• Title/Summary/Keyword: 온도장

Search Result 1,816, Processing Time 0.026 seconds

A Study on Applicability of Turbulence Models for Unsteady Turbulent Flow with Temperature Variation (온도변화를 수반한 비정상 난류유동장에 대한 난류모델의 적용성에 관한 연구)

  • 유근종;전원대
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 2002
  • The suitable turbulence model is found to be required in the course of establishing a proper analysis methodology for thermal stripping phenomena which are shown in strong temperature variation area such as reactors and propulsion devices. Three different turbulence models of $\kappa$-$\varepsilon$ model, modified $\kappa$-$\varepsilon$ model, and full Reynolds stress(FRS) model, are applied to analyze unsteady turbulent flows with temperature variation. Three test cases are selected for verification. These are vertical jet flows with water and sodium, and parallel jet flow with sodium. Analysis yields the conclusion that 3-D computation with FRS betters others. However, modified modeling is required to improve its heat transfer characteristic analysis. Further analysis is performed to find momentum variation effects on temperature distribution. It is found that the momentum increase results increase of fluid mixing and magnitude of temperature variation.

Systematic Postharvest Quality Management Technology to Improve Marketability of Fresh Ginseng for Export (수출용 수삼 수확후 품질관리기술 체계화)

  • Ji Hyun Lee;Ji-Weon Choi;Min Sun Chang;Sooyeon Lim;Haejo Yang;Il Sheob Shin
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.80-80
    • /
    • 2020
  • 인삼(수삼)은 장기 유통할 때 품질관리에 어려움을 겪고 있고 이는 잘못된 저장, 세척 등의 기술에서 비롯되는 것으로 포장 기술만으로는 고품질 수삼 유통을 실현하기 어렵다. 따라서 연구결과를 토대로 수출용 인삼 수확후 품질관리 과정을 정리하여 매뉴얼화 하였다. 인삼의 수확후 생리적 특성과 품질저하 요인은 물론 수확에서 저장, 세척·건조, 상품성 향상 포장 방법, 냉장컨테이너 적재, 저온 수송 및 판매 시 주의사항 등을 기술하였다. 수삼의 유통 중 손실율에 가장 크게 영향을 미치는 요인은 물러짐과 곰팡이 발생에 의한 부패, 뇌두부위 출아에 의한 상품가치 하락으로 나타났다. 출아는 수확 시기에 따라 다르게 나타나 가을수확 수삼에서는 저장기간 뇌두부위 출아는 전혀 발생하지 않았고, 봄수확 수삼의 경우 수확시기가 늦으면 뇌두 출아가 증가하는 경향을 보였다. 부패 병원균은 25℃ 운송 시 Fusarium spp.가 15, 5, 1℃ 운송 시 Botrytis spp.가 주를 이루었다. 포장단위를 5kg 대포장과 500g 소포장으로 하였을 때 소포장의 물러짐 현상이 대포장보다 훨씬 높게 나타나는 반면 곰팡이 발생에 의한 부패는 대포장보다 낮게 나타났다. 수삼 저장온도에 따라 유통 중 품질이 크게 달라져 온도 -2℃ 이하에 저장한 수삼은 유통 중 손실률이 높고 특품의 비율이 낮아지는 등 품질이 저하되며 저장기간이 길수록 더욱 심화되는 반면 0℃ 저장 수삼은 저장 3개월 후에도 유통 중 품질의 변화가 적었다. 이러한 결과를 종합적으로 정리하여 인삼의 전통적인 수확후 관리 방법이 아니라 수출용 인삼의 품질 향상을 위해 개선된 수확후 관리 방법을 적용할 수 있도록 흐름도로 정리하였다.

  • PDF

Comparative Study of the Flight Test Data and the Prediction Results of PLF Temperature of KSLV-I Using CFD (전산유동해석 기법을 이용한 KSLV-I PLF 구조물 온도 해석 및 비행시험 자료 비교)

  • Kim, Young-Hoon;Ok, Ho-Nam;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • The temperature of the flight objects in high speed increases due to the aerodynamic heating. MINIVER and CFD approach are used to predict the aerodynamic heating conditions of KSLV-I. MINIVER is based on the empirical method. And the CFD approach predicts the aerodynamic heating conditions after the analysis of the surface temperature and the surface heat flux directly. In this study, the aerodynamic heating conditions using CFD approach are considered. The PLF temperature for these aerodynamic heating conditions is compared with the flight test data of KSLV-I.

