• Title/Summary/Keyword: 외부접합부

Search Result 121, Processing Time 0.026 seconds

Enhancing Seismic Performance of Exterior R.C. Beam-Column Connections Using Headed Bars (헤디드 바를 사용한 외부 철근콘크리트 보-기둥 접합부의 내진성능 향상)

  • Shin, Hyun Oh;Yang, Jun Mo;Yoon, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.186-194
    • /
    • 2011
  • The reinforced concrete beam-column connections are in lack of constructability and are likely to show anchorage failure because of the complex details of joint regions. Under seismic loads, a destruction of the column or the beam-column joint leads to collapse of the whole structures. For this reason, the safety of structures has to be guaranteed by following procedures which are based on the strong column-weak beam design concept: 1) failure of beam by generating plastic hinge in the beam maintained a certain distance from the surface of column, 2) failure of column or beam-column joint. In this study, headed bars were used as longitudinal reinforcements of beam and joint reinforcements in order to improve the strength and constructability of joint and to relocate plastic hinge. The finite element analyses (FEAs) were performed to the reinforced concrete beam-column joints utilizing headed bar reinforcements. To verify the availability of the analysis models, the FEAs for experimental tests performed by previous researchers were conducted and compared with the experimental results. Additional variables are also considered to confirm the excellence of headed bars. Analysis results indicate that the constructability of beam-column connections can be improved by using headed bars for the full anchorage of longitudinal reinforcements of beam under similar structural performance. In addition, the plastic hinge was relocated to the intended place by using headed bars as joint reinforcements. Under cyclic displacement loading, the energy dissipation capacity and ultimate stress were increased and the decrease in stiffness was minimized.

A Study about Resistibility of Extracting Nails from Metal Connections on Wood According to Change of Temperature and Humidity (온·습도 변화에 따른 목재 철물 접합부의 못 뽑기 저항성)

  • Kim, Chong-Gun;Park, Cheul-Woo;Yoon, Tae-Ho;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.119-127
    • /
    • 2013
  • In cases of wooden structure and wooden house installed on the outside, metal goods used for basic connection are usually screw bolts, strainless nails and general iron nails. As metal connections on wood are directly exposed to exterior environment, friction resistibility of nails on metal connections declines and continual defects on this are generated and maintenance for it is required. However, experiments and analyses for preparing basic data for improvement of the problems have been not conducted so far and wooden structures with defects are abandoned. Accordingly, by analyzing friction resistibility of connections by each kind of woods and metal goods, the study aims to suggest to use metal goods appropriately by kinds of woods and manufacture conditions with analysis on characteristics of resistibility of extracting nails for solving such problems and to secure basic data for establishing maintenance, repair and reinforcement plans.

An Experimental Study on Shear Strength of RCS System Beam-Column Jointswith Various Transverse Beam Sections (직교보 단면크기 변화에 따른 RCS구조 보-기둥 접합부의 전단내력에 관한 실험적 연구)

  • An, Jae-Hyeok;Park, Cheon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.197-204
    • /
    • 2006
  • Recently, in order to realization of construction and economical saving, various studies are progressing. Also, the study on RCS system which is consisted of reinforced concrete column and steel beam is progressing actively. Actually, however, resisting mechanism of panel zone is influenced by transverse beams when the stress transfers inner panel to outer panel but existing literature didn't reflect the effect of transverse beams. This paper is to analyze the test result of five inner beam-column joints specimen with a variable such as web, flange thickness of transverse beam and face bearing plate(FBP) for RCS systems were tested under cyclic loadings conforming to NEHRP recommendation to investigate the effect of transverse beams and the structural performance of beam-column joints. From the test result, it was shown that transverse beams are effective to enhance the shear strength and structural performance of beam-column joints.

