• Title/Summary/Keyword: 와류발생기

Search Result 112, Processing Time 0.023 seconds

Numerical Investigation of the Combustion Instability inside a Partially Premixed Combustor according to Fuel Composition (연료 조성에 따른 부분예혼합 연소기 내부 연소불안정 해석)

  • Nam, Jaehyun;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.2
    • /
    • pp.24-33
    • /
    • 2021
  • Numerical study is conducted to analyze combustion instability in the partially premixed combustor. The simulations are performed according to fuel conditions, and Large Eddy Simulation(LES) model and PaSR combustion model are implemented in the solver. Comparison with the experimental result is conducted to confirm the validity of simulation, and quantitative and qualitative agreement is confirmed. The flame characteristics in the combustor are subsequently investigated, and the association with the occurrence of combustion instability is clarified. According to the simulation results, the flame length varies greatly depending on the fuel conditions. When the flame length becomes sufficiently long, flame-vortex interactions occurred around the wall sections, which works as the main cause of combustion instability.

NUMERICAL ANALYSIS OF THE GUST GENERATOR FOR KARI LOW SPEED WIND TUNNEL (KARI 중형 아음속 풍동용 돌풍 발생기의 수치해석)

  • Park Y. M.;Kwon K. J.;Lee S. W.;Kim T. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.275-279
    • /
    • 2005
  • The vortex convection and induced flow field behind the KARI 3m x 4m LSWT gust generator was computed by using Computational Fluid Dynamics. For the accurate simulation of vortex convection, inviscid, laminar, Spalart-Allmars k-e and k-w turbulence models were tested with the NAL gust generator configuration and Spalart-Allmaras turbulence model was selected for the prediction of induced flow field behind the KARI LSWT gust generator. The wind tunnel test was also carried out at KARI LSWT and the results were compared with CFD prediction.

  • PDF

Two-Dimensional Hydraulic and Numerical Modeling of tidal Currents in Chinhae Bay (鎭海灣 潮流의 2차월 水利 및 數値 모델링)

  • 김차겸;장선덕
    • 한국해양학회지
    • /
    • v.29 no.2
    • /
    • pp.83-94
    • /
    • 1994
  • Two-dimensional tidal and tidal residual currents in Chinhae Bay are investigated by field observations, hydraulic and numerical experiments. The results of hydraulic and numerical model experiments roughly coincide with the field measurements. Maximum tidal currents during the spring and neap tides in Kaduk and Kyunnaeryang channel and the central channel of Chinhae Bay are strong as 90 to 110 and 30 to 40 cm/s respectively, and strong tidal residual currents having numerous eddies take place. Maximum tidal currents during the spring and neap tides in the western and northern parts of the bay are weak as below 30 and 10 cm/s respectively, and also tidal residual currents are relatively weak. Tidal residual currents in the northern part of Kajo-do go toward the north, whereas the currents in the southern part move down the bay, and the currents rotating clockwise occur around Bu-do. The surface currents in the bay depend strongly on the wind and river inflow, and such phenomena are more remarkable during he neap tide than the spring tide.

  • PDF

Experimental Study on Combustion Instability in a Dump Combustor (덤프 연소기에서의 연소불안정에 대한 실험적 연구)

  • An, Gyu-Bok;Yun, Yeong-Bin;Yu, Kenneth
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.35-40
    • /
    • 2006
  • The combustion instability in a model dump combustor with an exhaust nozzle and the possibility of combustion control using a loudspeaker to these instabilities were studied. By changing inlet velocity, combustor length and equivalence ratio, dynamic pressure signals and flame structures were simultaneously taken. Because inlet velocity and combustor length affect the life time of vortex in the dump combustor, the results showed that as the combustor length increased and the inlet velocity decreased, the instability frequency decreased and the maximum power spectral density of the dynamic pressure generally decreased. Also, instability frequency and maximum power spectral density of the dynamic pressure increased with the increment of equivalence ratio. From the data of close-loop control, the optimum time-delay control using a loudspeaker was confirmed to be able to reduce the vortex shedding induced from the mixed acoustic-convective mode combustion instability.

A Study on Heat Release Fluctuation Using Various Hydrocarbon Fuels (다양한 탄화수소 연료를 이용한 열방출 섭동 연구)

  • Hwang, Donghyun;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.6
    • /
    • pp.1-10
    • /
    • 2016
  • For the active control of a combustion instability, a change should be made in pressure fluctuation or heat release fluctuation using an acoustic driver or a secondary fuel injection. Also, to determine the location and timing of a secondary fuel injection, one needs to know the distribution of heat release fluctuation under combustion instability. In the present research, the distribution of heat release fluctuation has been experimentally measured by changing hydrocarbon fuel, inlet velocity, equivalence ratio, and acoustic forcing condition. It was confirmed that heat release fluctuation with regards to vortex shedding was significantly affected by the $Damk{\ddot{o}}hler$ number. Under the cases of the $Damk{\ddot{o}}hler$ number above approximately 4 - 5, hot spot region was generated in the leading edge of vortex and cold spot region was in the trailing edge. On the contrary, the cases of the $Damk{\ddot{o}}hler$ number below 3 showed the opposite trend.

