• Title/Summary/Keyword: 온실온도

Search Result 540, Processing Time 0.033 seconds

Evaluation and Comparison of Effects of Air and Tomato Leaf Temperatures on the Population Dynamics of Greenhouse Whitefly (Trialeurodes vaporariorum) in Cherry Tomato Grown in Greenhouses (시설내 대기 온도와 방울토마토 잎 온도가 온실가루이(Trialeurodes vaporariorum)개체군 발달에 미치는 영향 비교)

  • Park, Jung-Joon;Park, Kuen-Woo;Shin, Key-Il;Cho, Ki-Jong
    • Horticultural Science & Technology
    • /
    • v.29 no.5
    • /
    • pp.420-432
    • /
    • 2011
  • Population dynamics of greenhouse whitefly, Trialeurodes vaporariorum (Westwood), were modeled and simulated to compare the temperature effects of air and tomato leaf inside greenhouse using DYMEX model simulator (pre-programed module based simulation program developed by CSIRO, Australia). The DYMEX model simulator consisted of temperature dependent development and oviposition modules. The normalized cumulative frequency distributions of the developmental period for immature and oviposition frequency rate and survival rate for adult of greenhouse whitefly were fitted to two-parameter Weibull function. Leaf temperature on reversed side of cherry tomato leafs (Lycopersicon esculentum cv. Koko) was monitored according to three tomato plant positions (top, > 1.6 m above the ground level; middle, 0.9 - 1.2 m; bottom, 0.3 - 0.5 m) using an infrared temperature gun. Air temperature was monitored at same three positions using a Hobo self-contained temperature logger. The leaf temperatures from three plant positions were described as a function of the air temperatures with 3-parameter exponential and sigmoidal models. Data sets of observed air temperature and predicted leaf temperatures were prepared, and incorporated into the DYMEX simulator to compare the effects of air and leaf temperature on population dynamics of greenhouse whitefly. The number of greenhouse whitefly immatures was counted by visual inspection in three tomato plant positions to verify the performance of DYMEX simulation in cherry tomato greenhouse where air and leaf temperatures were monitored. The egg stage of greenhouse whitefly was not counted due to its small size. A significant positive correlation between the observed and the predicted numbers of immature and adults were found when the leaf temperatures were incorporated into DYMEX simulation, but no significant correlation was observed with the air temperatures. This study demonstrated that the population dynamics of greenhouse whitefly was affected greatly by the leaf temperatures, rather than air temperatures, and thus the leaf surface temperature should be considered for management of greenhouse whitefly in cherry tomato grown in greenhouses.

Effects of Shading Rate and Method on Inside Air Temperature Change in Greenhouses (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이현우;이석건;김길동;이종원
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.27-28
    • /
    • 2001
  • 온실의 차광설계에 필요한 기초자료를 제시하기 위하여 온실모형과 실험온실을 이용하여 외부차광재의 적정 설치간격 분석, 차광재별 광투과율 분석, 차광율에 따른 온실내부온도의 변화 분석, 차광이 온실내부의 지온변화에 미치는 영향분석 및 외부차광과 내부차광의 차광효과 비교를 실시하였다. 외부경사차광시 온실 지붕과 차광재의 설치간격은 10-30cm에서 차광효율이 가장 좋은 것으로 나타났으나 환기창의 개폐를 위한 공간이 필요하지 않는 온실에서는 10cm 정도이면 충분한 간격이 될 것으로 판단된. (중략)

  • PDF

Forced Ventilation Number of Air Changes to Set Point of Inside Air Temperature in Summer Glasshouse (여름철 유리온실의 목표온도 유지를 위한 강제환기 회수)

  • 우영회;이정명;남윤일
    • Journal of Bio-Environment Control
    • /
    • v.4 no.2
    • /
    • pp.223-231
    • /
    • 1995
  • Judicious control of high temperature is the most important task for a successful intensive - cultivation in greenhouses during the hot summer. Therefore, the climatological data at 31 locations in Korea were calculated using the modified model equation for ventilated in glasshouses during summer. Furthermore, the adequate number of air- changes or frequency of ventilation was estimated based on temperature settings, which is considered to be more active means of controlling summer glasshouse temperatures, was investigated. The major results can be summarized as follows: Forced ventilation of one air change per minutes was effective in maintaining the maximum air temperature below 35$^{\circ}C$ in the glasshouse haying 40% shading. It was impossible, however, to maintain air temperature below 3$0^{\circ}C$ in 40% shaded glasshouse with forced ventilation only.

