10 minutes on the about 1 $m^2$ surface area and 0.5 m depth. The influent concentrations of total coliform (TC), fecal coliform (FC) and E. coli were in the range of 10.000 MPN/100 mL. and they were reduced to less than 1,000 MPN/100 mL after filtration with average of 320, 270, and 154 MPN/100 mL, respectively, showing over 95 % removal. Turbidity and SS were improved effectively and their average concentration was reduced to 0.8 NTU and 1.7 mg/L, respectively, and removal rate was about 50 %. Average BOD and COD concentrations were also reduced substantially to 2.6 and 25.8 mg/L with about 55 and 21 % removal rate, respectively. Nutrients removal was relatively low and removal rate for T-N and T-P was low however, remaining nutrients might be beneficial and less concerned in case of agricultural reuse. The concentration of biofilter effluent used in this experiment was in the range of secondary treatment effluent but slightly stronger than the one from existing wastewater treatment plants (WWTPs). Therefore, intermittent slow sand filtration might be also applicable to the effluent from WWTPs as long as its agricultural reuse is available. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, the intermittent slow sand filtration was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper is a preliminary result from pilot study and further investigations are recommended on the optimum design parameters before full scale application.

Feasibility Study of Wastewater Reuse for the Vegetable Farming in Jejudo (제주도 밭작물의 농업용수 재이용 타당성 평가)

  • Seong, Choung-Hyun;Kang, Moon-Seong;Jang, Tae-Il;Park, Seung-Woo;Lee, Kwang-Ya;Kim, Hae-Do
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • The objective of this study is to assess the feasibility of wastewater reuse for the vegetable farming. The study region, about 250 ha in size, is located on the west coast of Jejudo, Korea. Major agricultural products of the study area are the cabbage, broccoli, garlic and onion. To confirm the feasibility of wastewater reuse, the drought duration and the water requirement analysis were conducted respectively. The average annual precipitation of the study region (1,121 mm) was smaller than that of Jeju island (1,975 mm). The drought duration for a ten-year return period in October through November was more than 20 days. The water requirement for irrigation was calculated by the FAQ Penman-Monteith method which took into account the cultivated crops, planting system, and meteorological conditions of the study region. The water requirement for a ten-year return period was estimated 4.7 mm/day and the water demand for irrigation was $4,584\;m^3/day$. As a result, the irrigation water for the crops was insufficient during their breeding season, especially in October through November. Thus, the result indicated that the study region required the alternative water supply such as wastewater reuse during the non-rainy season. As drought continues to place considerable stress on the availability of fresh water supplies in the study region, irrigation with reclaimed wastewater will play an important role in helping to meet future water demands.

Analysis of Efficiencies in pro environmental constructed Wetlands for Treating sewage treatment effluent (친환경 인공습지 조성을 통한 하수처리 방류수 재처리 효과분석)

