• Title/Summary/Keyword: 외벽

Search Result 484, Processing Time 0.025 seconds

Research on the Color Design by Building Use for the Classification of Tourism and Residential Areas - On Example of Building Color of Huinnyeoul Culture Village in Busan, Korea (관광 및 주거지역 구분을 위한 건축용도별 색채 디자인에 관한 연구 - 한국 부산 흰여울문화마을의 건축 색채를 중심으로)

  • Zhang, Ning;Yang, Ziqi;Zhou, Ying
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.153-161
    • /
    • 2021
  • The exterior color of the building reflects its style. With the advancement of the 'Village Art' project in South Korea, many villages have gradually developed into tourist attractions. Therefore, it is also important to distinguish between residents' lifestyles and tourist needs through architectural color design. This article first investigates the literature and analyzes the use function of the building and the role of the exterior color in the villages. Secondly, the four types of buildings in Huinnyeoul Culture Village: residential, commercial, leisure, and public toilets are investigated as the research objects. Analyze through the KSCA color measurement analysis system and questionnaire survey, and propose a color plan for the exterior of the building. Research results: First, the main color area of the outer wall of the residential building should be the largest, with a tendency of high brightness and low saturation. Second, small buildings with high chroma in the recreation area can be used as visual guidance.Third, the buildings in the commercial area are mainly of high brightness, high chroma, and multi-hue. Fourth, the main color of the bathroom is the main color of the residential area and the leisure area, which can provide a sense of visual stability.

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

A Study on the Reduction of Falling Deaths Using 4M (4M을 활용한 떨어짐 사망사고 저감 방안 연구)

  • Kim, Seung Eun;Park, Jong Young;Kim, Young Kweon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.143-153
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze data from the Ministry of Health, Safety and Health and the Ministry of Employment and Labor, and the total number of deaths (disease + accidents) reached 2,020 in 2019 and the estimated economic loss was 27.6 trillion won. This is believed to be the time to present improvements to ensure that economic loss estimates are steadily increasing as in Table 1, and that government-level losses can be drastically reduced. Method: In this study, factors were selected through prior research, and reliability analysis, technical statistics and correlation analysis, and multi-term analysis were conducted through the Jamovi program for the analysis of results. Result: Multiple session analysis was conducted to verify the research theory indicated in this study, and the analysis showed that mechanical and management factors did not affect the fall death accident of the opening, and human factors, material and environmental factors had a static effect. In addition, mechanical and administrative factors do not affect the fall of the outer wall, and human and material and environmental factors have a static effect. Conclusion:: As a result of analyzing 450 falling deaths over the past 13 years among the data posted to the Korea Health and Safety Corporation, the most common causes of falling deaths were the openings and outer walls.

An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings (건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Recently, the insulaton design standards for reducing the energy use of buildings have been strengthened. Althoug insulation work is the most cost-effective method for reducing the primary energy consumption per unit area of a building, there are no evaluation criteria for insulation performance at the time of construction and completion inspection. The purpose of this study is to provide objective data by establishing a standard for an analysis method and a method for easily experimenting with the exterior wall thermal transmittance of an apartment house using a thermal transmittance measuring device(TESTO 435). For the exterior wall of the test subject, the specific heat per unit area exceeded 20kJ/(m2·K), and the data at the end point suitable for ISO 9869-1 were analyzed by the average method. The measured values of the thermal transmittance for 3 consecutive days converged within +5% of the desing value, and the standard deviation of the thermal transmittance by day decreased in the order of 1-Day > 3-Day > 2-Day. The standard deviation of the thermal transmittance by time period decreased in the order of 00:00~24:00 < 19:00~07:00 < 00:00~07:00. The measured value of the thermal transmittance for the time perion of 00:00 to 07:00 per day almost coincided with an error of -3% to + 2% compare to the desing value.

One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow (공기와 물의 이상 자연순환 유동의 1 차원 해석)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Jae-Cheol;Hong, Seong-Wan;Kim, Sang-Baik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

Natural Circulation Flow Investigation in a Rectangular Channel (사각 단면 채널에서의 자연순환 유동에 관한 연구)

  • Ha, Kwang-Soon;Kim, Jae-Cheol;Park, Rae-Joon;Kim, Sang-Baik;Hong, Seong-Wan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3086-3091
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled-down as the half height and 1/238 rectangular channel area of the APR1400 reactor vessel. As the water inlet area increased, the natural circulation mass flow rate asymptotically increased, that is, it converged at a specific value. And the circulation mass flow rate also increased as the outlet area, injected air flow rate, and outlet height increased. But the circulation mass flow rate was not changed along with the external water level variation if the water level was higher than the outlet height.

  • PDF

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Evaluation of the Cochlear Electrode Behavior in the 3D Human Cochlea Model by FEM Analysis (3차원 달팽이관 모델에서의 인공와우 전극의 거동에 대한 유한요소해석)

  • 임윤섭;박세익;김용협;오승하;김성준
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.207-215
    • /
    • 2004
  • A finite element analysis is used in this study to model 6 kinds of electrode by a genetic program in order to evaluate the mechanical effect on the 3D human cochlea model and the behavior of electrode. Human cochlea is modeled by the spiral-approximation method and the shape of scala tympani is extracted from the mid section of the human cochlea. Contact pressure at the tip and the insertion force are found to be highest when the wires stack horizontally. Axial rotation of electrode is minimal comparing with the stimulating current spread. The results indicate that the electrode stiffness is important to minimize the trauma.

Prediction of transition in Czochralski process (초크랄스키 공정에서의 천이예측)

  • 최정일;성형진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.108-116
    • /
    • 1997
  • A laboratory experiment was made of critical transition flow modes in Czocllralski convection. Numerical computation was also made to delineate the dynamic transition. The period of temperature oscillation ($t_p$) and the interval of temperature oscillation ($\Delta\theta$) were scrutinized to capture the critical transition regime. The mixed convection parameter was varied in the range of $0.134\le Ra/PrRe^2 \le3.804$. The data from calculation were in good agreement with ones from experiment. The influence of the Prandtl number on the transition was examined for Pr = 910, 4445 and 8889. To understand the transition mechanism, the detailed temperature oscillation modes, the isolines of meridional temperature and the axial velocity profiles were investigated.

  • PDF