Behavior of Non-seismic Detailed Low-Rise R/C Exterior Beam-to-Column Joints Subjected to Cyclic Loading (반복 하중을 받는 비내진 저층 RC 구조물의 외부 기둥-보 접합부의 거동)

  • Sur, Man-Sik;Chang, Chun-Ho;Kim, Young-Moon
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Seismic design code has been performed since 1988 in Korea, so it has not been applied to low-rise reinforced concrete buildings which had been built before 1988. Those building have been designed only for gravity loads based on non-seismic code, Therefore, even minor earthquake occurred, those buildings might have serious damages. In this paper, to investigate the behavior of low-rise reinforced concrete moment resisting frame which had been built in according to the building code of Korea that had been published before 1988, two type of 1/2 scaled exterior beam-column subassemblies which have non-seismic detailing based on the building code of Korea were constructed and tested with reversed cycling loading under the displacement control method. The special features of joint with non-seismic detailing is that there is no transverse reinforcement in the joint. In tests, cracks pattern, strength degradation, loss of stiffness, energy dissipation and the slippage of beam and column bars were investigated. Cracks did not occurred in the joint even seismic loading of 0.12g which is considered as peak ground acceleration in Korea was applied. And increasing seismic loading above 0.12g shear crack happened in the joint which have not transverse beam.

Inelastic Behavior of Post-tensioned Wide Beam System with different Reinforcement ratios within Column core (포스트텐션을 도입한 넓은 보에서 기둥 폭 내부에 배근된 보강재의 정착비에 따른 비탄성 거동 평가)

  • Choi Yun-Cheul;Lim Jae-Hyung;Moon Jeong-Ho;Lee Li-Hyung;Kwon Ki-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.85-94
    • /
    • 2005
  • Post-tensioned Precast concrete System(PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with floor concrete cast on the PC shell beam and post-tensioning. The purpose of this paper is to evaluate the response of PPS interior beam-column joint subjected to cyclic lateral loading. To this end, an experimental investigation was performed with three half-scale specimens of interior connection. The design parameters are the amount of beam reinforcement placed inside the joint core. The test results showed that cracks were distributed well without my significant degradation of strength and ductility. Also, it was found that the prestressing may affect to alter the torsional crack angle. And the specimens sufficiently resist up to limiting drift ratio of 0.035 in accordance with the provisional by ACl of acceptance criteria for concrete special moment frames.

Influence of Column Aspect Ratio on the Punching Shear Strength of Flat Plate Slab-Column Edge Connections (플랫 플레이트 슬래브-외부기둥 접합부의 뚫림전단강도에 대한 기둥 형상비의 영향)

  • Shin, Sung-Woo;Choi, Myung-Shin;Kim, Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • The aim of this study is to investigate punching shear strength of exterior connections in the flat plate structure with rectangular column. To inspect the effect of column aspect ratios on the punching shear behavior, eight specimens for exterior connection were made and tested. In this experimental program the length of critical perimeter was kept constant, while column aspect ratio varied from 2.0 to 4.5. Two levels of concrete strength and slab reinforcement ratio were also considered. As the column aspect ratio increased, the punching shear strengths are decreased. The decrement of punching shear strength was small in specimens with high aspect ratio of column.

An Experimental Study on Thermal Prestressing Method for Strengthening Concrete Bridge (콘크리트 교량의 보강을 위한 온도 프리스트레싱 공법의 실험적 연구)

  • Ahn, Jin-Hee;Kim, Jun-Hwan;Choi, Kyu-Tae;Kim, Sang-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2007
  • Traditional external post-tensioning method using either steel bars or tendons is commonly used as a retrofitting method for concrete bridges. However, the external post-tensioning method has some disadvantages such as stress concentration at anchorages and inefficient load carrying capability regarding live loads. Thermal prestressing method is a newly proposed method for strengthening and rehabilitation of concrete girder bridges. Founded on a simple concept of thermal expansion and contraction of steel, the method is a hybrid method of external post-tensioning and steel plate bonding, combining the merits of two methods. In this paper, basic concepts of the method are presented and an illustrative experiment is introduced. From actual experimental data, the thermal prestressing effect is substantiated and the FEM approach for its analysis is verified.

