• Title/Summary/Keyword: 와강도

Search Result 2,624, Processing Time 0.034 seconds

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.

Experimental Study on the Properties of Strength of the No-Fines Concrete (No-Fines Concrete의 강도특성(强度特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Seong Wan;Sung, Chan Yong;Min, Jeong Kie
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.2
    • /
    • pp.373-383
    • /
    • 1987
  • No-fines concrete is concrete from which the fine aggregate fraction has been omitted. The concrete so formed, consisting only of coarse aggregate, cement, and water, has large voids uniformly distributed through its mass. This study was performed to obtain the basic data which can be applied to the use of no-fines concrete. The data was based on the properties of no-fines concrete depending upon various mixing ratios. The results obtained were summarized as follows. 1. Test result of the consistency, suitable water-cement ratio was increased with the increasing of mixing ratio. 2. At the suitable water-cement ratio, the highest strengths were showed. But it gradually was decreased with the increasing of mixing ratio and strengths are considerably lower than that of conventional portland cement concrete. 3. The relations between compressive and tensile strength were highly singnificant as a straight line shaped. The strength ratio was decreased with the increasing of mixing ratio and considerably lower than of conventional portland cement concrete. 4. Bulk density was decreased with the increasing of the mixing ratio, and was similar to that of the conventional portland cement concrete at mixing ratio 1:4. 5. The relations between strength and bulk density were highly significant as a straight line shaped. The decreasing ratio of strengths was higher than that of bulk density.

  • PDF

Fracture Behavior of Advanced Composite Material (첨단복합소재의 파괴거동)

  • 김윤해;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.52-62
    • /
    • 1994
  • 기계나 구조물 파괴의 대부분은 노치부를 기점으로 하여 발생하기 때문에 첨단복합재료를 노지부 재로서 안전하면서도 경제적으로 사용하기 위해서는 각종 조건하에 있어서 강도특성을 명확히 하는 것은 대단히 중요하다. 본 연구에서는 노치를 갖는 복합재료를 이용하여 각종조건하에서 강도특성평가실험을 행하였으 며, 얻어진 결과를 종합하면 다음과 같다. (1) 첨단복합재료 노치재는 試驗片의 幾可學的 形狀과는 관계없이 노치반경 p만에 의해 결정되는 최대탄성응력 $\sigma_{max}$일정의 條件下에서 破t짧된다. (2) 破斷時 최소단면에서의 공칭응력 $\sigma_{c}$와 응력집중계수 $K_{t}$와의 관계에 있어서,$\sigma_{c}$의 값이 $K_{t}$의 증대와 더불어 떨어지고 있는 부분과, $K_{t}$와 관계없이 거의 일정하게 되고 있는 부분으로 나누어지는 現象은 노치재의 回轉굽힘 또는 인장압축파열에서 보여지는 현상과 外觀上 對應하고 있다. 즉, 정적파괴와 피로파괴는 파괴의 양상이 비슷하다 (3) PEN수지단체의 경우, 피로균열발생은 점발생적 피로균열이 최대탄성응력에 의해 지배되며, 노치에 만감하며,균열전파수명은전수명에 비해 상당히 짧다. (4) 단탄소섬유강화복합재료의 경우, 피로균열은 섬유端에 응력이 집중하기 때문에 일반적으로 섬유端에서 아주 빠른 시기에 발생하지만, 섬유가 피로균열진전에 대해 방해물로 작용하기때문에 아주 천천히 전파한다. (5) 短탄소鐵維는 피로균열발생에 대해서는 負의 강화작용 전수명의 극히 초기단계에 피로균열 발생을, 피로균열전파에 대해서는 正의 강화작용을 한다. (6) 단탄소섬유를 PEN에 강화함으로 인해 정적강도 보다 피로강도에 더 큰 강화효과를 초래했으며, 선형노치역학의 개녀은 첨단 복합재료의 강도평가에 대단히 유효했다.

  • PDF

Prediction of rainfall-induced runoff considering infiltration of water in both unsaturated and saturated porous media (불포화 및 포화 투수층에서의 침투를 고려하여 강우 유출 해석)