종이의 유전 특성 향상을 위한 표면 사이즈제의 열적 안정성 및 유동현상 평가

  • 이학래;서만석
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.53-53
    • /
    • 2001
  • 종이의 전기적 성질 가운데 유전율은 전기장에 대한 종이의 물리화학적인 반응으로 일반적으로 종이의 밀도와 종이를 구성하는 성분의 쌍극자 모멘트에 비례하며 온도에 따라서도 변화한다. 일반적으로 온도가 상승하면 열에너지를 얻게된 쌍극자가 전기장에 배열됨으로써 유전율이 상승하지만 온도가 유리전이점 이상으로 높아질 경우에는 열적 교란에 의해서 분극능력이 감소하게 되어 유전완화 현상이 나타난다. 전기절연지로 사 용될 종이의 절연특성을 이해하기 위해서는 사용환경에 따른 유전적 특성 및 tan 0에 관한 연구가 필요하며 필름형성능력이 우수한 polyvinyl a1cohoHPV A)와 acrylonitrile을 이용하여 시아노에틸화한 PYA의 표면처리에 의해 종이의 유전적 특성이 향상되었음을 기존의 연구를 통하여 확인할 수 있었다. 본 연구에서는 전기절연지가 사용되는 환경조건에서 PYA를 기본물질로하는 유전필름 의 열적 안정성을 평가하였으며, 아울러 표면사이징 공정에서의 적용성 검토를 위하여 용액의 유동특성을 분석하였다. 유전특성 향상을 위해서는 표면 사이즈제의 유도체화 과정에서 쌍극자 모벤트의 밀도 증가를 통한 유전율 향상이 요청되며 이와 동시에 네트원 구조를 통하여 전기장에 대 한 물리적 특성이 유지되어야 한다. 본 연구에서는 W AXD( wide angle x-ray diffraction)를 이용하여 시아노에틸화 반응 과 고온에서의 열화에 의한 필름의 결정화도를 평가하였으며 온도 상승에 따른 흡열 피크의 변화를 통하여 온도 변화에 따른 PYA 분자구조의 변화와 유리전이온도의 추이 를 분석하였다. 또 열화과정에서 수반되는 필름의 중량감소율을 평가함으로써 열안정성 을 평가하였다. 그 결과 시아노에틸화한 PYA가 안정된 분자구조를 유지하고 있음을 확인할 수 있었다. 시아노에틸화한 PYA용액의 점탄성 평가를 위하여 storage modulus와 loss modulus 를 분석하였다. 일반적 유변특성 평가 결과 PYA용액은 shear-thinning, pseudoplastic 한 특성을 나타내어 표면사이즈 공정에서의 적용 가능성을 확인할 수 있었다.

  • PDF

A Study of Construction and Efficacy of Thermal Field-Flow Fractionation (열 장 흐름 분획장치의 제작과 효율성에 관한 연구)

  • Dai-Woon Lee;Wook-Hwan Heo;Jeon Sun-Joo;In-Ho Lee
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.3
    • /
    • pp.419-427
    • /
    • 1992
  • The performance of homemade thermal field-flow fractionation (ThFFF) and the optimization for separation are investigated in terms of retention parameters and selectivity using polystyrene standards. The ribbonlike channel was constructed by sandwiching two Mylar spacers between two highly polished copper bars which serve as channel walls. The hot bar was heated by two electrical cartridge heaters and the cold bar had holes through the entire length, allowing tap water as coolant to enter. It has been observed that the retention of polystyrenes increases as the temperature gradient increases. And the retention decreases as the cold wall temperature increases from 20 to $45^{\circ}C$. In comparison with size exclusion chromatography, ThFFF is more selective but has relatively low efficiency. It has been found that the plate height is proportional to the flow velocity and good estimates of polydispersities can be made directly from the ThFFF data.

  • PDF

Electric Quadrupole Interaction in Copper-Iron-Chromium Oxide (구리-철-크롬 산화물에서의 전기사중극자 상호작용)

  • Shu, Seung-Wook;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Ferrimagnetic Copper-Iron-Chromium Oxide $CuFe_{0.9}Cr_{1.1}O_4$ has been investigated over a temperature range from liquid nitrogen temperature upto $N{\acute{e}}el$ temperature using the Mossbauer technique. Its $N{\acute{e}}el$ temperature is found to be 355 K. Above the $N{\acute{e}}el$ temperature the quadrupole splitting is found to be 0.50 mm/s. On the other hand, all the electric quadrupole shift values are zero below the $N{\acute{e}}el$ temperature within experimental error. These seemingly contradictory phenomena have been explained by the model that the magnetic hyperfine field is randomly oriented with respect to the principal axes of the electric-field-gradient tensor.

