• Title/Summary/Keyword: 외부제어

Search Result 1,394, Processing Time 0.024 seconds

Study on the Crack Control Effect of Moist Curing Equipment in Side Wall of Building (습윤양생 장치를 이용한 아파트 측벽 균열제어에 관한 연구)

  • Kim, Dae-Geon;Lee, Dong-Woon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2017
  • In this study, moist curing equipment was used in the exist gang-form system. By achieving sufficient spray curing, the quality of the concrete was improved and the cracking occurred in building's side wall was decreased. The following results could be made as the conclusion. For the compressive strength, all zones showed the similar results. Comparing with the zone without using moist curing equipment, the zone used moist curing equipment showed higher rebound hardness results. For the cracking, the zone utilized moist curing equipment showed the cracking averaged as 6.6 m and the zone without using moist curing equipment showed the cracking averaged as 10.3m. The effectof reducing cracking by utilizing moist curing equipment is about 36 %. Using moist curing equipment is considered as a good solution to reduce the cracking in the structure. Considering all the factors analysed, using moist curing equipment improved the quality of the concrete and decreased the cracking. When this equipment was used in the construction site, it is expected that the construction periodcan be shrunk and the ratio of defect caused by drying shrinkage can be decreased. In this research conditions, The 0.3mm sized moist curing equipment provided the most desirable results on concrete quality and preventing cracking.

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.

Implementation of CiA 406 Device Profile for CANopen Compatible Encoders (CANopen 지원 엔코더를 위한 CiA 406 장치 프로파일 구현)

  • Hwang, Hyunbum;Ahn, Hyosung;Kim, Sanghyun;Kim, Taehyoun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1287-1295
    • /
    • 2015
  • Recently, fieldbus communication technologies have been widely deployed for industrial automation because they are profitable in providing easy system integration and management for multiple devices, as well as high-speed communication. It is essential for smart encoders to support fieldbus connectivity, where the device configuration and various types of information related to position are exchanged between an external controller and multiple encoders over the communication link. In this study, we implemented the CiA 406 device profile for smart encoders from the CANopen standards by extending an open-source CANopen standard-compliant framework, called CanFestival. The CiA 406 functionalities implemented in this study were validated on a test-bed consisting of a CANopen master and virtual CANopen encoders with our CiA 406 extension module.

A Study on the Development of a Welding Carriage System for Vertical Weld (수직 용접을 위한 용접 캐리지 시스템 개발에 관한 연구)

  • Byun, Hong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.246-254
    • /
    • 2016
  • Thick-shell welding for super-sized oil storage tanks is currently done manually, which causes deterioration in quality and a lack of uniformity due to frequent rewelding. The limitations of the external environment must also be considered for manual welding. This paper describes the development of a carriage system for automatic vertical welding to increase reliability, reduce cost, and enhance productivity. The system consists of a welding platform, carriage device, and control unit, which were conceptually designed according to design specifications and manufactured with modular parts. In addition, the structure was analyzed for safety and to predict design problems in advance, and the results are reflected in reviewing the design. To evaluate the performance of the system, a tensile test, bending test, and weld time test were carried out, and the results were satisfactory. The time required for automatic weld was greatly improved by more than 87%, compared to the manual welding time.

Primary Malignant Melanoma of the Vagina: A Case Report (질의 원발성 악성 흑색종: 증례보고)

  • Jang Ji-Young;Kim Do-Kang;Lee Eun-Hee;Kim Jun-Sang
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.245-249
    • /
    • 2003
  • A primary malignant melanoma of the vagina is a very rare gynecological malignant tumor. Its clinical behavior is more aggressive than that of cutaneous and vulvar melanomas. We present a case of a large sized primary melanoma of the lower third of the vagina, with a cervical lesion, in a 58-year-old postmenopausal woman. The patient was treated with conventional external radiation therapy and intracavitary radiotherapy (ICR), without surgical treatment. Although the primary lesion showed a partial response, the patient died of extensive metastases, which were found 4.5 months after the initial diagnosis. We suggest that shortening the treatment period, such as hypofractionated radiation therapy and surgical removal, and various systemic therapies for preventing early distant metastasis, are appropriate treatments for a primary malignant melanoma of the vagina, with a large tumor size.

