• Title/Summary/Keyword: 온풍

Search Result 111, Processing Time 0.027 seconds

생천마 저장기간 연장 - 필름포장에 의한 밀봉저장법 효과적

  • 한국생약협회
    • The Hankook-Saengyark Bo
    • /
    • no.252
    • /
    • pp.5-5
    • /
    • 2002
  • 참당귀 노지육묘때 비가림시설 설치(점무늬병 발생줄고 규격묘 생산량은 증가) - '잔대' 꽃대 8월상순 제거 품질 좋아지고 증수 - 상황버섯 참나무 톱밥배지 사용(관행재배시 보다 수확량 두배 증수) - 농작물 온풍건조기 한약재 건조에 적합 -삼백초 7월말$\cdot$10월말 2번 나눠 수확

  • PDF

A Study on Application of Warm Air Circulator by Using the Carbon Heating Element with Particle Type (입상 탄소 발열체의 열원을 이용한 온풍기의 적용에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Kong, T.W.;Chung, H.S.;Jeong, H.Y.;Chung, H.T.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.31-37
    • /
    • 2003
  • This paper is a study on application of warm air circulator by using the carbon heating element with particle type. The main variables are the input current and amount of carbon heating source for experimental characteristics. The experimental results are obtained as follows. As the input current and temperature are increased, the resistance of heat source is decreased about $20{\sim}25%$ by the effect of negative resistance. As the amount of heating source is small, Joule heat is large with the input current. When the amount of heating source is 300 and the input current is 15A, the value of Joule heat is about 4604.6kJ/h. The heat production efficiency of carbon heating source is larger about 10% than the sheath heater.

  • PDF

Development of Power Supply Time Controller during Off-Peak Period for Thermal-storage Electric Heat Radiator (축열식 전기온풍기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon, Seong-Chul;Han, Seung-Ho;Ko, Kee-Joong;Chung, Woo-Yong;Lee, Hak-Ju;Na, ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2334-2336
    • /
    • 2002
  • 한전에서는 수요관리정책의 일환으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하여 전력공급 원가절감에 노력하여 왔으나, 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단신간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기의 하나인 축열식 전기온풍기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다.

  • PDF

플라즈마 제트의 혈액 응고 작용과 정량적인 측정 방법에 관한 연구

  • Kim, Yun-Jung;Lee, Won-Yeong;No, Jun-Hyeong;Hyeon, Seong-Bo;Eo, Yun;Park, Jin-Yeong;Lee, Yong-Min;Kim, Hui-Ju;Gwon, Gi-Cheong;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.514-514
    • /
    • 2013
  • 플라즈마와 혈액의 상호작용 특성을 파악하기 위해 혈액응고 실험을 하였다. 생체에 적용 가능한 바이오 플라즈마 소스를 개발하여 다양한 조건으로 혈액에 플라즈마를 조사하였다. 혈액 응고의 정량적인 측정 방법으로 혈액의 저항을 측정하였다. 본 실험에 사용된 플라즈마 제트 장치는 의료용 바늘과 유리관, 외부 접지로 이루어져 있다. 플라즈마 제트 장치는 고전압 전극이 유리관 안에 위치하고 접지 전극이 유리관 바깥에 위치한다. 의료용 바늘을 통해 Ar gas를 주입하며, 약 2 kV의 전압을 인가하여 방전시켰다. 자연적으로 혈액을 응고시킨 경우, 칼슘 클로라이드를 첨가하여 응고시킨 경우, Ar gas 및 온풍을 단독적으로 불어넣은 경우, 그리고 플라즈마 제트를 조사한 경우로 나누어 실험을 진행하였다. 두개의 떨어진 전극 사이에 일정량의 혈액을 배치시켜 저항을 측정하여 응고 정도를 파악하였다. 플라즈마 제트를 조사하였을 경우 아무것도 처리하지 않은 자연상태의 혈액보다 혈액이 응고되는 속도가 빠르게 나타났다. Ar gas와 온풍을 단독으로 불어넣어 준 경우와 혈액 표면이 응고되었으나, 약 20초가 지나면 다시 원래 상태의 혈액으로 돌아감을 확인하였다. 플라즈마 제트를 혈액에 조사했을 때는 혈액이 이전의 혈액 상태로 돌아가는 경향이 나타나지 않았다.

  • PDF

Study of occurrence of cool air in summer and warm air in winter of Chonbuk Jinan Poonghyeol (전북 진안 풍혈의 여름철 냉풍 및 겨울철 온풍 발생 연구)

  • Kim, Young-Il;Shin, Young-Gy;Seo, Jeong-Ah;Choi, Yong-Don;Song, Tae-Ho;Kang, Chae-Dong;Kim, Seong-Sil;Rho, Jeong-Sun;Jeong, Si-Young;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.879-884
    • /
    • 2006
  • Jinan Poonghyeol in Chonbuk province Is famous for emitting cool air in summer and warm air in winter. Cause for these phenomena is studied by measuring temperature, humidity and air velocity of several locations around Jinan Poonghyeol Temperature variations under the ground are also measured. Analyzing data compiled from July 21, 2005 through May 26, 2006, it is presumed that storage effect of rocks and soil in this area and buoyance effect are the main causes for this mysterious natural air-conditioning phenomena.

  • PDF

Comparison of Thermal Environment in Single Span Plastic Greenhouses with an Electrical Heating, Hot-Air Heating nit without Heating (전기히터식 난방, 온풍난방 및 무가온 단동 플라스틱 하우스의 열환경 비교)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.125-135
    • /
    • 1999
  • In this paper, the thermal characteristics in plastic greenhouses with heating systems of electric power, hot air, and non-heating are measured and analyzed by field tests. From these tests, we were able to estimate the heating efficiency and quantitatively evaluate the characteristics of indoor thermal distributions of the particular heating system in greenhouses. The heating system of electric power was ineffective to reduce the difference of thermal distribution in the vertical direction. The hot air heating system also does not properly reduce the serious temperature fluctuation by time. By removing the above problems, these data will be utilized effectively to design better thermal environment in greenhouses.

  • PDF

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.