• Title/Summary/Keyword: 온습도분포

Search Result 12, Processing Time 0.03 seconds

Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses (토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.215-224
    • /
    • 2009
  • A survey on the actual state of heating, cooling, ventilation, and air-flow and experimental measurement of temperature and humidity distribution in tomato greenhouse were performed to provide fundamental data required in the development of air-flow control technology. In single-span plastic houses, which account for most of 136 tomato greenhouses surveyed, roof windows, ventilation and air-flow fans were installed in a low rate, and installation specs of those facilities showed a very large deviation. There were no farms installed greenhouse cooling facilities. In the hot air heating system, which account for most of heating type, installation specs of hot air duct showed also a large deviation. The exhaust air temperature and wind speed in hot air duct also were measured to have a big difference depending on the distance from the heater. We are using the maximum difference as indicator to determine whether temperature distribution is uniform. However if the temperature slope is not identical in greenhouse, it can't represent the uniformity. We analyzed relation between the maximum difference and the uniformity of temperature and humidity distribution. The uniformity was calculated using the mean and standard deviation of data from 12 measuring points. They showed high correlation but were represented differently by linear in the daytime and quadratic in the nighttime. It could see that the uniformity of temperature and humidity distribution was much different according to greenhouse type and heating method. The installation guidelines for ventilation and air-flow fan, the spread of greenhouse cooling technology for year-round stable production, and improvement of air duct and heating system, etc. are needed.

Production and Spatiotemporal Analysis of High-Resolution Temperature-Humidity Index and Heat Stress Days Distribution (고해상도 온습도지수 및 고온 스트레스 일수 분포도의 제작과 이를 활용한 시공간적 변화 분석)

  • Dae Gyoon Kang;Dae-Jun Kim;Jin-Hee Kim;Eun-Jeong Yun;Eun-Hye Ban;Yong Seok Kim;Sera Jo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.446-454
    • /
    • 2023
  • The impact of climate change on agriculture is substantial, especially as global warming is projected to lead to varying temperature and humidity patterns in the future. These changes pose a higher risk for both crops and livestock, exposing them to environmental stressors under altered climatic conditions. Specifically, as temperatures are expected to rise, the risk of heat stress is assessable through the Temperature-Humidity Index (THI), derived from temperature and relative humidity data. This study involved the comparison of THI collected from 10 Korea Meteorological Administration ASOS stations spanning a 60-year period from 1961 to 2020. Moreover, high-resolution temperature and humidity distribution data from 1981 to 2020 were employed to generate high-resolution TH I distributions, analyzing temporal changes. Additionally, the number of days characterized by heat stress, derived from TH I, was compared over different time periods. Generally, TH I showed an upward trend over the past, albeit with varying rates across different locations. As TH I increased, the frequency of heat stress days also rose, indicating potential future cost increases in the livestock industry due to heat-related challenges. The findings emphasize the feasibility of evaluating heat stress risk in livestock using THI and underscore the need for research analyzing THI under future climate change scenarios.

Design of Multi-channel Temperature/Humidity Measurement System for Thermal Comfort Evaluatoion (온열쾌적성 평가를 위한 다채널 온습도 분포측정 시스템의 설계)

  • 한화택;김성환;김묘향;박명규;지용주
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.244-248
    • /
    • 2001
  • 본 논문에서는 온열환경 평가를 위한 다채널 온습도 분포측정 시스템을 개발하기 위하여 인체의 쾌적성에 영향을 미치는 온열환경요소를 분석, 이를 적용하기 위한 측정시스템의 설계개념과 요구사양에 고나하여 고찰하였다. 정밀도를 확보하기 위하여 센서의 응답성과 회로의 선형화에 관한 연구를 수행하고 사용자 편의를 도모하기 위한 분석 소프트웨어를 설계하였다. 소프트웨어는 의복내의 온열환경과 실내공간의 온열환경을 분석하기 위한 것으로 나누어져 있고 각각의 소프트웨어는 전처리와 후처리 프로그램 그리고 측정시스템과의 통신 인터페이스를 포함하고 있다. 이와 같은 설계 개념을 반영하여 다채널 온습도 분포측정 시스템이 개발될 경우, 각종 온열환경에 관한 연구에 널리 활용될 수 있을 것으로 기대한다.

  • PDF

Analysis of Temperature and Humidity Distributions according to Arrangements of Air Circulation Fans in Single-span Tomato Greenhouse (토마토 단동온실에서 공기순환팬 설치 방법에 의한 온실 내 온습도 분포 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Paek, Yee;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2016
  • This study was aimed to investigate the effect of air-circulation fans on air temperature and relative humidity in a single-span tomato greenhouse (W: 7m, L: 25m, H: 3.2m). According to standard of fan layout by ASAE (1997), a total of 10 fans were bilaterally arranged in 2 rows in the experimental greenhouse. The distributions of air temperature and relative humidity were measured from 6 pm to 8 am under different conditions, with and without fans. The measurement heights were 0.7m, 1.7m and 2.7m. Under the condition of "fans off", the spatial differences of air temperature and relative humidity between upper and lower sides were $1.7^{\circ}C$ and 10.8%, respectively. The operation of 10 fans showed their differences to $0.1^{\circ}C$ and 3.2%. The number of fans and installation direction were evaluated their performance on reducing the spatial variation of air temperature and relative humidity. The experimental layouts were 5 and fans in 2 rows (bilaterally) and 10 fans in the one (same) direction. Under the condition of "6 fans on" and "5 fans on", the spatial differences of air temperature and relative humidity between upper and lower side were $0.3^{\circ}C$, 3.4% and $0.3^{\circ}C$ and 4.0%. The operation of 10 fans in the one direction reduced their differences to $0.5^{\circ}C$ and 4.9%. The overall findings of this study showed that there was no significant differences under each condition. Therefore, this study suggested that it is more economic and effective to install five fans in 2 rows (bilaterally) in the greenhouse (W: 7m, L: 25m, H: 3.2m).

