• Title/Summary/Keyword: 오일 온도제어

Search Result 65, Processing Time 0.025 seconds

A Study on the Calibration Technique of an Electrical Temperature Calibrator (전기식 온도 교정기 교정기법 연구)

  • Oh, Kwang-Suk;Lee, Wang-Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.944-951
    • /
    • 2016
  • Resistance temperature detectors (RTDs) and thermocouple sensors are broadly used to measure temperatures in the engineering and research fields. The contents of this standard calibration procedure (SCP) describe procedures related to the calculation of an electrical temperature calibrator and show different ways to indicate the calibration results, such as measurement uncertainty. As an SCP for the electrical temperature calibrator has not been developed yet, we studied the SCP and found a solution to this problem. In this paper, we present a mathematical model of the data and measurement variations with the calibration data results.

실리콘 다이오드를 적용한 다채널 중성 입자 분석기 개발

  • Cheon, Se-Min;Jwa, Sang-Beom;Gang, In-Je;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.211-212
    • /
    • 2011
  • 플라즈마를 제어하기 위해서는 플라즈마의 온도, 밀도, 에너지 분포등과 같은 플라즈마의 특성을 정확히 측정할 수 있어야한다. 핵융합발전에서는 플라즈마를 발생하기 위하여 플라즈마의 온도, 밀도 등 각종 변수들을 시공간적으로 계측, 분석할 수 있는 진달설비를 사용하고 있으며, 정확한 플라즈마 제어와 측정을 위한 새로운 진단기술을 개발하고 있다. 그리고 중요한 변수중에 하나인 플라즈마 이온온도를 측정하기 위해 중성입자 검출법이 잘 알려져 있다. 이 실험은 수소 중성입자가 토카막 내부의 플라즈마 이온과 충돌하면서 생성된 고속 중성입자의 에너지를 분석하는 실험이다. 본 연구의 실험방법은 수소 중성입자를 이온빔 장치에서 이온화 시킨 후 자체 제작한 가속기를 통하여 가속시켜 에너지 특성을 분석을 하는 것이다. 본 연구의 실험장치로 에너지 교정용 100 keV 이온빔 소스를 제작 하였고 이온빔 장치 내부에 수소기체를 주입하고 기체방전을 일으켜 플라즈마를 발생시켰다. 이온빔 외부에는 팬을 설치하고 전도성이 강한 물 대신 전도성이 약한 오일을 사용하여 냉각 하였다. 이온빔 장치와 결합될 이온 가속장치는 지름 300 mm, 두께 2 mm의 원형 구리판을 여러층으로 쌓아 전극으로 제작하였고 전극과 전극 사이에서 코로나 방전과 스파크를 방지하기 위해 전극 둘레에 코로나링을 설치 하였다. 또한 전극 사이마다 1G${\Omega}$의 저항을 설치한 후 고전압을 생성하여 이온 가속 효율을 증대시켰다. 진공시스템으로는 Alcatel사의 CFF100 터보분자 펌프와 우성진공사의 MVP24 진공로타리펌프를 결합하여 사용하였으며, 진공도측정은 Alcatel사의 ACS1000 장치를 사용하였다. 고진공후 고속 중성입자의 이온화와 에너지 측정을 위한 전하교환기를 설치하였다. 전하교환기로는 진공시스템을 별도로 설치하고 비용이 비교적 많이 드는 기체형 전하교환기 대신 소형화가 가능하고 유지보수가 좋은 고체형 전하교환기 제작하여 실험 하였다. 전하교환기에서 이온화된 고속 중성입자가 전기장이나 자장에 영향을 받았을때 에너지분포를 디텍터를 통해 측정하였다. 즉, 이온화된 중성입자의 에너지가 실리콘 다이오드를 통해 전압 펄스 신호로 변환되고 이차 증폭기를 통해 전압 펄스 신호들이 증폭한다. 에너지 측정을 위한 디텍터는 소형화가 가능하고 비용이 비교적 적게 드는 실리콘 다이오드를 설치하였다. 본 연구결과 중성입자 에너지 분석 장치가 실제 핵융합 장치의 플라즈마 이온온도와 특성 측정에 적용할 수 있으며, 앞으로 개발될 여러 형태의 응용 플라즈마 발생장치의 플라즈마 진단에 이용될 것으로 기대한다.

  • PDF

A Study on the Real-Time Oil-Spill Monitoring Technology (실시간 기름유출 모니터링 기술에 관한 연구)

  • Yeom, Woo-jung;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.472-477
    • /
    • 2017
  • Oil spills cause a lot of damage to the environment. Oil destroys the water environment and ecosystem in a very short period of time once they are contaminated by it, it takes a lot of time to recover from the contamination and the cleaning process is very difficult. Therefore, oil detectors are greatly needed as they can monitor any oil spills over the sea, rivers, and lakes. There are two kinds of technology available for detecting oil, viz. the contact and non-contact types. The former is based on the use of the conductivity, capacitance and microwaves, while the latter employs infrared, UV, laser, optic and radar technologies. As there are also various hurdles in the measuring of oil on water, such as the presence of waves, refraction of light, temperature and saltiness, it is imperative to select the right oil detector which is appropriate for the specific environment. In this study, a contact type oil detector is developed, which can be used in oil related industries, such as refineries, petrochemical companies, and power generation stations. The detector is made up of the sensor module, which floats on the water, and the controller which processes the signal coming from the sensor module and displays it. It is designed in such a way that the existence of oil is detected through the sensor and the change in the permittivity is observed to determine the volume and type of spilled oil.