Experimental Study on the Behavior of Hybrid Beam-Column Joints Consisted of Reinforced Concrete Column and Steel Beam (철근콘크리트 기둥 및 철골보로 구성된 복합구조의 접합분 거동에 관한 실험적 연구)

  • Choi, Keun-Do;You, Young-Chan;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.297-304
    • /
    • 2003
  • This paper presents the test results of RCS(Reinforced Concrete Steel) beam-column joint with various types of transverse reinforcements such as small-column-type transverse reinforcements, four-piece ㄱ-shape assembled hoops and four-piece ㄱ-shape welded hoops. Five interior beam-column joint specimens were tested to examine the seismic performance and the shear strengths. From the test results, it was found that all the specimens sustained their strength at large levels of story drift(${\theta}$=0.035) without significant loss of strength and stiffness. Therefore it was concluded that the seismic performance and shear strength of the proposed RCS joint are at least the same as those of the specimen with conventional reinforcing details. Also, the contribution of the outer panel to the shear strength of the joint should be evaluated by the compression strut mechanism rather than compression field mechanism.

Feasibility Evaluation of CHS Diagrid Systems for Low/Mid-Rise Building Structure (원형강관 다이아그리드 시스템의 중저층 건축구조물 적용 타당성 평가)

  • Gam, Sam-Do;Kim, Tae-Jin;Kwak, Jin-I
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.84-87
    • /
    • 2009
  • 본 논문에서는 최근 초고층 건축물에 많이 활용되어지는 기둥-가새 시스템인 다이아그리드 시스템을 활용하여 중저층 건축물에 적용가능성을 평가하였다. 본 시스템은 튜브구조의 형태로 횡력에 대한 저항력이 우수하며 중력하중과 황하중을 기초와 지반에 안전하게 하중을 전달한다. 다이아그리드는 경사기둥과 보를 반복적으로 삼각형 형태로 배치되어 중력하중을 받을 경우 수직부재는 압축력을 보는 인장력을 받게 된다. 경사기둥과 보를 연결하는 접합부는 H-형강으로 설계 시 제작이 복잡하고 외관이 좋지 않다. 하지만 원형강관을 사용 할 경우 복합하지 않은 형태로 설계가 가능하고 외관이 우수하기 때문에 외부에 노출이 가능해진다. 또한 원형강관은 개방형 단면 부재에 비해 압축좌굴과 비틀림에 대한 성능 등이 우수하여 구조적인 성능이 우수하다. 원형강관을 이용하여 다이아그리드 시스템이 고층 건축물 뿐만 아니라 중저층 건축물에도 적용 타당성을 검토하였으며 원형강관 접합부 설계는 한계상태설계법이 사용 된 KBC2008(안)을 이용하여 설계하였다.

  • PDF

High Density Energy Welding of Gas Turbine Alloys

  • Kim, Hwan-Tae
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.140-142
    • /
    • 2001
  • 항공기의 제트 엔진을 비롯하여 육상용 발전기, 선박용 엔진, 로켓 엔진 등에 널리 사용되는 터빈 블레이드를 포함한 고온용 가스터빈 부품은 최대 온도 120$0^{\circ}C$ 이상의 고온에 노출되어 가혹한 기계적 응력을 받는 동시에 고온에서의 표면 안정성이 요구되므로 초내열 니켈 합금(superalloy), 티타늄 합금, 내열강 등의 고온강도가 우수한 합금이 사용된다. 그런데 합금성분이 많이 첨가된 내열 합금을 용접하는 경우, 미세균열, 용접부의 기계적 성질의 저하, 용접열영향부의 내식성과 내산화성의 저하, 용접외부 결함에 의한 피로강도 저하 등의 문제가 발생하므로 이를 해결해야 한다. 본고에서는 생산성과 용접품질이 우수한 고밀도 에너지빔 용접의 적용 현황에 관하여 고찰코자 한다.

  • PDF