• Title/Summary/Keyword: 온열쾌적도

Search Result 151, Processing Time 0.025 seconds

A Study on Characteristics of Indoor Thermal Environment and Comfort Evaluation in Summer and Winter (하계 및 동계 실내 온열 환경 특성과 쾌적성 평가에 대한 연구)

  • 고경태;박종일;김경훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.88-93
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physical responses for men in summer and winter indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart rate(Electrocardiogram, ECG), Electroencephalo gram(EEG) were examined. We found that comfort of people was achieved at SET*. 24.7$^{\circ}C$, -0.82${\alpha}$-wave) both in summer and in winter.

  • PDF

Measurements of Temperature Distribution on Human Body Surface using Multi-Channel Skin Temperature Sensors (다채널 피부온 센서를 이용한 인체표면 온도분포의 측정)

  • 한화택;김민규;박명규;이성수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.205-209
    • /
    • 2002
  • 인체의 피부온도는 쾌적성과 감성에 크게 영향을 미치며 의류의 개발이나 건축환경의 설계 등에 활용되고 있다. 단순히 몇몇 측정점에서의 피부온도 데이터가 아니라 인체표면에 걸친 온도분포를 파악함으로써 다양한 정보를 이용하여 보다 광범위한 응용분야에 활용될 수 있을 것이다. 현재 인체표면의 온도분포를 측정하기 위하여 대부분 적외선 열화상 카메라를 활용하고 있다 그러나 열화상 카메라는 서미스터 등을 이용한 피부온 센서에 비하여 온도분해능이 떨어지며 특히 의복내의 피부온을 측정하는 것이 불가능하고 노출된 인체표면에 대해서만 측정이 가능하다. 따라서 본 연구에서는 피부온 센서를 이용한 인체표면 온도분포 측정시스템을 개발하기 위하여 각 센서의 위치와 간격, 그리고 인체 곡면을 따라서 보간법에 따라 온도분포 결과에 미치는 영향을 파악하고 적외선 화상 결과와 비교하고자 한다.

  • PDF

The Development of Multi-channel Temp & Humi Distribution Tester (다채널 온습도 측정기 개발)

  • 김성환;지용주;이성수;김태훈;김묘향;한화택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.211-215
    • /
    • 2001
  • 실내나 의복내 열적쾌적성을 평가하기 위해서는 정밀하고, 안정성이 높으며 빠른 응답특성을 갖는 센서와 측정시스템이 필요하다. 더욱이 의복내의 온도를 측정하기 위해서는 소형, 경량으로 인체에 부착하기 쉬워야하며 측정기의 부착이 피험자에게 부담을 주어서는 안된다. 본 연구에서는 이러한 요구사항을 만족할 수 있으면서도 이동이 자유롭고 장시간 측정이 가능한 큰 Data 저장용량, 실시간 측정 기능, 손쉬운 온습도 변환장치등을 갖춘 의복내 및 실내 온습도 측정등의 다양한 분야에 활용이 가능한 온습도 측정기와 이에 필요한 센서를 개발하고 개발된 측정기의 선형특성을 평가하였다.

  • PDF

Development of 2-dimensional model for thermal comfort in train (철도 차량 온열 쾌적성에 관한 2차원 모델 개발)

  • Yeon, Bong-Joon;Kim, Moon-Uhn;Kim, Man-Hoe
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.9-16
    • /
    • 2007
  • This study aims to suggest an evaluation method of thermal environment using CFD, not an experiment, which is usual in the field. Model train is the newly introduced Mugunghwa train. Since its compartment occupies a large space and chairs and other accessories make it a complicated structure, 3-D calculation might take too much time and effort to make evaluation itself possible. Therefore, we suggest a 2-D model to replace the original 3-D model for averaged temperature and temperature distribution in the cabin.

  • PDF

Occupant's Thermal Comfort and Heat Gains in CR by PEM (개별공조에 의한 CR에서의 Heat Gain과 재실자 온열성 연구)

  • 김원태
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.13-18
    • /
    • 1999
  • 기존의 공조방식 및 본 연구에서 제안한 개별환경제어시스템(PEM)으로부터 열유체 유동 헤석용 PHOENICS 프로그램을 이용하여 3차원 시뮬레이션을 수행하여 재실자가 거주하고 있는 CR(컴퓨터실)에서의 Heat Gain과 재실자 온열성 특성을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조방식이 실내 환경 개선에 유리하고 diffuser만을 통하여 공기가 유입되어 천정과 바닥으로 공기가 유출되는 PEM 방식은 열적 냉각 성능은 좋으나 PC와 재실자 주변에 강력한 재순환 유동이 발생되어 실내 환경의 쾌적성 측면에서는 불리하나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR실의 재실자 주변 온도 분포에 최적임을 알 수 있다.

  • PDF

Thermoregulation and Clothing Selection Behavior of the Sensitive Person to the Cold (추위에 민감한 사람의 체온조절반응과 의복선택행동)

  • 정운선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.2
    • /
    • pp.199-204
    • /
    • 2000
  • This study was conducted to investigate the thermoregulatory responses and wearing behavior of the cold-sensitive men when exposed to the mild cold of 14$^{\circ}C$. Two sessions of experiment were carried out and five healthy young men for the cold-sensitive group(CSG) and four healthy young for the cold-insensitive group(CIG) participated in the study as subjects CSG maintained rectal temperature lower than CIG due to their thicker clothing resulted in larger decrease of rectal temperature. CSG maintained skin temperatures higher than CIG. CSG felt cooler than CIG but wore thicker clothing for thermal comfort and this made keep their sensation warmer. These results were discussed in terms of autonomic and behavioral temperature regulation.

