• Title/Summary/Keyword: 오차분리법

Search Result 94, Processing Time 0.028 seconds

Comparative Analysis of Muscle Proteome from Porcine White and Red Muscles by Two-dimensional Electrophoresis (이차원전기영동법을 이용한 white muscle과 red muscle간의 단백질 발현양상의 비교분석)

  • Kim, N.K.;Joh, J.H.;Chu, K.S.;Park, H.R.;Park, B.Y.;Kim, O.H.;Lee, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.731-738
    • /
    • 2003
  • The technique known as proteomics is useful for characterizing the protein expression pattern of a particular tissue or cell type as well as quantitatively identifying differences in the levels of individual proteins. In present study, we carried out the comparative expression patterns of white and red muscles. We used the two-dimensional electrophoresis(2-DE) for analyzing the protein expression. Proteins isolated from porcine white and red muscles were separated by 12% poly-acrylamide gel and then were detected by coomassie blue and silver staining. More than 600 protein spots were detected on each 2-DE gel. By visual analysis of the stained gel, five proteins were identified to be differentially expressed in the white vs red muscle. By database searching based on the molecular weights and pI(isoelectric point) of the five proteins, three of them were found to be most close to troponin I, T and myoglobin. However, further researche is needed for identification and functional analysis of the unidentified proteins. In conclusion, we found five proteins, which are differentially expressed in the white vs red muscle. The functional analysis of the differentially expressed proteins will provide valuable information on biochemical characteristics of the muscle type.

IAEA ICSH Panel on Diagnostic Applications of Radioisotopes in Haematology

  • Noordwijk, Netherlands
    • The Korean Journal of Nuclear Medicine
    • /
    • v.7 no.2
    • /
    • pp.43-46
    • /
    • 1973
  • 이 논문(論文)은 1969년(年) 9월(月) 부터 시작된 IAEA, Internal Society of Hematology 후원(後援)인 ICSH(International Committee for Standardization of Haematology 주최로 열린 제5차 ICSH Panel에서 거론된 Ferrokinetics에 관한 몇 가지 문제점을 초록한 것이다. 1973년 11월 19일 IAEA/ICSH는 Ferrokinetics의 수기(手技)상의 문제점에 관한 토론이 있었다. 즉 혈청철(血淸鐵)이나 총철결합능(總鐵詰合能)을 검사용 혈액 채취시마다 매번 측정해야 되는지에 관한 문제, 환자(患者)의 총철결합능(總鐵詰合能)이 낮을 때 $^{59}Fe$를 주사(注射)하기전 직업적 공혈자(供血者)의 혈장(血漿)과 미리 incubation한 후 주어야 하는지의 문제, 검사용 혈액채취시 그 혈액양, 주입하는 방사성동위원소의 양(量), 항응고제(抗凝固劑)로 Heparin 대신 ACD를 사용할 수 있는지 여부, 통상(通常)의 주사기(注射器)를 사용할 때 그 오차를 줄이는 방법에 관한 문제 방사능(放射能) 계측시(計測時) 혈장(血漿) 대신 전혈(全血)을 사용채도 좋은가에 관한 문제점등이 토론되었다. 여기서 대체로 의견이 일치된 점으로는 주입(注入)하는 $^{59}Fe$는 비방사능(比放射能)이 $5{\mu}Ci/{\mu}g$이상일 것, 이의 양(量)은 체중당(體重當) 얼마로 표시할 것, 방사능계측(放射能計測)에 사용되는 혈액(血液)은 반드시 혈장(血漿)으로 통일할 것, 혈청철(血淸鐵)의 측정(測定)에는 첫번째 및 네번째의 검사용 혈액(血液)을 사용할 것, 혈액(血液)채취후 즉시 혈장(血漿)을 분리(分離)하여 보관할 것, 등(等)에 의견을 모았으며 앞으로 이에 관한 상보(詳報)를 마련하기로 하였다.各) 검사(檢査)에서 계산(計算)된 측정치(測定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던,

  • PDF

A Hybrid Approach for Automated Building Area Extraction from High-Resolution Satellite Imagery (고해상도 위성영상을 활용한 자동화된 건물 영역 추출 하이브리드 접근법)

