• Title/Summary/Keyword: 오피스텔건물

Search Result 16, Processing Time 0.026 seconds

Survey Analysis of the Management of Fire Fighting Equipment (소방시설의 관리실태 조사 분석)

  • Mun, Suck-Jin;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.98-103
    • /
    • 2011
  • Currently, domestic architecture has applied the building fire-fighting equipments to most buildings except conventional houses, villas and facilities, and so on. However, the use of fire-fighting equipments what are not working properly result in a human life and property damages consistently like a fire of Icheon warehouse facilities, Korea cold storage, the tragic incident of subway in Daegu and the recent issue of a fire in the high-rise efficiency apartment, etc. In this study, I'm trying to seek solutions by taking research on the actual condition of fire alarming system, fire escaping equipment, Indoor Fire Hydrant Installation.

A study on the relationship between the existing building load for the advance ZEB certification system (ZEB 인증제 고도화를 위한 기존 건축물 부하별 연관성 연구)

  • Lee, Hangju;Maeng, Sunyoung;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.21-27
    • /
    • 2018
  • In accordance with the implementation of the Zero Energy Building Certification System, it for the activation and expansion of the private sector is being steadily upgraded. Also The government has set up a step-by-step mandatory roadmap until it is expanded to the private sector, starting with the public sector. We analyzed the energy requirements of existing buildings from 2016 to 2017 and the by load relationships of major factor. Of the existing buildings, 714 buildings in central and southern areas excluding residential buildings such as apartments and officetels were classified and their primary energy requirements were analyzed. As new design technologies are applied, the demand for energy from the passive side is steadily declining. In addition, there is a need to interpret various methods to improve the zero energy building certification standard in the point that the zero energy building pilot project is continuously carried out in relation to the activation of renewable energy supply.

A Study on Fire Risk of Multi-family Apartment Houses Constructed with the Exterior of the EIFS (외단열시스템 외장재로 시공된 다세대 공동주택의 화재위험에 관한 연구)

  • Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.60-65
    • /
    • 2013
  • EIFS system has the merit of low construction cost and shortening of construction period by easy-to-construct. For such reasons as mentioned above, it has been using across the board such as residential building, school, officetel, building remodeling and so on. It, however, has a drawback of generating plenty of combustible gases from styrofoam which is main material of it. In this regard, measures to prevent losses of life from combustible gases are needed urgently as fires on residential buildings applied EIFS caused human casualties resulted from combustible gases. With respect to the above, this study will analyze the risk of fires on residential facilities, such as multi-family apartment houses, schools and other buildings, applied EIFS which is the most frequently used as material of exterior wall and suggest countermeasure of it.

Study of the Changes in Knowledge Industrial Center Layout Planning Types and Outside Space Composition Elements -Focusing on Guro-gu and Geumcheon-gu in semi-industrial district in Seoul- (지식산업센터 배치유형과 외부공간구성 요소 변화에 관한 연구 -서울 구로구와 금천구 준공업지역을 중심으로-)

  • Lee, Sang-Kyoon;Oh, Joon-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6344-6353
    • /
    • 2014
  • According to the changes in society, the knowledge industrial center, which is a factory related to the manufacturing industry, is now including various programs, such as information and communication knowledge. This study defined the knowledge industrial center related law into three periods: deduct layout planning type and outside space composition elements by previous research; case analysis; and suggestions of the direction of layout planning and outside space plan. As a result of the analysis, first, before 1999, the layout of the building is made mainly with a car, but depending on the form of the site, it is configured as a centered, side layout. Second, in the case of distribution, the support facility on the lower part is integrated and the factory on the higher part is distributed, so it is partly integrated and the building is unified. Third, beginning with the activation of privately owned public space in a semi-industrial district according to architecture regulations in 1999, the outside space is wider but the construction area is reduced, so the outside space composition has been changing in a similar manner to the planning methods of business facilities, such as office buildings.

A Study on the Status of Low-rise Buildings (국내 저층 건축물의 현황에 관한 고찰)