  • PDF

Energy Saving Effects of Underground Rock Storage System for Heating of Greenhouse (자갈축열 태양열 온실의 난방에너지 절감효과)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.29-30
    • /
    • 2001
  • 자연에너지원중 태양에너지를 이용한 자갈축열 태양열 온실의 난방에너지 절감효과를 분석하기 위하여 야간에 내부설정온도를 18℃로 했을 때의 자갈축열 태양열 온실과 동일한 제원의 대조온실의 난방연료소비량을 비교하였다. 자갈축열 태양열 온실의 경우 난방초기에는 연료가 대조온실에 비해 약 10%정도 더 소모되었으나 2일이 경과한 후에는 점차 난방연료소비량이 감소하였다(Fig. 2) 이러한 결과는 자갈축열 태양열 온실의 경우 주간에 온실에 투여되는 일사에 의해 축열이 이루어 질뿐만 아니라 야간에 난방을 할 경우에도 축열층의 온도가 설정온도에 도달할 때까지 축열이 이루지기 때문인 것으로 분석되었다 (Fig. 1). 3월 10일부터 3월 15일까지 6일간의 난방연료소비량이 대조온실은 167℃였으나, 자갈축열 태양열 온실은 109℃로써 대조온실에 비해 약 35%정도 난방연료 절감효과가 있는 것으로 분석되었다(Fig. 2). 6일간의 난방 후 자갈축열 태양열 온실에 난방을 중단한 결과 온실외부의 최저기온이 -2.4℃일 때 자갈축열 태양열 온실의 내부최저온도는 14℃를 유지하였으며, 이후 계속 난방을 수행하지 않은 상태에서도 주간에 축열효과로 인하여 최저외기온이 3℃전후일 때 자갈축열 태양열 온실의 내부온도는 15℃를 유지하였으나 대조온실은 5℃ 전후였다. 그리고, 일기온차가 심한 3월말에는 야간설정온도가 18℃인 경우에 자갈축열 태양열 온실의 난방연료소비량이 대조온실에 비해 월등히 적음을 알 수 있었다(Fig. 1, 2). 3월에 자갈축열 태양열 온실의 난방연료소비량은 대조온실에 비해 약 50%이상의 절감효과가 있는 것으로 나타났다./TEX>3.1cm, 2cm$\times$4.2cm 순으로 나타났다. 5. 저고리의 옆길이 곡선에 대한 평가는 진종의 중심인 겨드랑이가 5cm인 것이 가장 우수한 것으로 나타났으며, 그 다음으로 4cm, 6cm, 3cm 순으로 나타났다. 6. 이에 위의 항목들을 종합하여 제작한 연구저고리는 등길이가 28cm, 어깨선 위치는 1.75cm, 깃크기는 5cm$\times$21.5cm, 소매통 크기는 3cm$\times$4.3cm, 옆길이 곡선은 5cm로써 그 형태에 따른 신체적합성에 대한 외관 관능검사 결과로 3.83의 평균값으로 나타났고, 심미성에 대한 외관 관능검사를 항목별 평균치 값으로 종합하면 4.00의 값으로 나타났다. 또한 각 부위별 동작적합성 관능검사는 7가지 동작을 부위별 항목 평균치 결과 3.95의 유수한 저고리로 평가되었다. 본 연구 실험 결과 앞으로도 전통 저고리를 피복함에 있어 외관과 동작적합성이 좋은 저고리를 만들기 위해 지속적 연구가 요청된다. turned back than the Korean women's. Based on the above findings, a torso prototype was developed for the Chinese women by setting the body measurements in reference with their average body measurements plus minimum reserve. The reference lines were set for front/back central line, front/

  • PDF

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.

Analysis of Air Flow for Improving the Heat Storage Efficiency of the Solar-heated Greenhouse with Rock Bed Storage (자갈축열온실의 축열성능 향상을 위한 공기유동 분석)

  • 이석건;이종원;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.195-198
    • /
    • 2003
  • 자갈축열 태양열온실은 주간에 일사로 데워진 온실 내부공기를 온실하부에 설치된 자갈축열층사이로 강제순환시켜 자갈에 에너지를 축열한다. 이러한 축열과 방열과정을 통하여 겨울철 야간에 난방시스템으로 이용하고, 여름철에는 냉방효과를 꾀하게 된다. 온실내 공기가 축열층을 통과하는 동안의 열전달은 강제대류열전달이며, 이 경우 축열층내의 열이동은 축열층내 공기와 자갈표면온도가 초기에는 열적으로 평형상태로 존재하다가 순환공기의 온도상승에 따라 열전달이 일어나게 된다. (중략)

  • PDF

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System (일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.176-181
    • /
    • 2011
  • The fan and pad evaporative cooling system is one of the main cooling methods in greenhouses. Its efficiency is very high, but it has some disadvantages as temperature gradient in greenhouse is large. This study was conducted to reduce the internal temperature gradients in the fan and pad cooling greenhouses. Experiments on cooling performance were carried out in a greenhouse equipped with air duct and integrated fan and pad system as an idea of this study. It showed that the cooling efficiency of an integrated fan and pad system was 75.7% in the first stage and 88.6% in the second stage. When this cooling system was operated for an unshaded and a shaded greenhouse, there were cooling effects of $5.7\sim7.6^{\circ}C$ and $7.4\sim9.7^{\circ}C$ to the control greenhouse, respectively. Maximum temperature differences in a cooling greenhouse, with a length of 18m, were $1.6\sim1.7^{\circ}C$ for shaded conditions and $2.3\sim2.7^{\circ}C$ for unshaded conditions. This greenhouse cooling method, with air duct and integrated fan and pad system, can reduce about 40~50% of the internal temperature gradients in the usual fan and pad cooling greenhouses.

Effects of Shading Rate and Method of Inside Air Temperature Change in Greenhouse (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이석건;이현우;김길동;이종원
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.80-87
    • /
    • 2001
  • This study was conducted to provide basic data for the design of shading facility of greenhouse. The proper distance between external shading screen and roof surface, transmissivity of shading materials, and shading effects of external and internal shadings were analyzed. About a distance of 10 cm between inclined external shading screen and roof surface was enough to guarantee the external shading effect in the greenhouse without roof vent. The inside temperature of greenhouse installed with 85% internal shading screen was lower the maximum of 4$^{\circ}C$ and mean of 2$^{\circ}C$ than that with 55% internal shading screen in both natural ventilation and no ventilation condition. The difference of soil temperature between shading and no shading greenhouse was great, but the difference by shading rate or shading method was small. The performance of external shading for controlling inside temperature down was superior to that of the internal shading. The externally inclined shading screen parallel to the roof surface of greenhouse was more effective than the externally horizontal shading screen in controlling inside temperature of greenhouse without roof vent.

  • PDF