  • An, Hyowon;Kim, Changjae;Lee, Hyosung;Kwon, Wonsuk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.545-554
    • /
    • 2019
  • This research aims to provide a building area extraction approach over the areas where data acquisition is impossible through field surveying, aerial photography and lidar scanning. Hence, high-resolution satellite images, which have high accessibility over the earth, are utilized for the automated building extraction in this study. 3D point clouds or DSM (Digital Surface Models), derived from the stereo image matching process, provides low quality of building area extraction due to their high level of noises and holes. In this regards, this research proposes a hybrid building area extraction approach which utilizes 3D point clouds (from image matching), and color and linear information (from imagery). First of all, ground and non-ground points are separated from 3D point clouds; then, the initial building hypothesis is extracted from the non-ground points. Secondly, color based building hypothesis is produced by considering the overlapping between the initial building hypothesis and the color segmentation result. Afterwards, line detection and space partitioning results are utilized to acquire the final building areas. The proposed approach shows 98.44% of correctness, 95.05% of completeness, and 1.05m of positional accuracy. Moreover, we see the possibility that the irregular shapes of building areas can be extracted through the proposed approach.

High Performance Liquid Chromatographic Determination of Free Sugars in Ginseng and Its Products (고속액체(高速液體) 크로마토그래피에 의(依)한 인삼(人蔘) 및 인삼제품중(人蔘製品中)의 유리당(遊離糖)의 정량(定量))

  • Choi, Jin-Ho;Jang, Jin-Gyu;Park, Kil-Dong;Park, Myung-Han;Oh, Sung-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.107-113
    • /
    • 1981
  • Free sugars were isolated from ginseng root and its products and analyzed by using high performance liquid chromatogrphy. To isolate free sugars from aqueous sample solution fat-soluble components, crude saponin and protein were removed from the solution by extracting with benzene, water-saturated butanol and 80% ethanol, respectively. Free sugars found from both ginseng root and its products were fructose, glucose, sucrose and maltose, and the only sugar detected from red ginseng root and its products was rhamnose. Major sugar detected from fresh ginseng and white ginseng roots was sucrose, while sucrose and maltose were major sugars of red ginseng root.

  • PDF

Comparison of Multiplex Latex Bead Flow Cytometric Analysis and Quellung Analysis in Serotyping Pneumococci (Multiplex Latex Bead 유세포 분석기 기법과 Quellung 반응을 이용한 폐구균 혈청형 분석 비교)

  • Choi, Kyong Min;Yeon, Soo In;Kim, Eun Sook;Shin, Jeon Soo;Yong, Dong Eun;Lee, Kyoung Won;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.13 no.2
    • /
    • pp.99-105
    • /
    • 2006
  • Purpose : The serotyping results of the Quellung reaction was compared with the newly developed multiplex latex assay and the sensitivity of the Quellung reaction was compared. Methods : We checked the serotypes of 35 samples obtained from patients treated at Yonsei University Medical Center using the multiplex latex bead method and compared the results with the serotypes previously obtained via the Quellung reaction. Results : A decrease in the mean fluorescence was detected in the samples tested with the multiplex assay. Seventeen samples out of the 27 samples agreed to the results of the Quellung assay. We were only able to confirm the concordance of 11 serotypes out of 14 serotypes available. Conclusion : The Quellung reaction is time consuming procedure and prone to errors even with expertise in the procedure, and other alternate methods in serotyping have been investigated to overcome these problems. The newly developed multiplex latex bead assay can test more samples at the same time and has a higher degree of sensitivity. A large scale trial is required to test the sensitivity of the new assay across various serotypes along with efforts to increase the sensitivity of the Quellung assay. The preliminary data suggests that this method may be widely used.

  • PDF

Development of an Analytical Method for Fluxapyroxad Determination in Agricultural Commodities by HPLC-UVD (HPLC-UVD를 이용한 농산물 중 Fluxapyroxad 잔류분석법 개발)

  • Kwon, Ji-Eun;Kim, HeeJung;Do, Jung-Ah;Park, Hyejin;Yoon, Ji-Young;Lee, Ji-Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.234-240
    • /
    • 2014
  • Fluxapyroxad is classified as carboxamide fungicide that inhibits succinate dehydrogenase in complex II of mitochondrial respiratory chain, which results in inhibition of mycelial growth within the fungus target species. This study was carried out to assure the safety of fluxapyroxad residues in agricultural products by developing an official analytical method. A new, reliable analytical method was developed and validated using High Performance liquid Chromatograph-UV/visible detector (HPLC-UVD) for the determination of fluxapyroxad residues. The fluxapyroxad residues in samples were extracted with acetonitrile, partitioned with dichloromethane, and then purified with silica solid phase extraction (SPE) cartridge. Correlation coefficient($R^2$) of fluxapyroxad standard solution was 0.9999. The method was validated using apple, pear, peanut, pepper, hulled rice, potato, and soybean spiked with fluxapyroxad at 0.05 and 0.5 mg/kg. Average recoveries were 80.6~114.0% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.01 and 0.05 mg/kg, respectively. All validation parameters were followed with Codex guideline (CAC/GL 40). LC-MS (Liquid Chromatograph-Mass Spectrometer) was also applied to confirm the analytical method. Base on these results, this method was found to be appropriate fluxapyroxad residue determination and can be used as the official method of analysis.

