• Title/Summary/Keyword: 외벽

Search Result 484, Processing Time 0.024 seconds

A Study on the Performance Evaluation of Waterproof Sealant Materials for the Exterior Wall of PC Apartment House (PC 공동주택 외벽용 방수 실란트 자재의 성능 평가 연구)

  • Ko, Hyo-Jin;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.221-222
    • /
    • 2023
  • In this study, the performance evaluation of waterproof sealant materials applied to the outer wall of PC apartment houses was conducted. The sealant for PC members must have resistance to movement, and since it is exposed to outside air, weather resistance and water resistance are required.

  • PDF

Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 발코니 천정 내부결로 예측)

  • Choi Yoon-Ki;Ahn Jae-Bong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.155-163
    • /
    • 2003
  • There are a growing number of cases to expand balconies of apartments faced with open air in order to enhance functional satisfaction and efficiency of dwelling space. In case of the balcony expansion at the floor, however, it is difficult to exclude a possibility of bringing about internal condensation due to the difference of temperature between indoor air and outdoor air caused by the Inflow of outer low-temperature air through the upper part of ceilings by failure in completely putting together the outer composite wall panels on the aluminum curtain walls installed at outer walls This study is to forecast possible occurrence of internal condensation around parapets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation, which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature

Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires (구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석)

  • You, Woo Jun;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • In this study, the relations of the wall thermal conductivity and surface temperature in a compartment fire are investigated using Buckingham Pi theorem. The dimensionless parameters of the previous study are analyzed in order to correlate the dimensionless groups of the heat release rate, the thermal conductivity, the volume of compartment and the convective heat transfer coefficient. In addition the reduced scale of compartment, which has 1/6 size of ISO 9705 Room Corner Tester, is manufactured and the oxygen concentration and the maximum temperature in the space are measured for the gasoline pool fire ($10cm{\times}10cm$, $15cm{\times}15cm$ and $20cm{\times}20cm$). Finally, the criterion of the wall temperature increase are suggested in accordance with the thermal conductivity and the convective heat transfer coefficient. In addition, the dimensionless empirical equation using Buckingham Pi theorem considering the heat release rate are presented suggested. The results of this study will be useful especially for the fire phenomenon investigation of the wall thermal conductivity coefficient and shape in the compartment space.

A Study of Automatic Cleaning Tool Design for Façade in High-rise Buildings (고층 건물 외벽 청소용 자동화 기구 기안에 대한 연구)

  • Lee, Jin-Koo;Lee, Dong-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.56-63
    • /
    • 2012
  • Due to the development of construction technology, there is a considerable increase in the number of skyscrapers in the world. Accordingly, there are rapid growing requests about maintenance systems such as cleaning, painting, and monitoring the processes of facade in highrise buildings. However, it is extremely dangerous working the walls of high-rise buildings, and crashes from buildings have accounted for large proportion of constructional accidents. An alternative solution must be developed with the commercialization of automatic robot systems. For the last decade, interest in developing robots for cleaning and maintenance in facade of highrise buildings has continuously increased. The use of automatic robot systems can be expected to reduce accidents and decrease labor costs. In this paper, we propose a new kind of cleaning mechanism. We have designed and manufactured various cleaning tools for different types of facades with economic commercialization. The cleaning cycle, size, and intensity will be determined by economic constraints as well. The final goals are to design and manufacture tools and robots that can clean facades efficiently and rapidly even in dangerous places. The cleaning tool systems consist of nozzles, brush rollers, and squeezing devices. Furthermore, these tools and robots perform each process utilizing the systems of built-in guide types and gondola types for building maintenance. The performance of the proposed cleaning tools is evaluated experimentally; however additional study should be necessary for safer and more stable commercialization.

Analysis on Characteristics of Defects before Inspection for Apartment Use (공동주택 사용검사 전 하자 특성 분석)

  • Lee, Sang-Hyo;Han, Man-Cheon;Kim, Jae-Jun;Lee, Jeong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.167-178
    • /
    • 2020
  • The purpose of this paper is to establish a defect classification system for defects before inspection and to derive the pattern and characteristics of defects before inspection by examining about 3,110 defect items for 133 apartment buildings. The study analysis revealed a relatively high rate of defects before inspection that occurred in finishing work. Second, defects occurred such as cracking of external wall, which is a very important defect. However, defects before inspection were relatively rare on the external wall. Finally, defects before inspection occurred during waterproofing in the common area or garage. It is necessary to establish a reasonable basis or countermeasure to resolve differences between stakeholders as various issues may arise in the course of a dispute, as a result of identifying the details of defects within the top 20 of the defectives.

