A Study on the Thermal Performance of an Oil Cooler with Dual-cell Model (듀얼셀 모델을 이용한 오일쿨러의 방열성능 연구)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1111-1116
    • /
    • 2011
  • Heat exchangers have been used for the automotive, HVAC systems, and other various industrial facilities, so the market is very wide. In general, high-efficiency heat exchangers with louver fins are used in the dust-free environment while heat exchangers with wavy fins are used for dusty environment such as construction site, etc. In this study, numerical analysis has been performed for typical heat exchangers, used as oil coolers or fuel coolers, with dual cell model that can handle different grids for the air-side and oil-side of heat exchangers. First wind tunnel tests were conducted to obtain one-dimensional thermal performance data of heat exchangers. Then, heat release rates with varying air flows were numerically predicted using the three-dimensional dual-cell model. The model can greatly enhance the accuracy of thermal design since it includes the effects of nonuniformity of air flows across heat exchangers.

A NUMERICAL STUDY ON THE CONJUGATE HEAT TRANSFER OF AN OIL COOLER WITH OFFSET STRIP FINS FOR VARIOUS-FLOW RATES (오일의 유량 변화와 오프셋 스트립 휜을 고려한 오일쿨러의 복합열전달 해석)

  • Park, S.W.;Choi, H.G.
    • Journal of computational fluids engineering
    • /
    • v.19 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • Conjugate heat transfer of an automotive oil cooler with offset-strip fins was numerically investigated to predict the performance of the oil cooler for various flow-rates. The simulations were conducted by directly modeling offset-strip fins with unstructured meshes. The incompressible Navier-Stokes equations coupled with energy equation were used for the present simulations. Heat transfer characteristics of the oil cooler was compared well with experimental results and the errors were approximately within 5 percents. It was found that the performance of the oil cooler increased as the flow-rate increased up to the flow-rate of 12 L/min, but the performance seemed to be saturated beyond a critical flow-rate, which was estimated as 15 L/min. Furthermore, it was confirmed that compared to the performance without fins, that of the oil cooler with offset-strip fins was increased by about 75 percents.

Study of Development of a Dust-proof Oil Cooler (내분진형 오일 쿨러 개발에 관한 연구)

  • Lee, Young-Lim;Jeon, Euy-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.60-65
    • /
    • 2008
  • A typical louvered-fin oil cooler can be easily contaminated under dusty environment hence resulting in poor performance of a heat exchanger. Thus, in this study, a dust-proof oil cooler has been studied with a unique shape of a 3-dimensional wavy fin since non-louvered fins could have better performance under dusty environment compared to louvered fins. Recently, they have been introduced to commercial and constructional vehicles in Japan. At first numerical analysis has been done to optimize the angle of the wavy fin so that the oil cooler developed can satisfy the target performance. The wavy fin has been then made with roll-forming and roll-pitch stands, and a prototype of an oil cooler with the wavy fin has been finally built with brazing. The performance test showed that the heat release rate of the oil cooler was well beyond the target, 4.94kW and the air-side pressure drop was below the criterion, 0.19kPa. In addition, the results showed that the numerical prediction was effective enough to design the dust-proof oil cooler that satisfies the performance criteria.

Performances of Hot Gas Bypass Type Oil Cooler System (Hot Gas를 이용한 오일쿨러의 성능평가)

  • Lee, Seung-Woo;Yeom, Han-Kil;Park, Kil-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-80
    • /
    • 2009
  • In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with machine tools. For precise temperature control, both cooling and heating should be implemented. A hot gas bypass type cooling cycle method has a simplified structure and temperature control accuracy to with in ${\pm}0.1^{\circ}C$. In this study, the performances of oil cooler system, including temperature controllability according to hot gas floe and preset temperature sustainability according to temperature load, were tested. It is expected that this study will contribute to the development and performances of oil cooler system, which could minimize thermal errors and improve the quality of precision machine tools.

Heat Transfer Characteristics according to the Tube Arrangement of Bundle Type Plastic Oil Cooler (플라스틱 관다발 타입 오일쿨러의 튜브 배열에 따른 열전달 특성)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Kim, Hyun-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • It has been argued that the use of plastics can cause problems during design and manufacture owing to their low strength, relatively poor thermal conductivity and large thermal expansion. However, the advantages of plastics e.g., corrosion resistance, low cost, curtailment of weight, design flexibility etc., can compensate abundantly for the disadvantages. This study analyzes and compares the heat transfer performance characteristics of automotive compact oil cooler composed of plastic tube bundle with conventional metal oil cooler on the same core area basis as diameter, tube thickness, number of tube or tube arrangement varies. The performance analyses are accomplished by use of computational fluid dynamics program Fluent 6.2, which is verified and compared with the results of performance tests. The result of analyses is coincided with that of experiments. Flow pattern at air side according to tube arrangement is dominant factor which affects heat dissipation in case of similar total heat transfer surface area.