A Novel Volumetric Method for Quantitation of Titanium Dioxide in Cosmetics (용량분석법을 이용한 화장품 중 티타늄옥사이드의 정량)

  • Kim, Young-So;Kim, Boo-Min;Park, Sang-Chul;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.289-293
    • /
    • 2005
  • Nowadays there are many sun protection cosmetics including organic or inorganic UV filter as an active ingredient. Chemically stable inorganic sunsEreen agents, usually metal oxides, we widely employed in high SPF products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as pigments for a long period of cosmetic history. With the development of micronization techniques, it becomes possible to incorporate titanium dioxide in sunscreen formulations without whitening effect and it becomes an important research topic. However, there are very few works related to quantitations of titanium dioxide in sunscreen products. In this research, we analyzed amounts of titanium dioxide in sunscreen cosmetics by adapting redof titration, reduction of Ti(IV) to Ti(III) and reoxidation to Ti(IV). After calcification of other organic ingredients of cosmetics, titanium dioxide is dissolved by hot sulfuric acid. The dissolved Ti(IV) is reduced to the Ti(III) by adding aluminum metals. The reduced Ti(III) is titrated against a standard oxidizing agent, Fe(III) (ammonium iron(III) sulfate), with potassium thiocyanate as an indicator In order to test accuracy and applicability of the proposed method, we analyzed the amounts of titanium dioxide in four types of sunscreen cosmetics, such as cream, make-up base, foundation and powder, after adding known amounts of titanium dioxide $(1{\sim}25w/w%)$. The percent recoveries of the titanium dioxide in four types of formulations were in the range between 96 and 105%. We also analyzed 7 commercial cosmetic products labeled titanium dioxide as an ingredient and compared the results with those of obtained from ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry), one of the most powerful atomic analysis techniques. The results showed that the titrated amounts were well coincided with the analyzed amounts of titanium dioxide by ICP-AES. Although instrumental analytical methods, ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) and ICP-AES, are the best for the analysis of titanium, it is hard to adopt because of their high prices for small cosmetic companies. It was found that the volumetric method presented here gat e quantitative and reliable results with routine lab-wares and chemicals.

A Study on the Effect of Sample Storage Condition on the RIA Results of Plasma renin activity Test (Plasma renin activity 검사의 검체 보관 방법이 방사면역 측정법 결과에 미치는 영향에 대한 고찰)

  • Choe, Jin-joo;Back, Song-ran;Yoo, Seon-hee;Lee, Sun-ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.29-33
    • /
    • 2021
  • Purpose Plasma renin activity (PRA) test is important for the diagnosis of primary aldosteronism. PRA is an easily deformed substance in vitro and affected by temperature changes. Laboratory of ASAN medical center has consistently found that there was a difference between the initial and re-experimental results. We compared and analyzed the differences in PRA test results according to the sample storage status. Materials and Methods The measurement of PRA was performed by using the radioimmunoassay. From August to September 2020, 43 PRA re-test samples were tested with different sample storage condition. The first group was re-examined by freezing the plasma-separated samples at -18℃, and the second group was re-examined with refrigerated EDTA sample. Also, additional tests were conducted on 13 PRA samples to verify the effect on thawing temperature differences in plasma-separated samples. The same samples were divided into two parts and stored frozen at -18℃, respectively, and thawing samples in room temperature and those in refrigerator were were conducted. Each result was compared and analyzed based on the initial experimental results. Results The results of re-examination after frozen storing plasma separation samples showed a lower correlation than the results of re-examination with EDTA plasma samples in refrigerator. When calculating the percentage based on the initial test results, the average percentage of each was 404.9% and 133.8%. The correlation coefficient was also R=0.8501 and R=0.9966, respectively, showing a higher correlation between plasma in the refrigerated sample EDTA tube. In comparison experiments with differences in thawing temperature, average percentage of the results of initial test and room temperature thawing was 94.3% and the average percentage of the results of refrigerated thawing was 88.0%. After again freezing the sample, the average percentage of the second room temperature thawing result is 107.5%, and the second refrigerated thawing group is 112.7%. Both groups showed an increase from first thawing. Conclusion A comparative analysis of retesting according to differences in sample storage methods in PRA tests showed a higher correlation between the results of retesting of the refrigerated EDTA plasma. And repeated freezing and melting of plasma separation samples, regardless of temperature during defrosting, has been shown to affect results. Therefore, retest of PRA should re-collect plasma from original EDTA plasma to increase reproducibility.