  • Park, Hong-Shin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.28-28
    • /
    • 2011
  • 국내의 건축물에 관한 통계정보는 국토해양부에 의해서 공표된 통계연보로서 2002년부터 매년마다 제공되고 있다.(국토해양통계누리, https : //stat.mltm.go.kr/potal/stat/yearReport.do) 건축물의 통계연보는 과거부터 2002년까지 매 3년마다 공표된 것으로 알려지고 있다. 이 통계연보에는 건축물 현황과 건축허가착공 통계가 수록되어 있다. 건축물 현황에는 2009년 말을 기준으로 기존 건축물이 전체 6,618,131동으로서 용도별, 층수와 연면적별 그리고 소유구분별 등의 구분에 따라 건축물의 동수에 관한 통계자료가 포함돼 있다. 건축허가 및 착공통계에는 용도별과 구조재료별의 분류에 따라 건축물의 동수에 관한 자료가 신축, 증축 개축 이전 대수선, 용도변경 등으로 분류되어 수록돼 있다. 한편 국내에서 건축물에 대한 내진설계기준이 1988년에 제정됨에 따라 법제화되었다. 이때 내진설계의 의무 대상건축물은 6층 이상 또는 연면적 1만$m^2$이상인 건축물로 규정되었다. 그 이후 내진설계 대상 건축물이 1996년부터 아파트는 5층 이상으로, 판매시설은 연면적 5천$m^2$이상으로 확대되었고, 2000년부터 숙박시설 오피스텔 및 기숙사는 5층 이상으로 확대되었으며, 2005년부터 내진설계 의무화 대상이 3층 이상 또는 1천$m^2$이상으로 확대되었고, 2009년부터 3층 이상 건축물의 구조안전의 확인을 위한 세부절차를 규정하여 내진설계의 실효성을 확보하고 있다. 이와 같이 내진설계의 대상 건축물이 내진설계기준을 제정한 이후 현재까지 시대의 흐름에 따라 6층 이상에서 5층 이상으로 다시 3층 이상으로 계속 확대되어왔다. 이런 환경에서 현재 시점에서 사용 중인 기존 건축물 중에 내진설계가 적용되지 아니한 건축물은 1988년 3월 1일 이전에 건축허가 된 건축물과 그 이후에 건축허가 된 3층 내지 5층 이하인 저층 건축물의 두 가지로 구분할 수 있다. 이들의 내진설계가 미적용 된 건축물에 대해서는 원칙적으로 내진보강 대책 수립 및 추진이 필요한 실정이다. 국내에서는 현재 지진재해대책법에 따라 지진재해로부터 국민의 생명과 재산을 보호하기 위하여 기존 시설물에 대한 내진대책을 추진하는 정책이 시행되고 있다. 앞으로는 이 정책의 일환으로 기존 건축물의 내진성능 확보를 위한 내진보강 대책이 구체적으로 추진될 전망이다. 이와 같이 기존 건축물에 대한 내진보강 대책을 수립하는 데는 무엇보다 그 대상 건축물의 수와 구조형식에 관한 정보가 필요하다. 이는 내진보강의 방법과 소요비용이 건축물의 층수 및 구조형식별 동수에 따라 크게 달라지기 때문이다. 이런 관점에서 살펴볼 때 내진대책의 수립에 필수인 기존 저층 건축물의 층수 및 구조형식별 동수에 관한 통계자료를 현재 건축물의 현황통계에서 손쉽게 찾아 볼 수 있으면 좋겠는데 현실은 그렇지 못한 실정이다. 현재 건축물의 현황통계에는 저층 건축물에 해당하는 층수에 관한 구분이 연대에 따라 다르고 구체적인 층수를 구분하기 어렵게 불분명한 항목으로 구성된 것과 구조형식별 분류항목이 없는 형편이다. 반면에 건축허가 및 착공통계자료에는 구조재료별 건축물 동수와 연면적에 관한 자료가 수록되어있고, 건축물 층수에 따라 분류된 통계자료는 없다. 이 연구에서는, 기존 건축물에 대한 내진보강 대책을 수립하는데 필요한 저층 건축물의 층수 및 구조재료별 동수 등에 관한 구체적인 정보를 파악하기 위하여, 건축물 통계연보에 수록된 건축물 현황통계자료에서 불명확하거나 결여된 정보를 건축허가 및 착공 통계자료로부터 얻은 정보로 보완과 보충하여 제시하고 있다. 따라서 이 연구는 기존 건축물의 내진보강 대책 수립에 필요한 5층 이하의 저층 건축물에 관한 층수별 및 구조형식별 동수에 관한 연도별 통계자료를 추정하여 제안하는데 그 목적이 있다.

  • PDF

Influence Factors of Typical Real Estate Development Projects (부동산 개발사업의 유형별 투자결정요인 분석)

  • Lee, Taek-Soo;Lee, Joo-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.1
    • /
    • pp.456-466
    • /
    • 2013
  • The most important thing to develop real estate asset would be a feasibility study. To secure feasibility of development projects, reducing and minimizing the cost of land and construction also would be the important thing. To analyze optimal land-value for real estate development projects, I have collected 204 balance sheets of development projects in South Korea. With the help of statistical technology, I could have selected useful data from those balance sheets. After detailed analysis of statistical data, I could have reached conclusion that the most important factor to earning rate would be land cost per unit ground area under the constraint of given sale price. So far the main pattern of feasibility study of development projects was land cost and construction cost. However, by this study, I have found a new fact that construction cost has little effect to earning rate and land cost per unit ground area is the most effect to earning rate especially in residential facilities rather than commercial ones.