The Changes of Conductor Temperature by Current and Environment Component of Wind Velocity and Ambient Temperature (환경 인자(풍속, 외기온도)와 전류량이 전선온도에 미치는 영향)

  • Kim, Shang-Shu;Kim, Byung-Geol;Jang, Tae-In;Kang, Ji-Won;Lee, Dong-Il;Min, Byung-Uk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.631-632
    • /
    • 2005
  • 대부분의 고압송전선은 알루미늄도체와 강심코어로 구성된 ACSR(Aluminum Conductor Steel Reinforced) 계통으로 건설되었다. 강심코어는 고탄소강으로 전선의 하중을 담당하며 알루미늄은 도체로 사용되고 있다. ACSR $410mm^2$ 가공송전의 온도와 전류량, 외기조건(온도, 풍속, 풍향각)과의 관계를 규명하는 것은 송전용량과 승전효율을 증진하는데 필수적이다. 전선온도는 전류량에 따라 직선적으로 변화하며 풍속 0.5 m/s와 태양열의 흡수가 없다고 가정하면 "전선온도($^{\circ}C$) = -0.3143 + 0.077$\times$전류랑(A)"의 관계를 가진다. 전류랑 852A에서 풍속에 따라 전선의 표면부와 강심부의 망사온도차는 감소하였다. 풍속 20m/s에서의 방사온도차는 약 $1.4^{\circ}C$로 나타났다.

  • PDF

Actual operation characteristics to evaluate the performance of heat pump outdoor unit in the constant temperature chamber (항온챔버에서 히트펌프 실외기의 성능을 평가하는 실제 운전)

  • Jong-Ryeol Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.123-128
    • /
    • 2022
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. In order to conduct a study that does not cause frost on the outdoor unit of the heat pump regardless of the season, a constant temperature chamber like a general room that can be tested under the same conditions as in the natural state was built. The experiment was conducted by providing an environment similar to the natural state to the outdoor unit of the heat pump installed in the constant temperature chamber. As a result, the lower the outdoor temperature, the lower the efficiency of the heat pump. It wat confirmed that the lower the value, the longer it is.

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement (분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구)

  • Kwak, Hyo-Gyoung;Ha, Soo-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.795-808
    • /
    • 2006
  • In this paper, an analytical method which can predict the occurrence of plastic shrinkage cracking on concrete slabs with sequential placement is proposed on the basis of the numerical model introduced in the previous study. The influence of many design variables on plastic shrinkage cracking such as the number of layers and the time interval between layers is quantitatively analyzed through parametric studies using the analytical method. In advance, two equations are introduced to take into account the effect of sequential placement on the plastic shrinkage cracking of concrete slab; The first one is to calculate the time at which the surface of concrete slab begins to dry, and the second one is to determine the critical time interval to prevent the surface drying of previously placed concrete layers. The timing of curing and the sequence of concrete placement, which are important for the prevention of plastic shrinkage cracking, can be effectively planned using the introduced both equations without any rigorous analysis.

Analysis of Internal Temperature Change according to the Application of Thermal Insulation Paint and Heat Pump in Broilers (육계사의 차열 페인트 및 히트펌프 적용에 따른 내부 기온 변화 분석)

  • Jun-Seop Mun;Rack-Woo Kim;Seung-Hun Lee;Sang Min Lee;Sang Kyu Choi
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • Heat stress causes a decrease in immunity and disease occurrence in livestock, increasing mortality and impairing productivity. In particular, chickens are very vulnerable to high temperatures compared to other livestock species because their entire body is covered with feathers and sweat glands are not developed. Currently, air conditioning systems are essential in broiler houses to prevent high-air temperature damage to broilers, but conventional cooling facilities are greatly affected by the external environment, so there are limits to their use. In this study, to propose a cooling method, thermal insulation paint and a heat pump were apply in the broiler houses to evaluate the temperature reduction effect. The heat pump experiment was to analyze the cooling effect according to the change in ventilation rate and propose an appropriate. As a result of the experiment, the heat-insulating paint reduced the temperature of the broiler houses by maximum 1-2℃, and in the broiler houses where the heat pump was operated, the temperature decrease was the largest when the ventilation rate was the lowest. When the air temperature in the house is similar to or lower than the outside air temperature, it is considered to be most effective to use a heat pump while maintaining only the minimum ventilation rate.

Air-side Heat Transfer and Pressure Drop of a Fin-and-Tube Heat Exchanger Under Low Temperature Condition (저온 조건에서 핀-관 열교환기의 공기측 열전달 및 압력손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.15-20
    • /
    • 2017
  • Currently, residential air conditioners operate as a heat pump during winter. In this case, the outdoor heat exchanger acts as an evaporator obtaining heat from cold air. On the other hand, it acts as a condenser during summer transferring heat to hot air. The outdoor temperature changes significantly from high to low. Generally, the air-side j and f factors are obtained at a standard outdoor temperature. Therefore, the applicability of the j and f factors under different outdoor conditions needs to be checked. In this study, tests were conducted for a two-row louver finned heat exchanger changing the outdoor temperature to subzero. The effects of the tube-side brine flow rate were also checked. The results showed that air-side j and f factors were essentially constant and independent of the outdoor temperature, suggesting that an extension of j and f factors obtained under standard conditions to a low outdoor temperature is acceptable. All j and f factors agreed within 9% and 3%, respectively. Tests were also conducted by changing the coolant flow rate. Both the j and f factors did not change according to the flow rate, suggesting that the tube-side heat transfer correlation is acceptable.

A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea (국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • In this study, a simulation program has been developed to predict the performance of energy recovery ventilators fur various indoor and outdoor conditions. In order to get a fundamental data about domestic air condition, the heat recovery ventilator is selected with the product of the wind quantity $250m^3/h$ Japanese M companies which are satisfied at High Efficiency Certification Standards. At the case on which the heat recovery ventilator is established, heating load decreases by 69.1% and cooling load decreases by 59.4% in Seoul, and heating load decreases by 66.4% and cooling load decreases by 59.6% in Pusan. The maximum humidification load of winter or summer time with $0.737{\ell}/h$ or $1.008{\ell}/h$ occurred in March from Kangnung or August from Mokpo respectively. In Southern part region and East Sea of winter time, the condensation or frost on exhaust side dose not occurred on exhaust side, but the area of that outside is occurred. Therefore, the preventive measure from the area except a southern part region and the east coast area must be considered, in order to condense or frost not to occur on exhaustion side in winter.

Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions (운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성)

  • Baek, Seung-Moon;Son, Chang-Hyo;Heo, Jeong-Ho;Choi, In-Soo;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1021-1026
    • /
    • 2014
  • In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet.

A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea (연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 -)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.241-245
    • /
    • 2009
  • Because of the heat island phenomenon and sea wind, there can be thermal conditions' differences around buildings at downtown and coastal area respectively in coastal city, like Busan, Incheon, Mokpo. For the final purpose of the buildings' energy saving design and operation considering of above mentioned environments differences, energy consumption including heating and cooling loads, electric loads are necessary to be accumulated and analyzed in as the database. As a part of this concept, this study aims to survey and analyze each loads of 22 apartments which has at least 100 households respectively and is located at Yeongdo island, Busan, Korea It is cleared that despite the residents living in this district can use sea wind as a natural ventilation and/or cooling methods, they mainly depends on the electric-driven air-conditioners for cooling with window-closed because of anti-salt problems of the sea wind. This leads the maximum power consumption of the surveyed-22-apartments to be appeared in August like that of inland buildings.

Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions (외기조건에 따른 제습냉방시스템의 성능 특성)

  • Lee, Dae-Young;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.