• 제목/요약/키워드: 외적 비부착

검색결과 7건 처리시간 0.02초

외적 포스트텐셔닝 강봉으로 보강된 철근콘크리트 보의 ABAQUS를 이용한 비선형해석 (Nonlinear Analysis using ABAQUS Software of Reinforced Concrete (RC) Beams Strengthened with Externally Post-tensioning Steel Rods)

  • 이수헌;신경재;김진욱;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.11-17
    • /
    • 2018
  • Concrete is the well-used material in many architectural and civil structures. The behavior of concrete does exhibit a different characteristic in compression and tension, and it also shows an inelastic-nonlinear behavior. In addition, the concrete properties vary slightly depending on the environmental factor and manufacturer. These properties of concrete make the modeling or simulation of concrete material difficult. In reinforced concrete, particularly, there is a difficulty in bond-slip relationship between concrete and steel. However, in this paper, reserving remainder of these limits the finite element analysis for reinforced concrete beams through ABAQUS simulation has been carried out with some assumptions. Assumptions include the perfect bond of steel and concrete as well as the concrete damaged plasticity (CDP) in concrete property. There is a reasonable agreement between the experimental and numerical results, although the analytical strength and external rod deformation are slightly overestimated. The average and standard deviation between two results are 1.05 and 0.05, respectively. And the models and the computations lead to the evolution of fracture in bending beam.

스마트 건설기반 번들네일의 축응력 평가 (Axial Stress Evaluation of Bundle Nails in Smart Construction)

  • 이동혁;류재구
    • 한국지반환경공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.13-17
    • /
    • 2024
  • 현재 국내외적으로 토사사면의 사면안정을 위해 사용하고 있는 일반 Soil Nailing은 지반을 천공 후 단일 철근을 활용, 그라우팅하여 일종의 중력식 옹벽을 형성하여 사면의 안정을 도모하고 있다. 이러한 공법을 공사비 절감과 시공의 용이성, 상대적인 강도와 변위면에서 우수한 효율을 낼 수 있는 공법이다. 동일한 공종으로 진행하되 단일 철근을 다발철근으로 변경하여 활용할 경우 항복 인발력에 대한 그라우팅과 철근의 부착력 차이, 동일한 인발저항 대비 변형량의 차이를 현장시험을 통해 분석하여 공학적 우수성을 규명하고 공사비 측면에서 강도정수가 동일한 지반에 대하여 저항력이 동일하게 적용할 경우, 천공수의 차이와 재료비 등 전체 공사비에 미치는 영향분석을 통해 절감효과의 비교를 분석하여 평가하였다.

금속나노입자 기능화된 산화물 나노선 센서의 감응특성

  • 최선우;정성현;박재영;김상섭
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.33.2-33.2
    • /
    • 2010
  • 산화물 반도체 나노선 가스센서는 기존의 벌크 및 박막재료에 비해 체적-표면적비가 매우 커서 극미량의 화학물질에 대한 감응특성이 유리하여 많은 각광을 받고 있다. 현재, 다양한 물질들의 나노선 합성 및 센서 소자 구현에 대한 연구가 국내외적으로 활발하게 진행되고 있다. 이와 같은 나노선 센서의 실용화를 위해 특정 물질에 대한 선택성과 감응특성의 증진이 여전히 요구되고 있으며, 이에 대한 여러 방향에서의 연구가 진행되고 있다. 특히, 촉매특성이 뛰어난 귀금속 나노입자를 나노선 표면에 부착시킨, 기능화된 나노선 센서소자에 관련된 연구가 활발하다. 본 연구에서는 기상법을 이용하여 합성한 산화물 나노선에 감마선을 조사하여 Au, Pt 및 Pd 금속나노입자를 형성시켰다. 이와 같이 금속나노입자가 고착된 산화물 나노선의 미세구조와 가스 감응특성을 조사하였으며, 기능화된 금속 나노입자가 가스 감응에 미치는 영향과 가스 감응 메커니즘을 제시하고자 한다.

  • PDF

외적 비부착강선을 가진 프리스트레스트 콘크리트 보의 극한휨거동 해석 (Study on the Ultimate Flexural Behavior Analysis of Prestressed Concrete Beam with External Unbonded Tendons)

  • 오병환;유성원;신정성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.662-667
    • /
    • 1998
  • Recently, the using PSC with external unbonded tendons is increased. However, the behavior of external unbonded tendons is different with that of bonded internal tendon at ultimate state by compatibility condition, the slip with friction at deviator and the change of tendon eccentricity e.t.c., So, the analytical research considered the effect of these inherent characters was performed and the tendency of external unbonded tendons was estimated by numerical examples. By the analytical results, load-deflection relationship and stress increment of external unbonded tendons were similar to those of internal bonded tendon at initial elastic behavior state. Those characters were, however, smaller than those character of internal bonded tendons. For external unbonded tendons, if the 1 deviator which is positioned at maximum moment point and more 2 deviators which are position between maximum moment point and support are existed, the flexural behavior is similar to internal bonded tendons.