A study on prediction of propellant distribution of single swirl coaxial injector in gas generator (가스발생기용 단일 스월 동축형 분사기의 추진제 분포 예측에 관한 기법 연구)

  • Kim Jong-Gyu;Kim In-Tae;Han Yeoung-Min;Seol Woo-Seok;Lee Kwang-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.205-209
    • /
    • 2004
  • The configuration and arrangement of injector in LRE gas generator and combustor have a great impact on combustion process and heat exchange because of affecting atomization, vaporization, mixing and chemical reaction. A relation between injector array and mixing distribution of propellants based on a physical approach was investigated in this study. Programming method of this relation is used to predict mixing distribution of propellants. Simplicity of physical approach and various assumptions make it reduce the accuracy and application of the results of present study. But, this method is very useful to predict the mixing distribution of full scale combustor due to difficulties in cold flow testing.

  • PDF

Numerical investigation into cavitation flow noise of hydrofoil using quadrupole-corrected Ffowcs Williams and Hawkings equation (사중극자 보정 Ffowcs Williams and Hawkings 방정식을 이용한 수중 익형 공동 유동소음에 대한 수치적 고찰)

  • Ku, Garam;Ryu, Seo-Yoon;Cheong, Cheolung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.263-270
    • /
    • 2018
  • In most industry fields concerning external flow noise problems, the hybrid computational aeroacoustic techniques based on the FW-H (Ffowcs Williams and Hawkings) equation are widely used for its numerical efficiency. However, when the surface integral form of FW-H equation is used without volume quadrupole sources, it is known to generate significant non-physical noise in a certain case. Especially, in the case of a flow in which the tip vortex cavitation is formed in the distant downstream direction such as flow driven by an underwater propeller, the accuracy in noise prediction becomes poor unless it is not properly modelled. Therefore, in this study, the nonphysical acoustic waves caused by the surface integral form of FW-H equation is reduced by adding the quadrupole correction term. First, to verify the accuracy of the in-house code of FW-H equation, the noise by an axial fan used in the outdoor unit of air conditioner was calculated and compared with the results of ANSYS Fluent. In order to verify the effects of the quadrupole correction term, the noise prediction for isentropic vortex convection is performed and it is confirmed that the error is reduced by the quadrupole correction term. Finally, the noise prediction is performed for the flow field generated by the Clark-Y hydrofoil in underwater. It is confirmed that the error caused by the cavitation passing through the integral surface can be reduced by the quadrupole correction term.

An Experimental Study on Transient Heat Transfer Characteristics of Gas Turbine Cooled Vane by Using Liquid Crystal Thermography (가스터빈 냉각 베인에서 감온액정을 이용한 과도적 열전달 특성에 관한 실험적 연구)

  • Suh Nam-Kyu;Chang Tae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.22-29
    • /
    • 2006
  • Gas turbine engine among Principal internal combustion engines has been mainly applied as an aero and industrial Power plant. In order to increase its thermal efficiency. it has been raised their pressure ratio of compressor and the turbine inlet temperature. To operate above the limit temperature of turbine material, turbine nozzle vanes should be cooled. For this the cooling air is bled from the compressor section of 9as turbine. Meanwhile, to keep high thermal efficiency of 9as turbine, turbine vanes are to be cooled by using small cooling air Therefore, the complex cooling passages are requested to be designed and evaluated the effectiveness of vane cooling by measuring turbine vane temperature. But it is very difficult or impossible for us to measure local turbine temperatures at actual temperature When local heat transfer coefficients are known these can be calculated, therefore this study has been investigated on obtaining these coefficients of turbine vane at room temperature using TLC.

Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime (레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가)

  • Kwak Kyung-Min;Song Gil-Dal
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

An Experimental Study on the Local and Overall Heat Transfer Characteristics of a Fin-Flat Tube Heat Exchanger (납작관형 핀-관 열교환기의 국소 및 총합 열전달 특성에 관한 실험적 연구)

  • 유성연;정민호;박동성;이상섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.939-947
    • /
    • 2002
  • Local and overall heat transfer characteristics of fin-flat tube heat exchangers with and without vortex generators are investigated. Local heat transfer coefficients are measured with the heat exchanger model using naphthalene sublimation technique. In case of a fin-flat tube heat exchanger without vortex generators, only the horseshoe vortices formed around tubes augment the heat transfer. On the other hand, longitudinal vortices created artificially by vortex generators enhance heat transfer dramatically in case of a fin-flat tube heat exchanger with vortex generators. Overall heat transfer coefficients are measured with the prototype of the fin-flat tube heat exchanger with and without vortex generators in a wind tunnel and results are compared with those of a fin-circular tube heat exchanger with wavy fin. Friction losses for heat exchangers are also measured and compared. The fin-flat tube heat exchanger with vortex generators is found to be more effective than the fin-circular tube heat exchanger with wavy fin.