• Title/Summary/Keyword: 요면 영역

Search Result 3, Processing Time 0.016 seconds

Improvement of Active Contour Model for Detection of Pulmonary Region in Medical Image (의학 영상에서 폐 영역 검출을 위한 Active Contour 모델 개선)

  • Kwon Y. J.;Won C. H.;Park H. J.;Lee J. H.;Lee S. H.;Cho J. H.
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.3
    • /
    • pp.336-344
    • /
    • 2005
  • In this paper, we extracted the contour of lung parenchyma on EBT images with the improved active contour model. The objects boundary in conventional active contour model can be extracted by controlling internal energy and external energy as energy minimizing form. However, there are a number of problems such as initialization and the poor convergence about concave part. Expecially, contour can not enter the concave region by discouraging characteristic about stretching and bending in internal energy. We controlled internal energy by moving local perpendicular bisector point of each control point in the contour and implemented the object boundary by minimizing energy with external energy The convergence of concave part could be efficiently implemented toward lung parenchyma region by this internal energy and both lung images for initial contour could also be detected by multi-detection method. We were sure this method could be applied detection of lung parenchyma region in medical image.

  • PDF

Enhanced Gradient Vector Flow in the Snake Model: Extension of Capture Range and Fast Progress into Concavity (Snake 모델에서의 개선된 Gradient Vector Flow: 캡쳐 영역의 확장과 요면으로의 빠른 진행)

  • Cho Ik-Hwan;Song In-Chan;Oh Jung-Su;Om Kyong-Sik;Kim Jong-Hyo;Jeong Dong-Seok
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.1
    • /
    • pp.95-104
    • /
    • 2006
  • The Gradient Vector Flow (GVF) snake or active contour model offers the best performance for image segmentation. However, there are problems in classical snake models such as the limited capture range and the slow progress into concavity. This paper presents a new method for enhancing the performance of the GVF snake model by extending the external force fields from the neighboring fields and using a modified smoothing method to regularize them. The results on a simulated U-shaped image showed that the proposed method has larger capture range and makes it possible for the contour to progress into concavity more quickly compared with the conventional GVF snake model.

An Automatic Extraction of Blood Flow Contour from Cardiac MRI (심장 MRI 영상에서 혈류 윤곽선의 자동 추출)

  • Lee, Hyeong-Jik;Jo, Sang-Hyeon;Choe, Heung-Mun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.5
    • /
    • pp.56-62
    • /
    • 2000
  • In this paper, an automatic extraction of the blood flow contour from cardiac MRI is proposed. By using the GVF snake which has wider capture range than the conventional snake, and by automatically generating the initial points along the outside of the contour of the zero GVF field in the edge image of the cardiac MRI, the blood flow contour can be automatically extracted, even when the contours have boundary concavities due to the papillary muscles, without any manual initialization of the experts. Experiments are conducted on the various real cardiac MRIs including noise and papillary muscles, and the proposed method is proved to be efficient in automatic extraction of the blood contours even if they have the boundary concavities.

  • PDF