Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance (제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가)

  • Lee, Yeon-Gun;Heo, Jaehyeok;Lee, Dong-Won;Hyun, Myung-Taek
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.70-79
    • /
    • 2018
  • A heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO was constructed with the capacity of 300 RT to supply cool or hot water to greenhouse facilities located 3 km from the power station. The way of transporting heat from the thermal effluent to greenhouses at a long distance was optimized, and a monitoring system to measure the water temperature and detect a leakage in a pipe conduit was also installed. This paper presents the system configuration of the constructed heat pump system for air conditioning and heating of greenhouse facilities in Jeju, and the characteristics of major components deployed in the system. The preoperational tests of the heat pump system were conducted during the summer season in 2018 for evaluation of its cooling performance. The operational stability and cooling performance of the heat pump system were confirmed by investigating the measured fluid temperature and flow rate, and COP of the heat pump in a cooling mode.

Studies on Zone Cooling of Greenhouse in the Daytime in Summer and Occurrence of Blossom - End Rot in Tomato Plants (하기주간의 국소냉방과 토마토 배꼽썩음병 발생에 관한 연구)

  • 조일환;우영회;인과홍중;교본강
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.36-41
    • /
    • 1994
  • The major objective of this study is to develop a method of zone cooling during summer day using heat pump for year- round cultivation. The efficiency of cold water cooling and fog cooling was investigated. In order to prevent the occurrence of blossom - end rot in tomato, cooling was induced together with air flow of the fruit treatment as well as promoting air circulation in the plant treatment was induced. The following results were obtained : 1) The temperature in the cold water cooling district was 1$0^{\circ}C$ lower than greenhouse temperature and the temperature in the fo8 cooling district was about 5$^{\circ}C$ lower than the greenhouse. 2) Regardless of cooling method, the treatment of air flow on fruit did not affect the fruit but prevent blossom-end rot. There was 34.5% occurrence rate of blossom -end rot in non-air flow district of cold water cooling 54.5% in non-air flow district of fog cooling and 78% in fog circulation cooling district. The cooling efficiency using cold water cooling method induced enough cooling at critical temperature for growth and development and the occurrence of blossom -end rot was lower than fog cooling. Fog cooling in culture district with air circulation did not induce and difference in temperature but caused an Increase in humidity resulting in 24% increase in the occurrence of blossom-end rot. Thus the occurrence of blossom-end rot in tomato caused by environmental factors can be attributed more to humidity than to temperature.

  • PDF

The Shading Effect and Wind Velocity Variation of Greenhouse with Fan & Pad System (FAN & PAD시스템 온실의 풍속변화 및 차광효과)

  • 이석건;이종원;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.36-39
    • /
    • 2000
  • 온실용 FAN & PAD 시스템의 설계, 시공 및 운용에 필요한 기초자료를 제공하고자 FAN & PAD 온실의 내부풍속변화와 차광에 따른 냉방성능을 실험적으로 분석한 결과를 요약하면 다음과 같다. 1. FAN & PAD 시스템 온실의 내부풍속은 지면높이 80cm에서는 0.35㎧-1.25㎧ 범위에서 불규칙한 변화를 보였으며, 지면높이 210cm에서는 0.63㎧-1.06㎧ 범위에서 다소 규칙적인 변화를 보였다. 그리고, PAD측 풍속은 지면높이 80cm에서는 평균 0.2㎧, 지면높이 210cm에서는 평균 1.16㎧로 규칙적인 변화를 보였다. 2. 주간(10:00-18:00)에 외기온이 28.2$^{\circ}C$-35.1$^{\circ}C$(평균 31.5$^{\circ}C$)범위에서 변화할 때 FAN & PAD 온실의 내부온도는 외기온보다 평균 2.4$^{\circ}C$-2.7$^{\circ}C$정도 낮게 나타났으며 무차광시 냉방효과가 최고 3.2$^{\circ}C$ 감소하는 것으로 나타났다.

  • PDF

The Cooling Effect Using Pad & Fan in Greenhouse (패드엔팬을 이용한 온실냉방효과)

  • 장유섭;김동억;이동현
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.223-229
    • /
    • 2002
  • 패드엔팬을 이용하여 물 공급량, 팬 회전속도의 변화에 따른 온실 냉방효과 시험한 결과를 요약하면 다음과 같다. 가. 패드에 흐르는 물 공급량별로 일중 11:00-16:00경에 물 공급량이 분당 60$\ell$이상 공급하면 8.0~9.5$^{\circ}C$의 온도차를 낼 수 있으며, 팬을 1170rpm으로 회전시킬 경우 6.0~9.$0^{\circ}C$의 온도차를 낼 수 있었다. 나. 온실과 팬출구 공기의 온도차는 일중 14:30~16:00 경에 60$\ell$이상의 물을 패드에 공급하는 경우 6.0~7.8$^{\circ}C$ 온도 강하 효과가 있고 팬을 1170rpm으로 회전시킬 경우에는 외기온 28$^{\circ}C$일 때 3$0^{\circ}C$이하로 온도를 강하시킬 수 있었다. 다. 패드에 흘리는 물의량을 60 $\ell$/min 이상을 공급하여 주면 30분당 20~28$\ell$의 물을 증발시킬 수 있다. 배출팬 회전속도가 1170rpm일 경우에 30분당 20~30$\ell$의 물을 증발시키는 것으로 나타났다. 라. 본시험에 사용된 패드엔팬의 흡.배기의 엔탈피변화는 8:30이전에는 흡기가 배기보다 온도가 낮아 엔탈피가 양(+)의 값을 나타났고, 8:30 이후에는 흡기가 배기 보다 온도가 높아 -2.0~-4.OkJ/kg의 엔탈피 차만큼 냉각효과가 있었으며, 냉방효율을 65~80% 수준으로 나타났다. 마. 본시험결과로 패드엔팬의 냉기 공급방식만 개선된다면 이동식인 박스형 패드엔팬도 냉방장치로 사용 가능할 것으로 판단된다.