A Design of ALE-compliant RFID Middleware System (ALE 기반 RFID 미들웨어 시스템 설계)

  • Hong, Yeon-Mi;Cho, Yoon-Sang;Byun, Ji-Woong;No, Young-Sik;Park, Sang-Yeol;Oh, Sang-Hyun;Byun, Yung-Cheol
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.469-473
    • /
    • 2006
  • Nowadays, to realize ubiquitous computing environment, many research activities have been going on within various kinds of research domains including automatic identification, sensor network, home network, telematics and so on. Especially, RFID middle-ware that supports the aggregation of RFID tag data, control and management, and the integration with legacy systems has recently gained a lot of attention. Meanwhile, EPCglobal defined an ALE(Application Level Events) standard specification, which exists between RFID readers and applications, and substitutes the previous systems called Savant. In the specification internal structures and implementation technologies of ALE are not mentioned and only external interfaces are defined. This approach easies the verification of standard compliance and inter-operability of the layer. In this paper, we present the design of ALE-compliant RFID middle-ware systems that process RFID tag data efficiently.

  • PDF

Effect of applied magnetic fields on Czochralski single crystal growth (Part II) (Czochralski 단결성 성장특성제어를 위한 자장형태에 관한 연구 (Part 2))

  • Chang Nyung Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.1
    • /
    • pp.46-56
    • /
    • 1994
  • The characteristics of flows, temperatures, concentrations of the boron are numerically studied when uniform axial magnetic fields are applied in the Czechralski crucible. The to governing factors to the flow regimes are buoyancy, thermocapillarity, centrifugal forces, magnetic forces, diffusion coefficient and segregation coefficient of the boron. Since the concentration of the boron is so low that buoyancy effects are negligible, it cannot affect the flow and temperature fields. From the fact that the flow fields are rotationally symmetric, two velocity components in the meridional plane and the circumferential velocity are calculated together with the temperature in the steady state. Based on the known velocity and temperature distributions the unsteady concentration distributions of the boron are calculated. As the strength of the magnetic is increased, the flow velocities are decreased. Circumferential velocities are large near the crucible side-wall and in the region below the rotating crystal. Steep temperatures gradient near the edge of the rotating crystal causes the Marangoni convection. It has been found out that the convection characteristics affects the unsteady transport phenomena of the boron.

  • PDF

Theraml Analysis of the Heat of Hydration in Concrete with Considering Heat Reduction Techniques (온도저감 공법을 고려한 콘크리트의 수화열 해석기법에 관한 연구)

  • 김진근;김국한;양주경
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.176-185
    • /
    • 1995
  • The heat generation of hydration of cement causes the internal temperature rise and volum& change at early age, particularly in massive concrete structures. As the results of the temperature rise and external restraint conditions, the thermal stress may induce cracks in concrete. Therefore, various techniques of the thermal stress control of the mass concrete have been wid'dy used. One of them is pipecooling which reduces the temperature of concrete with flowing water. The objective of this paper' is to develop a finite element program which is capable of simulating the temperature history considering pipe-cooling effect. The numerical results in this study are in good agreement with experimental data measured in the footing(l1 x22m). Therefore, this study may provide available method to predict the hydration temperature of concrete with pip:-cooling.

A study on the implementation of the wireless video security system (무선 영상보안시스템 구현에 관한 연구)

  • Kim, Young-Min;Kim, Myeong-Hwan;Kim, Sun-Hyung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.1
    • /
    • pp.99-104
    • /
    • 2012
  • In this paper, implementation of a wireless video security system relates to a situation outside of using infrared sensors to detect changes when using Zigbee network security in the area of the sensor sends information to the server. The server can judge the situation if an emergency situation through the IP network security camera shot of the area to be transferred command to pantilte. The camera images and information in the security area, sent to administrator's smartphone users to control the camera can see the situation and More than a small video security system was designed so that user can monitor the security zone. Finally, for real-time to identify and respond to emergency situations based on the available wireless networks for video surveillance systems were verified through research and implementation.

  • PDF

Wave Control by an Array of N Bottom-Mounted Porous Cylinders (N개의 투과성 원기둥 배열에 의한 파랑제어)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.4
    • /
    • pp.232-241
    • /
    • 2003
  • The interaction of incident monochromiatic waves with N bottom-mounted porous circular cylinders is investigated in the frame of three-dimensional linear potential theory. The fluid domain is divided into N+l regions i.e. a single exterior region and N interior regions, and the diffraction potential in each fluid region is expressed by an eigenfunction expansion method (Williams and Li,2000). The analytic results show that the porous structure reduces both the wave forces and the run-up wave around the cylinder. To verify the developed model, the systematic model test with a line array of porous cylinders is conducted at the wave tank (30m$\times$7m$\times$1.5m). The analytic results are in good agreement with the experimental results within measured frequency range. It is concluded that the breakwater constructed with an array of porous circular cylinders shows the performance of an effective wave barrier together with the seawater-exchange effect and is considered to have vast potentials for the use of seawater-exchanging breakwater in the future.