Thermal and Flow Analysis of a Driving Controller for Active Destruction Protections (능동 파괴 방호 구동제어기의 열 유동 해석)

  • Ryu, Bong-Jo;Oh, Bu-Jin;Kim, Youngshik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.235-242
    • /
    • 2017
  • A driving controller for active destruction protections can be applied to machinery, aerospace and military fields. In particular, this controller can be used to track and attack enemy flying objects through the active control. It is important to ensure reliability of the driving controller since its operation should be kept with precision to the target point. The temperature of the environment where the driving controller is used is about -32 C ~ 50 C (241~323 ). Heat generated in the driving controller should be maintained below a certain threshold (85 C (358 )) to ensure reliability; therefore, the study and analysis of the heat flow characteristics in the driving controller are required. In this research, commercial software Solid-Works Flow Simulation was used for the numerical simulation assuming a low Reynolds number turbulence model and an incompressible viscous flow. The goal of this paper is to design the driving controller safely by analyzing the characteristics of the heat flow inside of the controller composed of chips or boards. Our analysis shows temperature distributions for boards and chips below a certain threshold.

The control of poly-grain and internal cavities for high-quality $CaF_2$ single crystal growth of 6inch in diameter (고품질의 직경 6 inch 형석($CaF_2$)단결정 성장을 위한 poly-grain 및 내부 cavity제어)

  • Seo, Soo-Hyung;Joo, Kyoung;Auh, Keun-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.550-554
    • /
    • 1998
  • We suggested the new method of thermal screen in Bridgman-Stockbarger method to control the polygrain, the internal cavities and solid-liquid (SL) interface. $CaF_2$ single crystal of 6 inch was grown perfectly when we adopted to use a graphite pipe and a ceramic warmer in the conditions of growth rate 2 mm/hr, vertical temperature of $14^{\circ}C$ for freezing and temperature of $1324^{\circ}C$ at conical tip of crucible. The light scattering phenomena occurred by internal cavities were controlled as decreasing the freezing rate to 2 mm/hr and/or as adopting the rotation of melt (7 rpm).

  • PDF

A Study on the Controller Design of Cooling System for LCD Panel Console (LCD 콘솔용 냉각장치의 제어기 설계에 관한 연구)

  • Choi, Kab-Yong;Oh, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3666-3672
    • /
    • 2010
  • This study dealt with the controller design of the cooling system for controlling the inside temperature of the LCD panel console(the rest console') using as an outdoor billboard. The cooling performance of the LCD console that had been developed by the preceding research, was insufficient in the performance of the controller. In order to improve the performance of the system, in this study defined the structure and the design condition of the system first, after measured the parameters having influence on the dynamic characteristics, and developed the mathematical model for the analysis of the system. Finally planned a controlling scheme of the system and simulated the controller for the performance checking, compared the performance of this system controller with the preceding one. The purpose of this study is the presentation of the more improving method for the system control.

Performances of Hot Gas Bypass Type Oil Cooler System (Hot Gas를 이용한 오일쿨러의 성능평가)

  • Lee, Seung-Woo;Yeom, Han-Kil;Park, Kil-Jong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-80
    • /
    • 2009
  • In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with machine tools. For precise temperature control, both cooling and heating should be implemented. A hot gas bypass type cooling cycle method has a simplified structure and temperature control accuracy to with in ${\pm}0.1^{\circ}C$. In this study, the performances of oil cooler system, including temperature controllability according to hot gas floe and preset temperature sustainability according to temperature load, were tested. It is expected that this study will contribute to the development and performances of oil cooler system, which could minimize thermal errors and improve the quality of precision machine tools.

Propellant Consumption Estimation of Reaction Control System During Flight of KSLV-II (한국형발사체 추력기 자세제어시스템 비행 중 추진제 소모량 추정식)

  • Kang, Shin-jae;Oh, Sang-gwan;Yoon, Won-jae;Min, Byeong-joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.529-536
    • /
    • 2020
  • Reaction Control System of the third stage of the Korean Space Launch Vehicle II conducts roll control and 3 axis control throughout third stage engine start, satellite separation, and collision and contamination avoidance maneuver. Reaction control system consumes its propellant in each thruster operation. Hence, loading of proper amount of the propellant is important for mission success. It is needed to have a rough estimation method of propellant consumption during the flight. In this paper, we developed a energy equation using pressure and temperature data which are acquired in the on-board reaction control system. We constructed a test system which is similar with the on-board reaction control system to verify the energy equation. Test results using deionized water were compared with estimated propellant consumption. We also conducted an error analysis of the energy equation. We also presented the propellant consumption result of a system level operation test.