Determination of Tumor Boundaries on CT Images Using Unsupervised Clustering Algorithm (비교사적 군집화 알고리즘을 이용한 전산화 단층영상의 병소부위 결정에 관한 연구)

  • Lee, Kyung-Hoo;Ji, Young-Hoon;Lee, Dong-Han;Yoo, Seoung-Yul;Cho, Chul-Koo;Kim, Mi-Sook;Yoo, Hyung-Jun;Kwon, Soo-Il;Chun, Jun-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.59-66
    • /
    • 2001
  • It is a hot issue to determine the spatial location and shape of tumor boundary in fractionated stereotactic radiotherapy (FSRT). We could get consecutive transaxial plane images from the phantom (paraffin) and 4 patients with brain tumor using helical computed tomography(HCT). K-means classification algorithm was adjusted to change raw data pixel value in CT images into classified average pixel value. The classified images consists of 5 regions that ate tumor region (TR), normal region (NR), combination region (CR), uncommitted region (UR) and artifact region (AR). The major concern was how to separate the normal region from tumor region in the combination area. Relative average deviation analysis was adjusted to alter average pixel values of 5 regions into 2 regions of normal and tumor region to define maximum point among average deviation pixel values. And then we drawn gross tumor volume (GTV) boundary by connecting maximum points in images using semi-automatic contour method by IDL(Interactive Data Language) program. The error limit of the ROI boundary in homogeneous phantom is estimated within ${\pm}1%$. In case of 4 patients, we could confirm that the tumor lesions described by physician and the lesions described automatically by the K-mean classification algorithm and relative average deviation analyses were similar. These methods can make uncertain boundary between normal and tumor region into clear boundary. Therefore it will be useful in the CT images-based treatment planning especially to use above procedure apply prescribed method when CT images intermittently fail to visualize tumor volume comparing to MRI images.

  • PDF

Evaluation of microplastic in the inflow of municipal wastewater treatment plant according to pretreatment methods (전처리 방법에 따른 하수처리장 유입수에서의 미세플라스틱 성상분석 평가)

  • Kim, Sungryul;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.83-92
    • /
    • 2022
  • The amount of the plastic waste has been increasing according to global demand for plastic. Microplastics are the most hazardous among all plastic pollutants due to their toxicity and unknown physicochemical properties. This study investigates the optimal methodology that can be applied to sewage samples for detecting microplastics before discussing reducing microplastics in MWTPs. In this study, the effect of different pretreatment methods while detecting microplastic analysis of MWTP influent samples was investigated; the samples were collected from the J sewage treatment plant. There are many pretreatment methods but two of them are widely used: Fenton digestion and hydrogen peroxide oxidation. Although there are many pretreatment methods that can be applied to investigate microplastics, the most widely used methods for sewage treatment plant samples are Fenton digestion and H2O2 oxidation. For each pretreatment method, there were factors that could cause an error in the measurement. To overcome this, in the case of the Fenton digestion pretreatment, it is recommended to proceed with the analysis by filtration instead of the density separation method. In the case of the H2O2 oxidation method, the process of washing with distilled water after the reaction is recommended. As a result of the analysis, the concentration of microplastics was measured to be 2.75ea/L for the sample using the H2O2 oxidation method and 3.2ea/L for the sample using the Fenton oxidation method, and most of them were present in the form of fibers. In addition, it is difficult to guarantee the reliability of measurement results from quantitative analysis performed via microscope with eyes. A calibration curve was created for prove the reliability. A total of three calibration curves were drawn, and as a result of analysis of the calibration curves, all R2 values were more than 0.9. This ensures high reliability for quantitative analysis. The qualitative analysis could determine the series of microplastics flowing into the MWTP, but could not confirm the chemical composition of each microplastic. This study can be used to confirm the chemical composition of microplastics introduced into MWTP in the future research.