  • Changhoon Lee;Minh Thang Tran
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.62-62
    • /
    • 2023
  • 강우가 지표면 아래로 침투할 때 초기에는 투수층이 불포화 상태이어서 부압이 작용하면서 침투할 것이다. Richards 식(Richards, 1931)을 써서 불포화 투수층의 침투를 모의할 수 있다. 강우가 지속되는 동안 하상 아래 어느 구간은 포화 상태가 되어 Richards 식을 더 이상 사용할 수 없다. 하지만 현재까지의 연구는 Richards 식을 사용하여 침투를 모의하는 오류를 범하고 있다. 강우에 의한 침투를 예측할 때 지표면에서의 침투율 qb 가 필요한 데 현존하는 연구에서는 Horton 식(Horton, 1941)을 사용하여 초기 침투율 fo 와 장시간 후 침투율 fc 와 시간에 따라 지수함수로 감소하는 계수 k 의 3가지 계수값을 실험이나 현장 관측값에서 찾아서 쓰고 있다. 그런데, 이 계수값은 강우강도 ri 가 클수록 침투율 q 가 커지는 물리 현상을 반영하지 못하는 한계가 있다. 본 연구에서 먼저 포화 투수층에서의 침투를 모의하는 식을 개발하였다. 지표면 아래에서 불포화 투수층에는 Richards식을 사용하고 포화 투수층에는 개발한 식을 사용하여 침투를 모의하였다. 또한 지표면에서의 침투율 qb 를 구하는 공식을 개발하였다. 하상에서의 침투율의 최대값은 $q_{bmax}=-{\lambda}{\sqrt{2g(s-b)}}$ 일 것이다. 여기서 λ 는 투수층의 공극율, s 는 유출수면의 위치, b 는 지표면의 위치이다. 지표면에서의 침투율의 최소값 qbmin 은 지표면 바로 아래 지점에서의 침투율일 것이다. 지표면에서의 침투율 qb 로 qbmax 와 qbmin 사이의 적절한 값을 선택한다. 강우강도를 ri 라고 하면 지표면 위 유출수의 연속방정식은 다음과 같다: $s-b={\int}(r_i-{\mid}q_b{\mid})dt$. 즉, 유출수면의 위치 s 는 강우강도 ri 가 클수록 또는 지표면에서의 유출율의 크기 |qb| 가 작을수록 크다. 또한 지표면에서의 침투율 qb 와 지표면 아래에서의 침투율 q 는 s - b 가 클수록 크다. 따라서, 강우강도 ri 가 클수록 침투율 qb, q 가 큰 현상이 잘 반영되었다. 강우-침투-유출 모형실험을 수행하여 강우강도에 따라 침투율과 유출량이 다른 현상을 관측하여 수치실험 결과와 비교·검증하였다.

  • PDF

Response of Bridge Piers Retrofitted by Stainless Steel Wire under Simulated Seismic Loading (내진 모사하중에 의한 스테인레스강 와이어 보강 교각의 응답)

  • Choi, Jun Hyeok;Kim, Sung Hoon;Lee, Do Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.343-350
    • /
    • 2009
  • In the present study, a new seismic retrofitting method that employs both a stainless steel wire mesh and a permeable polymer concrete mortar was proposed for reinforced concrete bridge piers with nonseismic design details. For this purpose, a total of six nonseismically designed bridge piers were tested under lateral load reversals. The test results reveal that nonseismically designed piers with lap splices need to be retrofitted to resist earthquake induced forces. In addition, it was proven that the proposed retrofitting method can be useful in improving the strength, stiffness, and energy dissipation capacities of bridge piers designed nonseismically. It is thus expected that the proposed method may provide an improved ductility capacity without sudden softening of strength for bridge piers excursing inelastic displacement range.

An Experimental Study on Shear Capacity of High-Strength Concrete Beams With Shear Span-Depth Ratio Between 1.5 and 2.5 (전단-스팬비가 작은 고강도 철근콘크리트 보의 전단성능에 관한 실험적 연구)

  • 신성우;문정일;박희민;이승훈;오정근;임남재
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.4
    • /
    • pp.171-179
    • /
    • 1992
  • 본 연구에서는 전단-스팬비가 1.5에서 2.5 범위의 고강도 콘크리트 보에 대해 기존 규준식의 안전여부를 확인하고, 사균열강도와 극한전단강도를 결정하기 위해 총 15개의 시험체를 제작하여 실험적 연구를 수행하였다. 주요변수는 전단-스팬비(a/d=1.5, 2.0, 2,5)와 수직전단철근비(Rv=0, 25, 50, 75, 100%, Rv=[$ ho$v / $\rho$v(ACI)] 100)이며, 콘크리트 압축강도(f'c=747kg/$ extrm{cm}^2$와 인장철근비($\rho$w=0.0377)는 일정하다. 실험결과 본 연구의 전단-스팬비의 범위에서 ACI 318-89 (11-31)식은 일반적으로 수직전단철근에 의해 저항되는 전단강도를 상당히 과소평가하는 것으로 나타났다. 따라서 수직전단철근에 대한 영향이 재고되어야 할 것이다.