Finite Element Analysis of Hot Strip Rolling Process (열간박판압연공정의 유한요소해석)

  • 강윤호;황상무
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.829-837
    • /
    • 1992
  • This paper presents a new approach for the analysis of hot strip rolling processes. The approach is based on the finite element method and capable of predicting velocity field in the strip, temperature field in the strip, temperature field in the roll, and roll pressure. Basic finite element formulations for heat transfer analysis are described with emphasis on the treatment of numerical instability resulting from a standard Galerkin formulation. Comparison with the theoretical solutions found in the literature is made for the evaluation of the accuracy of the temperature solutions. An iterative scheme is developed for dealing with strong correlations between the metal flow characteristics and the thermal behavior of the roll-strip system. A series of process simulations are carried out to investigate the effect of various process parameters including interface friction, interface heat transfer coefficient, roll speed, reduction in thickness, and spray zone. The results are shown and discussed.

Numerical Study of Turbine Blade Surface Gas Temperature with Various RPM and Pyro Starter Pressure (파이로 시동기의 압력변화와 터빈 블레이드 회전수 변화에 따른 충동형 터빈 블레이드 입구의 가스온도 분포 해석)

  • Lee, In-Chul;Byun, Yong-Woo;Koo, Ja-Ye;Lee, Sang-Do;Kim, Kui-Soon;Moon, In-Sang;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.94-97
    • /
    • 2008
  • As the partial admission turbine has a intrinsically unsteady and three dimensional flow region, numerical calculation time of these study has been too long time. The numerical analysis for gas temperature of turbine blade surface has been performed to investigate development of temperature with various pyro start pressure. Computations have been carried out several turbine rotational speeds in the range from 0 to 16000 rpm and inlet conditions with 1423K, 7.2MPa. As a result, the more rotational speed and pyro starter pressure of turbine increased, the more turbine blade's temperature decreased. It is also found that flow field of turbine blade inlet area at pyro starter pressure of 5.75MPa and rotational speed of 12100 rpm formed surface temperature uniformly.

  • PDF

New technologies on hot wire anemometry (열선유속계의 신기술)

  • 고상근;이신표
    • Journal of the KSME
    • /
    • v.33 no.9
    • /
    • pp.793-802
    • /
    • 1993
  • 이 글에서는 부 온도저항계수를 갖는 탄소파이버를 열선으로 이용하고 이를 구동한는 증폭회로의 구성에 관한 연구, 3차원 속도측정용 열선프로브의 접지단자를 3개의 열선이 공통으로 사용하는 공통접지 삼축 열선프로브와 유속계의 특성에 대해 고찰한다. 또한 과열비가 다른 두 개의 저 온도형 열선 유속계를 이용하여 유동장의 온도와 속도를 동시에 측정한는 방법과 임의 형태의 유체온도정보를 이용한 열선유속계의 일반적인 온도보상방법에 관하여 논의하여 열선유속계의 원리와 그 응용 등을 간단히 설명함으로써 관심 있는 분들의 이해를 돕고자 한다.

  • PDF

Regeneration of the Retarded Time Vector for Enhancing the Precision of Acoustic Pyrometry (온도장 측정 정밀도 향상을 위한 시간 지연 벡터의 재형성)

  • Kim, Tae-Kyoon;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.118-125
    • /
    • 2014
  • An approximation of speed of sound in the measurement plane is essential for the inverse estimation of temperature. To this end, an inverse problem relating the measured retarded time data in between set of sensors and actuators array located on the wall is formulated. The involved transfer matrix and its coefficient vectors approximate speed of sound of the measurement plane by using the radial basis function with finite number of interpolation points deployed inside the target field. Then, the temperature field can be reconstructed by using spatial interpolation technique, which can achieve high spatial resolution with proper number of interpolation points. A large number of retarded time data of acoustic paths in between sensors and arrays are needed to obtain accurate reconstruction result. However, the shortage of interpolation points due to practical limitations can cause the decrease of spatial resolution and deterioration of the reconstruction result. In this works, a regeneration for obtaining the additional retarded time data for an arbitrary acoustic path is suggested to overcome the shortage of interpolation points. By applying the regeneration technique, many interpolation points can be deployed inside the field by increasing the number of retarded time data. As a simulation example, two rectangular duct sections having arbitrary temperature distribution are reconstructed by two different data set: measured data only, combination of measured and regenerated data. The result shows a decrease in reconstruction error by 15 % by combining the original and regenerated retarded time data.