Effects of Soil Conditions on the Behavior of Open -Ended Steel Pipe Pile (지반조건의 변화가 개단강관말뚝의 거동에 미치는 영향)

  • Baek, Gyu-Ho;Lee, Jong-Seop;Lee, Seung-Rae
    • Geotechnical Engineering
    • /
    • v.9 no.3
    • /
    • pp.23-34
    • /
    • 1993
  • Model pile teats, using large calibration chamber in which the stress state and the relative density can be controlled, were performed in order to study on the effect of soil condition on the behavior of open-ended steel pipe pile. The model pipe pile was made up of two pipes to separately measure each component of bearing capacity of open -ended steel pipe pile. According to the tests results, pile plugging and driving resistance of the pile installed in sand were primarily dependent on the horizontal stress and the relative density. Plug bearing capacity, outside skin fricition and total bearing capacity were also mainly dependent on the horizontal stress and relative density. Moreover, the ratio of the horizontal stress acting on the outside wall of open -ended pipe pile after installation to the original horizontal stress was not nearly affected by original value of horizontal stress. It is bigger than one in the case of dense deposit, equal to one for medium deposit, and smaller than one for very loose deposit. It seems to be mainly dependent on the relative density for a given soil.

  • PDF

Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside (내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가)

  • Lee, Ju-Yeob;Song, Min-Jeong;Lee, Tai-Gang;Kim, Sun-Woo;Cheon, Deuk-Youm
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

The Effect on the Film Cooling Performance of Thrust Chamber with Combustion Performance Parameters (연소성능 파라미터가 추력실의 막냉각 성능에 미치는 영향)

  • Kim Sun-Jin;Jeong Chung-Yon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.4
    • /
    • pp.48-54
    • /
    • 2005
  • An experimental study was carried out to investigate the effect of film cooling in the lab-scale liquid rocket engine using liquid oxygen(LOx) and Jet A-1(Jet engine fuel) as propellants. Film coolants(Jet A-1 and water) was injected through the film cooling injector. The outside wall temperature of the combustor and film cooled length were determined for chamber pressure, mixture ratio, and the different geometries(injection angle) with the percent film coolant flow rate. The loss of characteristic velocity was determined for the case of film cooling with water and Jet A-1. As chamber pressure increased, the outside wall temperature increased in the nozzle but unchanged over the 9 percent film coolant flow rate for the combustion chamber used in this study. Characteristic velocity wasn't affected with the mixture ratio over the 9 percent film coolant flow rate.

A Study on the Mock-up test for applying BIPV in the external curtain Wall (수직 외벽면 적용 BIPV의 Mock-up 실험연구)

  • Lee, Han-Myoung;Oh, Min-Suk;Kim, Hway-Suh
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.110-118
    • /
    • 2009
  • This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard($950\;{\times}\;980mm$) large($950\;{\times}\;1960mm$)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1 W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.

CFD Based Shape Design of Guide Vane for Fan Filter Unit (전산유체해석을 이용한 Fan Filter Unit(FFU)의 가이드 베인 형상설계)

  • Jang, Jun Hwan;Ahn, Joon;Myong, Hyon Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.709-716
    • /
    • 2013
  • A fan filter unit (FFU) is a device which supplies clean air from the ceiling in a clean room. With an increase in its size, velocity variation occurs within the exhaust plane and this damage the product quality or productivity. Hence, a guide vane is installed inside the device to enhance the velocity uniformity. Because the vane reduces the flow rate for a given pumping power, an optimum design is required to achieve velocity uniformity while minimizing the flow rate reduction at the same time. To find a geometry that satisfies these requirements, a series of numerical simulations has been conducted while changing the angle and length of the guide vanes. By changing the geometry of the side guide vane, the velocity uniformity increased by 3.7% and the flow rate decreased by 1.5%. For the center guide vane, the velocity uniformity increased by 2.9% and the flow rate decreased by 0.7%.