  • PDF

외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과 (Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

FRP가 외부부착된 철근 콘크리트보의 시간의존거동에 관한 실험적 연구 (An Experimental Study on Time-Dependant Behavior of RC Beams Strengthened with FRP)

  • 김성후;진진율;김광수;한경봉;박선규;송슬기
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.41-44
    • /
    • 2008
  • Fiber Reinforced Plymers (FRPs)는 기존 보수 보강재료에 비해 높은 강도, 내부식성, 절연성등 뛰어난 역학적 특성으로 인하여, 최근들어 기존 구조물의 보수 및 보강에 FRP를 이용한 외부부착 공법 이 활발하게 사용되어지고 있다. 현재 국내 외적으로 FRP 재료를 이용한 외부부착 공법이 적용된 철근 콘크리트보에 관한 연구는 활발히 진행되고 있으나 시간 의존적 거동에 관한 연구는 아직 미흡한 실정이다. 이에 대하여 본 연구에서는 무보강 RC보, Carbon Fiber Reinforced Plymers(CFRPs) 와 Glass Fiber Reinforced Plymers (GFRPs)로 보강된 철근콘크리트보 실험체를 제작하여 약 300일간 25KN의 지속하중을 받은 FRP 보강보의 시간경과에 따른 처짐, 변형률 그리고 온도 변화의 영향을 관찰하였다. 실험 결과 CFRP로 보강된 실험체는 GFRP로 보강된 실험체보다 시간의존적 거동에 있어 더 우수한 보강성능이 있음을 확인할 수 있었다.

  • PDF

강선량 및 긴장력에 따른 외부 강선을 가진 PSC 보의 휨거동 실험 (Experiment of Flexural Behavior of Prestressed Concrete Beams with External Tendons according to Tendon Area and Tendon Force)

  • 유성원;양인환;서정인
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.513-521
    • /
    • 2009
  • 최근 들어 외부 강선을 이용한 프리스트레스트 콘크리트구조물의 건설이 증가하고 있다. 그러나 극한거동 해석시 단면 적합조건을 이용하는 내부 부착 강선과는 다르게 외적 비부착 강선은 부재의 전체거동에 의해서 응력 증 가량이 결정된다. 또한 편향부에서의 미끌림 효과와 강선의 편심 변화 효과 등이 발생하게 된다. 따라서 본 연구는 외 부 강선을 가지는 프리스트레스트 콘크리트(PSC) 보의 거동 특성을 평가하기 위하여 강선량, 긴장력 등을 변수로 하여 정적 휨실험을 수행하여 외부 강선 부재의 휨거동 특성을 얻었다. 실험 결과에 의하면 균열발생 이전의 외부 강선 PSC 부재는 부착 강선 PSC부재와 거동 차이가 크지 않음을 알 수 있었다. 그러나 균열이 발생한 이후의 거동에서는 철근의 항복하중, 극한하중, 강선 응력 등이 외부 강선 부재에서의 값이 부착 강선 부재에 비해서 작게 나타나고 있다. 하중-강 선 변형률 관계에서 보면, 외부 강선 부재들의 경우, 하중 증가에 따른 외부 강선 변형률의 증가량은 초기 긴장력의 크 기 순서와 거의 반대의 순서로 외부 강선의 변형률이 증가한 것으로 나타났으나, 다만 초기 긴장력이 크다할지라도 강 선의 유효응력이 작은 경우의 강선 변형률은 강선의 유효응력이 큰 부재들보다는 다소 작게 증가하고 있는 것으로 나 타났다. 외부 강선 부재의 콘크리트에 발생된 압축 변형률의 크기는 외부 강선의 유효응력 크기 순서와 일치하는 것으 로 나타나, 콘크리트의 압축변형률은 외부 강선의 유효응력에 비례함을 알 수 있다. 실험 결과와 기존의 설계식과 비교 해본 결과, ACI-318에 의한 결과는 긴장력 혹은 유효응력이 차이를 전혀 반영하지 못하고 있고 특히, 그 결과가 실험 결과보다 상당히 작게 나타나, 지나치게 보수적인 것으로 판단된다. 한편 AASHTO 1994는 ACI-318과는 다르게 강선량, 초 기 힘 및 유효응력 등의 변화에 적절하게 영향을 받고 있는 것으로 나타났지만 내부 비부착 강선의 실험 결과를 이용 하여 작성된 이유로 외부 강선 실험 결과보다 지나치게 큰 결과를 유발하고 있는 것으로 평가된다. 이러한 이유로 외 부 강선의 극한응력을 정확하게 예측할 수 있는 새로운 규정이 필요하다.