  • PDF

Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

Cooling Effects of Fan and Pad Cooling System (Fan and Pad Cooling System의 냉방효과)

  • 이석건;이종원;이현우;김성식
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.10a
    • /
    • pp.78-81
    • /
    • 1995
  • 시설농업이 상업화되면서 점차 생산시설의 단지화, 대형화 추세가 두드러지고 있으며, 특히 시설농업의 현대화로 고정화, 자동화가 이루어지면서 주년생산을 위한 년중재배체계가 도입되고 있다. 이러한 안정적인 주년생산을 위해서는 우선적으로 해결되어야 할 과제 중 하나가 여름철의 온실 환경관리중 고온극복이다. 하지만 온실내의 미기상중에서 온도를 최소로 유지하는 냉방이 보온보다 어려운 실정이다. (중략)

  • PDF

Analysis for thermal environment in Greenhouse by CFD simulation (CFD 시뮬레이션에 의한 온실의 열환경 분석)

  • 김현수;김문기;김기성
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.80-83
    • /
    • 2000
  • 최근에 CFD 시뮬레이션을 이용한 온실의 공기유동을 해석하려는 시도들이 많이 이루어지고 있다. 그러나 아직 열환경까지를 해석하려는 경우는 드물다. 그러나 여름철의 고온극복을 위해 많은 냉방시스템이 연구되고 있는데 이러한 것들의 이용에 있어서 CFD 시뮬레이션을 이용한 열환경 해석은 중요한 의미를 가질 것이다. 그리고 여러 가지 냉방시스템들 중에서 포그시스템이 효율, 경제적 측면에서 유리하다고 알려져 있다. (중략)

  • PDF

Effect of Root Zone Cooling Using the Air Duct on Temperatures and Growth of Paprika During Hot Temperature Period (공기순환 덕트를 이용한 근권부 냉방이 고온기 파프리카 재배에서 온도와 생육에 미치는 영향)

  • Choi, Ki Young;Jang, Eun Ji;Rhee, Han Cheol;Yeo, Kyung-Hwan;Choi, Eun Young;Kim, Il Seop;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.243-251
    • /
    • 2015
  • This study aimed to determine the effects of root zone cooling using air duct on air temperature distribution and root zone and leaf temperatures of sweet pepper (Capsicum annum L. 'Veyron') grown on coir substrate hydroponic system in a greenhouse. When the air duct was laid at the passage adjacent the slab, the direction of air blowing was upstream at $45^{\circ}$. The cooling temperature was set at $20^{\circ}C$ for day and $18^{\circ}C$ for night. For cooing timing treatments, the cooling air was applied at all day (All-day), only night time (5 p.m. to 1 a.m.; Night), or no cooling (Control). The air temperature inside the greenhouse at a height of 40 and 80cm above the floor, and substrate and leaf temperatures, fruit characteristics, and fruit ratio were measured. Under the All-day treatment, the air temperature was decreased about $4.4{\sim}5.1^{\circ}C$ at the height of 40cm and $2.1{\sim}3.1^{\circ}C$ at the height of 80cm. Under the Night treatment, the air temperature was decreased about $3.4{\sim}3.8^{\circ}C$ at the height of 40cm and $2.2{\sim}2.7^{\circ}C$ at the height of 80cm. The daily average temperature in the substrate was in the order of the Control ($27.7^{\circ}C$) > Night ($24.1^{\circ}C$) > All-day ($22.8^{\circ}C$) treatment. Cooling the passage with either upstream blowing at $45^{\circ}$ or horizontal blowing at $180^{\circ}$ was effective in lowering the air temperature at a height of 50cm; however, no difference at a height of 100cm. Cooling the passage with perpendicular direction at $90^{\circ}$ was effective in lowering the air temperature at the height between 100 and 200cm above the floor; however, no effect on the temperature at the height of 50cm. A greater decrease in leaf temperature was found at 7 p.m. than that at 9. a.m. under both All-day and Night treatments. Fresh weight partitioning of fruit was in the order of the All-day (48.6%) > Night (45.6%) > Control (24.4%) treatment. A higher fruit production was observed under the All-day treatment, in which the accumulated average temperature was the lowest, and it may have been led to a higher proportion of photosynthate distributed to fruit than other treatments.

A Fundamental Study on the Development of Nutrient Solution Cooling System Utilizing Ground Water (지하수를 이용한 양액냉각시스템 개발에 관한 기초적 연구)

  • 남상운;김문기;손정익
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1993.05a
    • /
    • pp.12-13
    • /
    • 1993
  • 우리나라의 기상입지 특성상 여름철 온실 내에서 작물의 정상생육을 기대하는 것은 곤란하므로, 주년재배를 위한 여름철 온실내 환경의 호적화는 온실재배 당면의 연구과제라 할 것이다. 더우기 막대한 일사부하로 인하여 온실냉방은 경제적으로 불가능한 실정이므로 다른 방법을 강구해야 한다. 그런데 수경재배에 있어서는 비교적 근권부환경의 조절이 쉬우므로, 온실의 충분한 환기 및 차광과 더불어 양액의 냉각을 통하여 작물의 고온스트레스를 줄임으로써 안정생산을 가능하게 할 수 있을것으로 생각한다. (중략)