A Study for Failure Examples of Emission Gas Recirculation and Air Control and Catalyzed Particulate Filter System in Diesel Engine Vehicle (디젤엔진 자동차의 EGR 및 공기 제어와 CPF 장치에 관련된 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Young Suk;Youm, Kwang Wook;You, Chang Bae;Kim, Sung Mo;Lim, Ha Young;Ahn, Ho Cheol;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.78-83
    • /
    • 2018
  • The purpose of this paper is to study for failure examples of emission gas recirculation and air control and catalyzed particulate filter system in diesel engine vehicle. The first example, the researcher found the fact that the much engine oil came into the intake manifold causing diaphragm damage of EGR valve. The engine oil entered into combustion chamber of engine so that a car emit the polluted exhaust gas when driving. The second example, the researcher certified the sticking phenomenon of carbon and foreign substance with the throttle flap so that the exhaust fumes discharged exhaust port. The third example, the regeneration function don't activated to not detect the temperature of exhaust gas because of damage in the sensor. Thus, the researcher must meticulously manage his car not in order to take place the problem of environmental pollution.

Mg-Al합금의 조성비율에 따른 발화온도특성

  • Han, U-Seop;Lee, Geun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.77-77
    • /
    • 2013
  • 최근의 산업활동에서는 신규 원료 개발과 생산 효율성을 높이기 위하여 분체 공정이 증가하고 있는데, 미세 분진의 취급으로 분진운의 형성과 착화가 용이해지므로 분진폭발이나 화재 위험성이 증가하고 있다. 분진을 안전하게 사용하고 저장, 취급하기 위해서는 착화 전의 위험성 지표로서 최저발화온도(MIT ; Minimum Ignition Temperature)를 사전에 파악해 두는 것이 중요하다. 분진농도의 발화온도는 장치 내의 발화위험성이나 분진 취급 공정의 사고예방대책 관리를 위한 실용적 관점에서 중요하게 활용되는 폭발특성값이다. 또한 분진의 발화온도는 분진농도에 의존하며 농도변화에 따른 가장 낮은 온도를 MIT라고 한다. 본 연구에서는 화재폭발사고 빈도가 줄지 않고 있는 Mg 및 Mg-Al합금(60:40 wt%, 50:50 wt%, 40:60 wt%)을 대상으로 조성비율에 따른 최저발화온도를 실험적으로 조사하였다. Mg 및 Mg-Al(60:40 wt%), Mg-Al(50:50 wt%), Mg-Al(40:60 wt%) 시료의 평균입경은 142, 160, 151, $152{\mu}m$이다. MIT실험장치는 IEC 61241-2-1(Methods for Determining the Minimum Ignition Temperatures of Dust, 1994)에 준거하여 제작하여 사용하였다. 실험장치는 가열로, 분진운 시료홀더, 온도조절장치, 압축공기 제어장치 등으로 구성되어 있다. 구체적인 실험방법은 시험분진를 분진홀더에 장착하고 0.5 bar의 압축공기를 0.3 sec 동안 사용하여 일정 온도로 가열된 로의 내부로 분진운을 부유시킬 때에 분진운이 발화하여 가열로 하단부의 개방구에까지 화염이 전파하는지를 디지털비데오카메라로 기록, 평가하여 발화 유무를 판정하였다. Mg합금에 대한 MIT를 측정한 결과 $740^{\circ}C$가 얻어졌으며, Mg-Al(60:40 wt%)의 MIT는 $820^{\circ}C$로 조사되었다. 그러나 Mg-Al(50:50 wt%) 및 Mg-Al(40:60 wt%)에 대해서는 최대 가열로의 설정온도를 $890^{\circ}C$까지로 하여 농도를 변화시키면서 조사하였으나 발화가 일어나지 않았다. 문헌에 따르면 Mg입자 표면의 산화피막은 다공성으로 일정 온도에서 산화반응이 시간에 따라 직선적으로 증가하는데 반하여, Al의 산화피막은 보호 작용을 하여 일정 온도에서 산화반응속도가 표면과 내부의 농도 기울기에 의한 확산속도에 의존한다고 보고하고 있다. 본 연구결과를 토대로 Mg-Al합금의 발화특성을 고찰해 보면, Mg-Al합금에서 자기 전파성이 작은 Al성분의 증가는 착화지연이 증가하여 연소성이 감소하여 최저발화온도의 증가로 이어지는 것으로 추정되었다. 또한 발화온도는 주어진 조건의 온도장에서 분진이 존재하는 시간 길이에 따라 변화하므로, 발화온도를 실험적으로 측정하는 경우에는 측정장치나 방법에 따라 달라지므로 사업장의 현장에 발화온도를 적용하는 경우에는 장치 내의 분진의 존재시간을 고려할 필요가 있다.

  • PDF