  • PDF

Thermal Comfort of the Sports/Leisure Clothing with the Heat Storage/Reflection Function - Wearing Evaluation under the Condition of 0x00B1;1℃ and 50±5% RH - (축열/체열반사기능을 가진 스포츠 레저복의 온열쾌적성 - 0±1℃, 50±5% RH 환경에서의 착의평가 -)

  • Kim, Tae-Gyou;Song, Min Kyu;Lee, Chang Min;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.474-481
    • /
    • 2018
  • For this study, we developed clothing in which textile materials that were excellent weather control function for the cold environment and we performed the human subject test with developed clothing to determine the thermal comfort. We used 2 clothing samples developed (A and B, hollow yarn+moisture absorption/quick drying yarn, 3 layers, high stretchable, heat reflection film and lamination treated) and a control sample (Ctrl.) for the human subject test and 8 adult males were used as a human subjects and environmental conditions of chamber were $0{\pm}1^{\circ}C$. $50{\pm}5%RH$, 0.3m/sec. The results were as follows: The average skin temperature and hand, thigh temperature of B were higher than B and Ctrl. (p<.05). The micro-climates of B were near to thermal comfort range which is $32{\pm}1^{\circ}C$ and $50{\pm}10%\;RH$. The chest temperature of B was significantly higher than others (p<.05). The relative humidity of B was lower than others and kept stable rather than others. The thermal sensation of B was near the "neutral" and was significantly different from Ctrl. (p<.01) and the weight loss of B was lower than Ctrl. (p<.05). The counting task and hand temperature was positively related and the counting task value of B and A is bigger than Ctrl. and that of A was bigger than Ctrl. (p<.05).

Thermal Physiological Response of Functional Knitwears for Health and Comfort (건강 쾌적 니트의류가 온열생리반응에 미치는 영향)

  • Kang, Mi-Jung;Kwon, Young-Ah;Kim, Tae-Kyu
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1645-1652
    • /
    • 2007
  • The purpose of this study was to evaluate physiological response and subjective sensation of functional knitwears with different materials and designs. The three different types of knitwears were knitted(polar-neck with cotton/chitosan-C, V-neck with cotton/chitosan-CV and polar neck with cotton/chitosan/silver yarn-CS) and evaluated by four healthy female subjects. Eardrum temperature, mean skin temperature, clothing microclimate, and heart rate were measured in climatic chamber($30^{\circ}C$, 50%RH, 0.5m/sec). The results were as follows. 1. Eardrum temperature was generally evaluated as lower in CV and CS than in C. Mean skin temperature was lower in knitwears with silver yarn than in knitwears without silver yarn. 2. Clothing microclimate temperature on the chest was lower in knitwears with silver yarn than in knitwears without silver yarn. 3. Clothing microclimate humidity was generally lower knitwears with silver yarn than knitwears without silver yarn. 4. Heart rate was lower in knitwears with silver yarn than in knitwears without silver yarn and lower in V-neck than in polar neck. 5. Thermal sensation was slightly warmer in knitwears without silver yarn than in knitwears with silver yarn. Overall comfort sensation was evaluated as more comfortable in CV and CS than in C.

A Study on the Insulation of Thermal Clothing Under Dynamic Air Condition (풍속 존재 시 쾌적보온성 의복의 온열특성에 관한 연구)

  • Song, Min-Kyu;Kwon, Myoung-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.9
    • /
    • pp.29-37
    • /
    • 2008
  • The purpose of this study was to investigate insulation of thermal clothing under still and dynamic air conditions(with 2.1m/sec air velocity) and decrease of insulation in both conditions, to analyze correlations among them, and to estimate insulation and decrease of insulation using factors, such as fabric insulation, fabric weight, clothing weight, air permeability, and water vapor resistance. A total of 25 kinds of clothing were tested(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal resistance of clothing under the dynamic air condition decreased comparing to that of clothing under still air condition in all types of clothing. Decrease in shirts was the biggest(47.5%), followed by suits(39.51%), trousers(37.48%), and jackets(34.49%) in sequence. Thermal resistance of clothing under dynamic air condition showed very high correlation(0.98, p<0.01) with that of clothing under still air condition, followed by thermal resistance of fabric(0.86, p<0.01). Decrease in thermal resistance of clothing showed the highest correlation with air permeability. It didn't show correlation with other factors. Regression analysis showed that fabric thickness would be useful factor for estimating thermal resistance of clothing and air permeability also would be useful factor for estimating decrease in thermal resistance of clothing.

A Study on Acceptable Thermal Comfort Zone and Resident Behavior of Operating Cooling Devices in Apartments (공동주택의 여름철 수용 쾌적온도 범위와 거주자의 냉방기 사용행위에 관한 연구)

  • Chun Chung-Yoon;Bae Nu-Ri
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.477-486
    • /
    • 2005
  • In this study, indoor thermal environment, resident behavior of operating cooling device, and thermal comfort vote are investigated at the living room of apartment during summertime in Seoul. Based on the results of the investigation, indoor air temperatures that residents turn air conditioners (especially for cooling load in this research) on and off were found out. The relationships between outdoor weather condition and the number of days using air conditioner, and whether operating patterns of the devices were also found out. The acceptable thermal comfort zone is figured out from these results, and this research is expected to contribute to the development of household air conditioner. The results can be summarized as the followings; Residents turned the air conditioner on at $29.76^{\circ}C$ of indoor air temperature, and $28.89^{\circ}C$ of $SET^\ast$. And turned the air conditioner off at $27.31^{\circ}C$ of indoor air temperature, and $23.70^{\circ}C$ $SET^\ast$. Therefore, acceptable thermal comfort zone could be lied between these temperatures. If comfortable indoor thermal environment can be obtained with various architectural passive cooling techniques based on the results, energy consumption of cooling devices will be reduced.