• Title/Summary/Keyword: 온도 고장

Search Result 279, Processing Time 0.026 seconds

MIL-HDBK-217D를 이용한 전자부품 및 Board의 고장율 계산에 관한 연구

  • Jo, Yeong-So;Im, Deok-Bin
    • ETRI Journal
    • /
    • v.5 no.3
    • /
    • pp.9-15
    • /
    • 1983
  • This paper describes the applicable method of part stress analysis failure rate prediction for electronic components in the MIL-HDBK-217D. The part stress analysis method requires the great amount of detailed informations, such as operating temperature, operating environment, etc. This paper calculates the failure rate of electronic components using the computer program. The program was written by Fortran V and has four basic units as follows (1) Raw data file (2) Failure rate calculation (3) Reliability modelling(Series only) (4) New data file The Functions and structure of the program are illustrated.

  • PDF

Measurement and Analysis for Insulation Deterioration on the Aged Distribution Transformers (변압기 운용 측면에서의 절연 열화 분석 및 측정 기법)

  • Lee, Byung-Sung;Song, Il-Keun;Jeong, Jong-Man;Kim, Byung-Sook;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.109-111
    • /
    • 2005
  • 국내에서 배전용 변압기 제조업체 수는 매년 조금씩 증가하고 있지만 품질향상을 위한 연구가 미흡하여, 전력회사가 요구하는 품질수준을 만족시키지 못하고 있다. 변압기는 전선의 취약부분에서 우선적으로 고장이 발생하게 된다. 정상운전 중 과열점 온도에 의해 절연지가 열 연화되어 고장으로 진전되게 된다. 따라서 변압기의 수명을 결정짓기 위해서는 무엇보다 내부 열특성 해석과 발생된 열에 대한 절연물의 열화 현상을 이해하는 것이 중요하다. 본 연구에서는 변압기 절연지의 열화 현상과 열화로 인한 절연특성 변화메커니즘에 대한 연구를 수행하였다. 절연지의 열화는 변압기 충간의 절연상태를 약화하고 다른 환경적인 요인이 부가될 경우 고장으로 급격히 진전될 수 있다.

  • PDF

The Methodology and Standardization of Burn-in Test for ATM Switching System (ATM 교환기 고온시험방법 및 기준)

  • Jeong, Seung-Guk;Lee, Gyeong-Ho
    • Electronics and Telecommunications Trends
    • /
    • v.12 no.6 s.48
    • /
    • pp.131-135
    • /
    • 1997
  • 본 고는 ATM교환기 고온 상태 동작 특성을 시험하기 위하여 온도 조건, 시험 시간, 시험 절차, 시험 방법, 세부 기준, 판정 기준 등을 정한 것으로, 고온 동작 기준은 한국통신 환경 관리기준 및 품질 표준서-4101을 근거로 하였다. 온도 조건은 평균 $49^{\circ}C$를 유지하되 허용편차는 $1^{\circ}C$내외로 시험되어야 하며, 시험 시간은 온도 상승 및 하강 시간과 장애 발생시 고장 조치 시간 등을 포함하여 최대 72시간을 넘지 않아야 하고, 고온 유지시간은 48시간으로 채택한, ATM 교환기 고온 시험 방법과 기준을 제시하였다.

A Distributed Characteristics of Water in Mineral Oil by Heating (오일에 용존된 수분의 온도 의존성)

  • Kim, Yoon-Hyoung;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.46-48
    • /
    • 2007
  • 수분은 변압기의 절연 상태를 악화시키고 결국은 권선의 단락이나 1, 2차간의 절연 파괴로 이어져 변압기 고장의 주요 원인이 된다. 본 논문에서는 변압기의 절연물인 절연지와 절연유에 대해서 회복전압 측정법을 이용한 열화상태 진단에 대한 측정을 통해 변압기내에 존재하는 수분의 온도 특성을 실험했다. 실험 결과 변압기내 온도에 따른 수분은 절연유보다 절연지의 영향을 크게 받는 것으로 나타났고, 이는 변압기에 사용된 절연지인 셀룰로오스계 절연지의 수분 흡착성이 강하고, 온도가 증가함에 따라 수분을 생성하는 특성 때문인 것으로 판단되었다.

  • PDF

Storage Reliability Assessment of Springs for Turbo Engine Components (터보엔진 구성품용 스프링의 저장 신뢰성 평가)

  • Chang, Mu-Seong;Lee, Choong-Sung;Park, Jong-Won;Kim, You-Il;Kim, Sun Je
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.42-49
    • /
    • 2019
  • This paper presents a method to predict the storage reliability of springs for turbo engine components based on an accelerated degradation test. The reliability assessment procedure for springs is established to proceed with the accelerated degradation test. The spring constant is selected as the performance degradation characteristic, the temperature is determined to be the stress factor that deteriorates the spring constant. The storage tests are performed at three temperature test conditions. The spring constant is measured periodically to check the degradation status of the springs. Failure times of the springs are predicted by using the degradation model. Finally, the storage lifetime of the springs at normal use conditions is predicted using an accelerated model and failure times of all test conditions.