The development of cooling system in the gasoline engine with the aluminum alloy cylinder block (알루미늄 합금 실린더 블럭을 적용한 가솔린 엔진의 냉각계 개발)

  • 한덕주;민병순;최재권
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.17 no.3
    • /
    • pp.11-18
    • /
    • 1995
  • 본 논문에서는 주철 라이너를 삽입한 알루미늄 블럭 엔진 개발과정에서 주조 불량이 발생하였을때, 냉각계에 일어나는 제반 현상을 분석하고, 이를 해결해 나가는 과정을 기술하였다. 이를 위하여 주철 블럭과 알루미늄 블럭을 장착한 엔진의 피스톤 온도와 블럭의 열유속, 열정산을 측정하였다. 측정한 결과는 다음과 같다. 1. 알루미늄 블럭 제작시 주철 라이너와 알루미늄 블럭 사이에 공기층이 크거나, 용탕 충진이 불완전한 주조 불량이 발생하면 열접촉 저항이 커져 엔진 열전달 경로에 큰 영향을 준다. 2. 알루미늄 블럭 제작시 주조 불량이 발생하면 피스톤에서 라이너로의 전열량이 줄어듦에 따라 냉각수로의 전열량은 감소하는데, 6,000rpm, 전부하에서 알루미늄 블럭의 출력 대비 냉각수로의 방열량의 비는 38.3%이고, 주철 블럭은 44.1%이다. 3. 알루미늄 블럭 제작시 주조 불량이 발생하면, 피스톤 온도가 15-20.deg.C 정도 상승하여 피스톤 손상을 유발시킬 수 있다. 4. 알루미늄 블럭의 주조가 완벽하게 되어 주철 라이너와 알루미늄 몸체 사이에서의 열접촉저항이 없어지면, 스토로크 방향에 따른 금속면 온도 분포가 균일하게 된다. 5. 실린더 라이너의 주조상태 개선없이 오일젯을 사용한 결과 피스톤의 온도를 만족할 만한 수준으로 감소시켰다. 6. 6000rpm, 전부하에서 오일젯 적용시 출력 대비 냉각수로의 방열량의 비가 38.3%에서 36.2%로 감소하고, 출력대비 오일로의 방열량의 비는 9.6%에서 11.2%로 증가한다. 7. 오일젯 작용시 오일 펌프의 용량 증대와 오일 쿨러의 장착이 필수적이다.

  • PDF

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.

클린룸 내 스프링쿨러 소화설비 시공사례

  • 김형겸
    • Air Cleaning Technology
    • /
    • v.17 no.4 s.67
    • /
    • pp.58-68
    • /
    • 2004
  • 국내 반도체, TFT-LCD, PDP 등의 제조공장 클린룸 내부의 스프링클러 소화설비는 90년대 말까지는 소화설비의 오 작동에 의한 고가 생산 장비의 물 피해가 우려 되어 면제가 되어왔으나, 1998년 대만 반도체 공장의 대형 화재사건이 발생한 이후로는 영미계 재 보험사들의 강력한 요청에 의하여 국내 관련 제조시설 내부에도 스프링클러 소화설비는 의무화 되고 있는 실정이다. 본 글에서는 반도체 제조공장의 소화설비의 특성을 중심으로 클린룸 내의 스프링클러 소화설비 시공사례를 소개하여 관련업계 관계자들의 이해를 돕고자 한다.

  • PDF

Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control (PI와 피드포워드 제어를 이용한 공작기계용 오일쿨러의 핫가스 바이패스 방식 정밀 온도 제어)

  • Jeong, Seok-Kwon;Byun, Jong-Yeong;Kim, Sang-Ho;Yoon, Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-119
    • /
    • 2011
  • Recently, the performances of speed and accuracy are enhanced in machine tools. The high speed of the machine tools usually causes harmful thermal displacements on the objects. To reduce the thermal displacements, machine tools generally adopt oil coolers with precise temperature control function. This study aims at precise control of oil outlet temperature in the oil coolers with hot-gas bypass manner based on PI control logic. The control system was designed for obtaining steady state error within ${\pm}0.1^{\circ}C$ and maximum overshoot with 0.8% even though abrupt disturbances are added to the system. We showed that the PI gains could be easily decided by numerical simulations using practical transfer function which got experiments. Also, transient characteristics could be improved significantly by reflecting the inlet temperature of an evaporator to the output of a controller feedforwardly considering periodic abrupt disturbances. Through some experiments, excellent control performances were established by the suggested control.