• Title/Summary/Keyword: 완화된 배근상세

Search Result 4, Processing Time 0.017 seconds

Seismic Evaluation of RC Special Shear Wall with Improved Reinforcement Details in Boundary Elements (경계요소의 횡보강근 상세를 개선한 RC 특수전단벽의 내진성능 평가)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • This paper summarizes the seismic performance of two shear walls with different reinforcement details in boundary elements. One is a special shear wall designed by KBC2009 and the other is a shear wall with improved reinforcement details in boundary elements, which is a newly proposed type of special shear wall. Experimental tests under cyclic reversed loading were carried out with two 2/3 scale shear walls which were modelled from the lower part of seismic-resisting shear wall in 22-stories wall-slab apartment building. The experimental results show that seismic performance of shear wall with improved reinforcement details was almost similar to that of special shear wall with respect to the moment-drift ratio. However, energy dissipation capacity and ductility were slightly different. Also, shear wall with improved reinforcement details in boundary elements satisfied the inter-story drift limit of 1.5% from KBC2009.

Seismic Performance of Special Shear Wall with the Different Hoop Reinforcement Detail and Spacing in the Boundary Element (경계요소 횡보강근의 상세와 배근간격에 따른 특수전단벽의 내진성능)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.6 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • This paper presents experimental results on detailing of boundary element transverse reinforcement, proposed to alleviate placement detailing of special shear wall experiencing difficulty in construction at the sites due to recently reinforced seismic regulations, according to the type and placement interval of transverse reinforcement. As a result of experiment, crack and destruction aspects of SSWR series specimen that employed the proposed detailing of transverse reinforcement showed similar trend as SSW series specimen that used closed hoop. Predicted maximum strength values were exceeded. Also as a result of comparing energy dissipation ability, SSWR2 specimen that follows alleviated placement detailing was found to have similar seismic performance as special shear wall SSW2 specimen based on the existing design standard. As it satisfies the deformation angle condition of 1.5% provided in the design standard, SSWR2 can be used as the main lateral force resistance element in structures.

Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail (완화된 단부 배근상세를 갖는 특수전단벽 구조시스템의 내진성능평가)

  • Chun, Young-Soo;Lee, Ki-Hak;Lee, Hyo-Won;Park, Young-Eun;Song, Jin-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.271-281
    • /
    • 2013
  • The current seismic design code prescribes that a structural wall should be designed as a special shear wall when the building height is more than 60 m and its seismic design category is classified as D. However, the use of a special shear wall has a negative effect on constructability and economic efficiency. In the present study, the seismic performance of a special shear wall and a special shear wall with relaxed reinforcement detail was evaluated through a cyclic reversal loading test. The specimens were constructed to measure the results of the experimental variable regarding the reinforcement details of the special boundary element. Next, the seismic performances of a special shear wall structural system and that of a special shear wall structural system with relaxed reinforcement detail was evaluated by methods proposed in the FEMA P695. The cyclic reversal loading test results of this study showed that the performance of the shear wall with relaxed reinforcement detail was almost similar to the performance of a special shear wall and has the performance which requested from standard. The results of the seismic evaluation showed that all special shear walls with relaxed reinforcement detail are satisfied with the design code and seismic performance.

Seismic Performance of Coupled Shear Wall Structural System with Relaxed Reinforcement Details (완화된 배근 상세를 갖는 병렬전단벽 구조시스템의 내진성능평가)

  • Song, Jeong-Weon;Chun, Young-Soo;Song, Jin-Kyu;Seo, Soo-Yeon;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.187-196
    • /
    • 2016
  • The current seismic design code prescribes that coupling beam should be reinforced using diagonally bundled bars. However, the use of a diagonally bundled bars has a negative effect on constructability and economic efficiency. In the present study, the seismic performance of 4 coupling beams with the different details of reinforcement was evaluated through a cyclic reversal loading test. The specimens were constructed to measure the results of the experimental variable regarding the details of shear reinforcement. Next, the seismic performance of the coupled shear wall system evaluated by methods proposed in the FEMA P695. The cyclic reversal loading test results of this study showed that the performance of coupling beams with relaxed reinforcement detail was almost similar to that of a coupling beam with the ACI detail and meet the level which requested from standard. The result of the seismic evaluation showed that all coupling beams are satisfied with the design code and seismic performance.