Temperature Properties about SMD Inductor Core of Union Type (일체형 SMD Inductor 코어에 대한 온도 특성)

  • Kim, Ki-Joon
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.32-37
    • /
    • 2010
  • In this study, to develop union type SMD inductor core needs to have the desire of super miniaturization and high reliability, it analyzed temperature properties due to electric power value. As the temperature of electronic parts rise, it bring to technical obstacles that parts can not normal operation, it reduce the span of life to raise the fault ratio. Also, it impact to the parts by heat change power and expansive power, it can not behave exactly, and it have an effect on reliability. It measured the difference value between conditional temperature and parts temperature to union type SMD inductor core. As the results of simulation using D.C. current and resistor($R_dc$), it obtained the excellent regular current values at rising temperature of 40[$^{\circ}C$].

Infrared Thermographic Diagnosis Mechanism for Fault Detection of Ball Bearing under Dynamic Loading Conditions (동적 하중조건에서 볼 베어링의 고장 탐지에 대한 적외선 열화상 진단메커니즘 고찰)

  • Seo, Jin-Ju;Yoon, Han-Vit;Kim, Dong-Yeon;Hong, Dong-Pyo;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.134-138
    • /
    • 2011
  • Fault detection for dynamic loading conditions of rotational machineries was considered from the contactless, non-destructive infrared thermographic method, rather than the traditional diagnosis method. In this paper, by applying a rotating deep-grooved ball bearing, passive thermographic experiment was performed as an alternative way proceeding the traditional fault monitoring. In addition, the thermographic experiments were compared with the vibration spectrum analysis to evaluate the efficiency of the proposed method. Based on the results, it was concluded the temperature characteristics of the ball bearing under dynamic loading conditions were analyzed thoroughly.

Delay Fault Test for Interconnection on Boards and SoCs (칩 및 코아간 연결선의 지연 고장 테스트)

  • Yi, Hyun-Bean;Kim, Doo-Young;Han, Ju-Hee;Park, Sung-Ju
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.2
    • /
    • pp.84-92
    • /
    • 2007
  • This paper proposes an interconnect delay fault test (IDFT) solution on boards and SoCs based on IEEE 1149.1 and IEEE P1500. A new IDFT system clock rising edge generator which forces output boundary scan cells to update test data at the rising edge of system clock and input boundary scan cells to capture the test data at the next rising edge of the system clock is introduced. Using this proposed circuit, IDFT for interconnects synchronized to different system clocks in frequency can be achieved efficiently. Moreover, the proposed IDFT technique does not require any modification of the boundary scan cells or the standard TAP controller and simplifies the test procedure and reduces the area overhead.

$C^3I$ 체계 기술 현황

  • Lee, Jong-Myeong
    • Defense and Technology
    • /
    • no.1 s.155
    • /
    • pp.23-29
    • /
    • 1992
  • 효과적인 $C^3I$체계 구축을 위해서는 조기경보/전장감시용 정보수집장비의 보완이 시급하므로 이에 대한 많은 연구개발 투자가 필요하며 조기경보/전장감시 정보의 신속한 처리/전파를 위한 정보처리 기법을 계속 연구 발전시켜 나가야 할 것이다. $C^3I$체계의 운용 능력 목표 수준은 한반도의 자연환경하에서 온도, 습도, 먼지, 곰팡이 및 이동시 충격등 제약조건에 대한 내구성이 충분하고 24시간 계속 운용이 가능하며, 고장시 복구 및 Back-up 기능이 지원 가능하도록 되어야 할 것으로 본다

  • PDF

DC 블로워 모터의 이상소음 및 진동 진단 시스템 개발

  • 김정욱;김성렬;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.280-280
    • /
    • 2004
  • 기계의 소음 및 진동은 환경요인과 함께 기계의 정밀도 향상 및 고장진단과 관련하여 가장 중요한 분야중 하나이다. 특히 기계의 구동원으로 가장 많이 사용되고 모터는 기계설비이면서도 전기적인 현상으로 작동하기 때문에 설비보전의 사각지대로 나타나고 있다. 또한, 진동으로 모터의 전기적인 결함을 분석하기에는 미흡한 부분이 나타나기 때문에 모터 전용분석 기법을 사용하여 전동기의 전기적 결함을 분석하면 보다 정확한 진단이 가능하다. 현재 일부 생산 현장에서는 모터를 진단하기 위해 진동, 온도, 전류 등의 측정기법 들을 이용하여 분석하고 있다.(중략)

  • PDF