  • Lim, Gun Muk;Park, So Mi;Ha, Eun Jung;Lee, Jong Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.220-220
    • /
    • 2020
  • 영산강수계는 상류에 4개의 농업용 댐이 위치하여 환경대응용수 확보 및 하천유지유량이 절대적으로 부족하고, 갈수기 하천 유량의 약 67 %가 광주 제 1, 2 하수처리장 방류수가 차지하고 있어 하천의 수질과 수생태계를 위협하고 있다. 이에 최근에는 오염된 하천의 건강성을 회복하기 위한 방법으로 수생태계의 정화능력을 활용한 인공습지가 각광받고 있다. 영산강 유역에서도 자연의 정화능력을 활용하여 하천 오염원을 저감시키기 위한 사업의 일환으로 2016년 광주 제 2 하수처리장 방류구에 서창오미공원 습지를 조성하였다. 이 습지는 유입량이 적어 정상적 기능이 어려운 기존 습지를 재조성한 것으로 하수처리장 방류수 약 5만 ㎥/day을 습지로 유입시켜 수질정화용 식재식물을 이용하여 하수처리장 방류수 수질을 개선한 사업이다. 2016~2017년 모니터링 결과, 습지 유입 전·후 BOD는 평균 33.5 %, 최대 73.1 % 저감 되었으며, T-P 또한 평균 59.3 %, 최대 91.6 % 저감 되었다. 그러나 습지는 운영기간 경과 시 퇴적물 축적, 고사체로 인한 T-P 용출 등으로 인하여 처리수의 수질이 더 악화될 우려가 있기 때문에 습지 조성 후 지속적인 유지관리와 모니터링이 필요하다. 그 예로 하수처리장 방류수와 비점오염원 처리를 위해 주암호에 조성된 인공습지의 경우, 2001년 준공 후 지속적인 관리 및 모니터링을 통하여 약 17년이 지난 2018년에도 BOD 49.3 % T-N 65.1 %, T-P 19.2 % 로 저감되어 오염원 및 영양염류 제거에 큰 효과가 있는 것으로 나타났다. 따라서 본 조사에서는 서창오미공원과 주암호 인공습지 운영 결과를 토대로 습지 모니터링의 중요성과 적정 운영 방안을 제시하고자 하며, 영산강 하천의 점·비점오염원 저감을 위한 신규 인공습지 조성 사업에 기초자료로 활용하고자 한다.

  • PDF

Transformation of Gourd through Leaf Explant Regeneration (잎 절편의 재분화에 의한 참박 형질전환)

  • Cho, Song-Mi;Moon, Sun-Jin;Chung, Soo-Jin;Kim, Mi-Seong;Kim, Young-Cheol;Yang, Kwang-Yeol;Choi, Yong-Soo;Sapkota, Kumar;Cho, Baik-Ho;Kim, Kwang-Sang
    • Korean Journal of Plant Resources
    • /
    • v.19 no.5
    • /
    • pp.634-639
    • /
    • 2006
  • In order to develop a disease-resistant root stock for the growth of watermelon, an efficient regeneration system of the gourd(Lagenaria leucantha Duch.) inbred line GO701-2 via organogenesis was established in this experiment. Using proximal parts of cotyledon explant excised from germinated seedling in vitro, maximum adventitious shoot formation (39%) was achieved on MS medium where cytokinin (BA) and auxin (IAA) were added at a concentration of 3mg/L and 0.1mg/L, respectively. Roots of the elongated shoots were successfully formed on MS medium without adding any plant growth regulators. The cucumber CsGolS1 gene known as a resistance gene against biotic and abiotic stresses, was constructed into the binary vector pBI121 under the control of CaMV 35S promoter. When the gene was introduced into the genome of gourd by Agrobacterium-mediated transformation, putative transgenic plants were obtained with the transformation efficiency of approximately 20 percent.

Characteristics of Groundwater Quality for Agricultural Irrigation in Plastic Film House Using Multivariate Analysis (다변량분석법을 이용한 시설재배지 지하수 수질 특성)

  • Kim, Jin-Ho;Choi, Chul-Mann;Lee, Jong-Sik;Yun, Sun-Gang;Lee, Jung-Taek;Cho, Kwang-Rae;Lim, Su-Jung;Choi, Seung-Chul;Lee, Gyeong-Ja;Kwon, Yeu-Seok;Kyung, Ki-Chon;Uhm, Mi-Jeong;Kim, Hee-Kwon;Lee, You-Seok;Kim, Chan-Yong;Lee, Seong-Tae;Ryu, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • The main purpose of this study is to accumulate the fundamental data representing groundwater of plastic film houses by means of water quality and its multivariate statistical analysis. Groundwater samples were collected in every two years since 2000 to 2004 from total 211 sites. According to the result of water quality analysis, ground water quality was suitable for irrigation purpose averagely. Correlation analysis showed that EC was highest positively correlated with $Mg^{2+}$ to 0.810(p<0.01), 0.776(p<0.01) in April and July, respectively. $NO_3-N$ was highest positively correlated with T-N to 0.794(p<0.01) in October. This result shows that it can lead to a different result even in similar case sometimes. Four factors were extracted through factor analysis in April and July, but five factors were extracted in October. The proportions of cumulative variance by the factor were 64.9, 60.2, and 70.7 in April, July, and October, respectively. The first factor was highly related to anions and cations such as $Ca^{2+},\;Mg^{2+},\;Cl^-,\;{SO_4}^{2-}$, and EC in contrast to that of stream water. According to the cluster analysis, 211 sites are classified into four groups. Common type of ground water quality was shown in group A. The pH and $PO_4-P$ were highest in Group B. The anions and cations were highest in Group C. $COD_{Cr}$ was highest in Group D.