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

The Characteristic Study of the Microbial Habitat in the Muwisa Museum, Gangjin (강진 무위사 성보박물관 전시실의 미생물 서식환경 특성 연구)

  • Seo, Min Seok;Lee, Sun Myung;Hong, Jin Young
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.333-343
    • /
    • 2013
  • The exhibition hall of museum has been damaged by abundant dust and mold of the air in the room. Occurrence of microorganisms on the surface of the cultural heritage will cause damages such as coloration, materials degradation, deterioration, etc. In this study, we investigated the temperature/humidity and microbes distribution in exhibition hall, display showcase, and on surface of wall paintings in the Muwisa museum. From some samples collected in exhibition hall and display showcase, we identified so many varieties of micro-organisms such as Aspergillus sp., Penicillium sp., Cladosporium sp.. In particular, we could see a large number of microorganisms in the number 1, 2 exhibition hall compared with the number 3 exhibition hall. The results examining the distribution of the temperature and humidity were showed as $28{\pm}4^{\circ}C$ and 70~80%, respectively. The number 1 exhibition showcase was higher humidity environment than the number 2, 3 exhibition hall compared to the distribution ratio, which considered as correlation with the distribution of microorganism concentration. As these results, we understood that high temperature and humidity in the exhibition hall and display showcase of the Muwisa museum were characteristics caused by environmental management and hermetically-sealed rooms.

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System (이류체 포그시스템을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.120-126
    • /
    • 2012
  • Two experiments were designed and executed to measure the effectiveness of the two-fluid fogging system in controlling whiteflies in tomato cultivation. The two-fluid fogging system that lowers temperature and raises humidity in greenhouses provides an eco-friendly method of preventing damages from whiteflies. The first experiment elucidated the effect of fogging treatment on the elimination of whiteflies and investigated the sectional distribution of whiteflies. The second experiment analyzed the vertical distribution, the motility of whiteflies and reduction of the number of whiteflies under the fogging system. The result of the experiments showed that the fogging system lowered the number of whiteflies and decreased their motility significantly. It affected the vertical distribution of whiteflies as well. Based on these experiments, we strongly recommend using the fogging system to prevent and control whiteflies in greenhouses, in addition to installing yellow sticky traps in the areas that have the highest density of whiteflies.

Mechanecal Prolperties of Concerte as the Condition of Contained Water (함수상태에 따른 콘크리트의 역학적성상)

  • 김인수;오창희
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.127-134
    • /
    • 1992
  • Generally speaking, the internal moisture of concrete is mainly distributed in inner part and concrete surface which is exposed are dned according to influence of temperature and humidity. So, the properties which are compressive strength, modular elasticity, and volume change are different at each part even in same concrete. This is because moisture distribution is changed according to the evaporation and move ment of moisture, exist in the inner porosity of concrete. Therefore, it is necessary that we investigate the properties of concrete according to moisture distribution. The purpose of this study is investigating correlation between the moisture content and mechanical properties in concrete. Compressive and tenslle strength decrease according to increasing moisture content, but modular elas ticity increase. Those increasing or decreasing ratio at drying ratio 100% (absolute dries) is as follows in comparative of drying ratio 0 % (saturated condition).tion).

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Analysis and estimation of species distribution of Mythimna seperata and Cnaphalocrocis medinalis with land-cover data under climate change scenario using MaxEnt (MaxEnt를 활용한 기후변화와 토지 피복 변화에 따른 멸강나방 및 혹명나방의 한국 내 분포 변화 분석과 예측)

  • Taechul Park;Hojung Jang;SoEun Eom;Kimoon Son;Jung-Joon Park
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.2
    • /
    • pp.214-223
    • /
    • 2022
  • Among migratory insect pests, Mythimna seperata and Cnaphalocrocis medinalis are invasive pests introduced into South Korea through westerlies from southern China. M. seperata and C. medinalis are insect pests that use rice as a host. They injure rice leaves and inhibit rice growth. To understand the distribution of M. seperata and C. medinalis, it is important to understand environmental factors such as temperature and humidity of their habitat. This study predicted current and future habitat suitability models for understanding the distribution of M. seperata and C. medinalis. Occurrence data, SSPs (Shared Socio-economic Pathways) scenario, and RCP (Representative Concentration Pathway) were applied to MaxEnt (Maximum Entropy), a machine learning model among SDM (Species Distribution Model). As a result, M. seperata and C. medinalis are aggregated on the west and south coasts where they have a host after migration from China. As a result of MaxEnt analysis, the contribution was high in the order of Land-cover data and DEM (Digital Elevation Model). In bioclimatic variables, BIO_4 (Temperature seasonality) was high in M. seperata and BIO_2 (Mean Diurnal Range) was found in C. medinalis. The habitat suitability model predicted that M. seperata and C. medinalis could inhabit most rice paddies.