• Title/Summary/Keyword: 요골동맥파

Search Result 7, Processing Time 0.018 seconds

Characteristics of Pulse Wave Velocity by the Simultaneously Measured ECG Waveform and Hall Device Radial Artery Waveform (ECG 파형과 홀소자 맥진파형으로 동시 측정한 맥파전달속도 특성 연구)

  • Yoo, Jae-Young;Choi, Suel-Gi;Kim, Dam-Bee;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.136-141
    • /
    • 2012
  • In the this research, two simultaneous peaks of radial artery pulse wave and ECG pulse wave measured by using clip-type pulsimeter and ECG were investigated in order to analyze pulse wave velocity. The measured value of a pulse wave velocity is about 5~7 m/s, it is proved one new method to measure an exact value of pulse wave velocity more than the typical biomedical signal monitoring system. This result implies that data measured by the oriental medical diagnosis apparatus as pulsimeter is clinically used in future.

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.

Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram (홀소자가 구비된 요골동맥 집게형맥진기와 심전도로 측정된 맥파전달속도)

  • Lee, Kyu-Hwan;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.130-134
    • /
    • 2013
  • The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5~7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field (자기장 측정 홀소자 집게형 맥진기를 이용한 허맥과 실맥 예측 알고리즘 개발)

  • Lee, Nam-Kyu;Kim, Keun-Ho;Lee, Sang-Suk;Yu, Ji-Hye;Yu, Jun-Sang;Sun, Seung-Ho;Chang, Sei Jin;Hong, Yu-Sik
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.104-109
    • /
    • 2013
  • Clip-type pulsimeter equipped with Hall device and a minute permanent magnet as sensing the minute movement of a radial artery was developed. The clinical data of the 120 number of subject acquisited through the clip-type pulsimeter did treated with a typical statistical logistic regression analysis. The prediction algorithm for the replete pulse and vacuous pulse was studied. The reflective peak time and the notch peak time were major parameters to discern the replete pulse and vacuous pulse. The discrimination rate was 65%. It suggests that the logistic regression equations are possible to use the diagnosis index to predict and discern the oriental pulse wave.

Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor (홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구)

  • Cho, Hyun-Sung;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.178-182
    • /
    • 2012
  • This research suggested that the extraction of respiratory rate could be made possible by using frequency analysis in the data process for clip-type pulsimeter equipped with permanent magnet and Hall sensor. The pulse analysis included of cardiac motion information depending on variation of pulse waveforms is investigated by means of Fast Fourier Transformation (FFT). The peaks of FFT spectrums measured at 15, 20, 30, 40, and 50 tempos are coincided to each respiratory rate having 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, and 0.41 Hz, respectively. The FFT spectrum using algorithm for the extraction of respiratory rate showed the best pulse waves measured during 300 s. Based upon these results, the clip-type pulsimeter could extract the effective respiratory rate reflecting physical effects.