Assessment of water resources availability considering complex water use in upstream of the Hantan River Dam (한탄강댐 상류 상세 물이용체계를 고려한 수자원가용량 평가)

  • Jang, Cheol Hee;Kim, Hyeon Jun;Kim, Deok Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.252-252
    • /
    • 2020
  • 대하천 주변 광역상수도 공급지역은 가뭄 발생시에도 안정적으로 물이용이 가능하나, 중소하천을 수원으로 하는 하천의 상류지역은 가뭄시 물공급 안정성이 취약하다. 따라서 중소하천을 대상으로 가뭄시 물 공급시설의 효율적 운영, 물부족 위험도 평가, 가용 수자원의 최적이용 등 종합적인 대책 마련을 위해서는 신뢰성 높은 수문량(하천유출량 및 수자원가용량) 예측이 필요하다. 기존의 가뭄시 하천유출량 예측정확도 평가는 통계적 회귀분석을 통한 가뭄지수 기반의 가뭄상황의 예측에 치중하여 불확실성이 크며 국내 유역의 복잡한 물이용체계를 고려하지 않아 시·공간적인 규모에 따라 상이한 결과를 나타내며 실측자료 기반의 하천유출량과 비교하면 정확도가 대부분 60% 이하로 나타난다(이상은 등, 2015). 본 연구에서는 상세 물이용체계를 고려한 정도높은 수자원가용량의 평가를 위하여 한강권역 내의 한탄강댐 상류 유역을 테스트베드로 선정하였다. 한탄강댐 상류유역은 다수의 복잡한 농업용 수리시설 운영에 따른 수자원가용량 예측정확도가 매우 낮은 지역으로 본 연구를 통해 정도 높은 수자원가용량 예측정확도를 확보하기에 적정한 유역이라 판단하였다. 수자원가용량을 평가하기 위한 모형은 한국건설기술연구원에서 개발된 CAT3.1(Catchment hydrologic cycle Assessment Tool 3.1)을 이용하였다. CAT 3.1은 중소하천 유역내의 인위적인 물이용체계(광역급수, 재이용, 지하수 취수, 하천수 취·배수 등)를 반영한 수문량(하천유출량 및 수자원가용량) 평가 및 예측이 가능한 모형으로 기존 개념적 매개변수 기반의 집중형 수문모형과 물리적 매개변수 기반의 분포형 수문모형의 장점을 최대한 집약하여 개발되었다. 한탄강댐 상류유역의 물리적 매개변수는 최대한 기 구축된 GIS 자료를 활용하여 추출하였다. 토지이용현황은 산림과 농업지역이 대부분을 차지하여 농업용수 공급이 대부분인 물이용체계를 가지고 있다. 따라서 한국농어촌공사에서 관리하는 11개 농업용 저수지에 대한 취수현황 및 제원, 국가지하수센터의 유역내 지하수사용량, 하폐수처리량을 기본 입력 자료로 사용하였다. 특히 농업용 저수지의 경우에는 저수지출구점을 기준으로 저수지 상류유역 및 한국농어촌공사에서 기 구축된 관개면적 공간자료를 기본으로 수혜구역을 세분화하여 모형을 적용하였다.

  • PDF