The effects of heat-treatment on the mechanical properties of the Cu-bearing HSLA steels (Cu를 함유한 저합금 고장력강의 기계적 성질에 미치는 열처리의 영향)

  • Park, Tae-Won;Sim, In-Ok;Kim, Yeong-U;Gang, Jeong-Yun
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.333-344
    • /
    • 1995
  • Cu를 함유한 2종의 저합금 고장력강(HSLA-A, HSLA-B)\ulcorner 기계적 성질에 미치는 시효처리의 영향을 조사하였다. 탄소량이 적음에도 불구하고 Cu첨가로 석출물을 생성시킴으로서 2합금 모두 $650^{\circ}C$에서 시효한 경우 양호한 강도(HSLA-A:Y.S 703Mpa, E.L 22.6% HSLA-B:Y.S 810 Mpa, E.L 23.8%)와 인성(HSLA-A:271.4J, HSLA-B:197.5J at -5$0^{\circ}C$)의 조합을 나타내었다. 50$0^{\circ}C$에서 시효할 때 가장 높은 항복 강도를 나타내나 인성은 아주 낮은 값을 나타내었다. 50$0^{\circ}C$이상 시효 온도가 증가하면 강도는 감소하고 인성은 증가하였다. HSLA-B강의 강도가 HSLA-A 강보다 높은데, \ulcorner칭 상태에서의 강도 차이는 경화능을 증가시키는 원소인 Ni, Mn, Mo, Cu의 첨가량 차이에 의한 기지 조직의 차이에 의한 것이며, 시효한 상태에서의 강도 차이는 기지 조직과 석출 강화에 기여하는 Cu량의 차이에 의한 것으로 판단된다. 시효 경화 곡선에서 $700^{\circ}C$에서의 경도 증가는 오스테나이트-페라이트 2상 영역으로부터 냉각시 생성된 “M-A constituents”에 의한 것이다. HSLA-A강과 HSLA-B강의 충격 천이 온도는 각각 -1$25^{\circ}C$와 -145$^{\circ}C$이었다.

  • PDF

A Study on Shear Strength of Granular Due to The Various Particle Size (조립질 입자크기가 전단강도에 미치는 영향)

  • Lee, Seungho;Seo, Hyungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2012
  • Shear strength of soil is power that resists failure and sliding according to any face in soils and one of the most important factors during engineering properties of soil. Shear strength is used for engineering science problems as bearing capacity methods of foundation or piles, slope stability after dam or Cutting Embankment and stability problem analysis of soils as lateral earth pressure of soil structures, ets. This study has analyzed shear strength change of samples classified 2.00mm(10sieve)와 0.85mm(20sieve), 0.475mm(40sieve) using direct shear tester after removing and drying cohesive soil ingredient of Weathered granite soil Therefore, this study would help studies about shear strength properties by particle size.

Effects of the Treated Chemicals on the Flexual and Physical Properties of Fire Retardant Treated Particleboards (내화처리(耐火處理) 파티클 보오드의 휨강도(强度)와 물리적(物理的) 성질(性質)에 미치는 약제(藥劑)의 영향(影響))

  • Lee, Phil-Woo;Kwon, Jin-Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.39-48
    • /
    • 1983
  • This research was performed to investigate the manufacturing possibility of the particleboard treated with commercial fire retardant chemicals. Laboratory test boards at this investigation were made from particles treated by soaking into 5, 10, 15, and 20 percent concentration solutions of ammonium sulfate and Minalith before resin was applied. According to the results, MOR (modulus of repture) and MOE (modulus of elasticity) in flexure exceeded type 100 (100 kgf/$cm^2$, $1.5{\times}10^4\;kgf/cm^2$) of the Korean Industrial Standard (KS F 3104). Except for 15 and 20 percent chemicals concentrations of Minalith, every internal bond stress values met type 100 (1.5 kgf/$cm^2$) of KS F 3104. However thickness swelling values of fire retardant treated particleboards were not reached in the Standard (12%).

  • PDF

An Analytical Study on the Ultimate Strength of Concrete Poles (콘크리트 전주의 극한강도에 관한 해석적 연구)

  • Shin, Dong-Geun;Yoon, Ki-Yong;Lee, Seung-Hyun;Yi, Gyu-Sei;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.19-25
    • /
    • 2007
  • In this study, a program based on the P-M interaction curve is developed to calculate the nominal strength of concrete pole. Using this, it is verified to compare with previous studies and the nominal strength$(M_n)$ of concrete pole is calculated. It is less than the rupture strength$(M_r)$ of the design standard. Thus, to increase nominal strength, several parameters are selected like as size of tension and reinforced bars, position of those, number of reinforcement bars, thickness of concrete pole, and diameter of it. The effects of those are analysed in the study. It is supposed that section of concrete pole are satisfied rupture strength.