• Title/Summary/Keyword: 오일 오염도

Search Result 495, Processing Time 0.031 seconds

Ultrafiltration Treatment for Car Washing Effluent (한외여과막을 이용한 자동차 세척배수의 처리)

  • 장규만
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.202-208
    • /
    • 1999
  • The car washing effluent containing various oils and detergent was treated by ultrafiltration membranes. Dead-end type stirred cell (Amicon 8050) with 10, 30 and lOOk dalton membranes was used to determine permeation and rejection characteristics for the car washing effluent. In case of low molecular weight cut-off membranes, the effect of membrane fouling was weak under the applied pressures. However, the permeation flux for YM100 membrane(look dalton) may be affected by oil layer formation on the membrane surface as well as oil particle plugging for a part of membrane pores due to compressible and deformable oil properties. Oil and particle rejections in the permeates were over 95%, but detergent was passed easily through the membranes. Hence, the permeates containing detergent can be recycled to the system, and may reduce water pollution. Also, the car washing effluent was treated continuously by a capillary type ultrafiltration membrane of MWCO 50k dalton. The experimental data were fitted suitably to the cake filtration model.

  • PDF

Analysis of Total Aflatoxin, Ochratoxin A, Zearalenone, Deoxynivalenol and T-2 Toxin Contamination in Nuts (시중유통 견과류의 총아플라톡신, 오크라톡신 A, 제랄레논, 데옥시니발레놀, T-2 독소의 오염도 조사)

  • Hong, JoonBae;Park, Kun Taek
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.58-64
    • /
    • 2019
  • In the current study, 109 commercial nut samples were collected from different Korean markets and analyzed for the contamination of 5 different mycotoxins (aflatoxin, ochratoxin A, deoxynivalenol, zearalenone, and T-2 toxin) using ELISA kits. The results revealed that the most frequently detected mycotoxin was zearalenone (n=36, 33%), followed by aflatoxin (n=31, 28.4%) and ochratoxin A (n=30, 27.5%). Deoxynivalenol and T-2 toxin were also detected in 22 (20.3%) samples, respectively. Among 109 nut samples, 33 samples (30.3%) were contaminated only with one kind of mycotoxin, whereas 43 samples had at least 2 kinds of mycotoxins. Two samples were contaminated with as many as 4 different mycotoxins, and they were both walnuts. Although the monitoring results revealed the amount of aflatoxin contamination was under the safety criteria, there is no current safety guideline for other kinds of mycotoxins or multiple contaminations in Korea. Therefore, further studies should be performed to reveal the distribution of mycotoxin in different foods and propose appropriate safety guidelines for Korean markets.

A Sensitivity Analysis of the Meteorological Modeling through Objective Analysis in Gwangyang Area (광양만권역의 객관분석을 통한 기상장 모델링의 민감도 분석)

  • 이화운;원혜영;최현정;정우식;임헌호;김현구
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.431-432
    • /
    • 2003
  • 최근에 와서 연안에 위치한 공단지역과 대도시지역에서 배출된 대기오염물질들의 이류 및 확산에 대한 연구들이 많이 이루어짐에 따라 중규모 기상장 모델링에 관한 연구도 함께 이루어지고 있다(Pielke and Uliasz, 1998). 이런 지역의 오염도는 배출원과 오염물질의 종류 및 특성에 따라 좌우되지만, 그때의 기상 조건과 지형에도 큰 영향을 받는다. 그러므로 대기 오염 농도를 정확히 예측하기 위해서는 대기 오염 물질의 수송, 확산 및 침적에 큰 영향을 미치는 대기 유동장을 표현할 수 있는 수치 모델이 필요하다(오은주, 1995). (중략)

  • PDF

New Directions of Particulate Control Technology (새로운 집진기술 동향)

  • 김용진;정상현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.221-231
    • /
    • 1995
  • 산업발달에 따라 불가피하게 생성되며, 대기오염의 주종을 이루면서 인체에 가장 유해한 분진입자는 산업체의 오일(oil) 및 석탄연소 보일러, 자동차, 제철/제강 및 시멘트 플랜트 등으로 부터 배출되는 미세입자(fine particle)들이며, 앞으로 이들의 제어에 관한 연구가 지속적인 관심의 대상이 될 것이다. 한 예로, 석탄연소 화력발전소로부터 1$\mum$ 이하의 입자들의 배출량은 무게비로는 1% 이하이지만 입자수의 비율에서는99%를 차지하고 있다. 이들은 매우 높은 중금속 함유량을 지니고 있기 때문에 인체의 호흡시 심각한 문제를 유발시킬 뿐만 아니라, 이러한 미세입자들은 대기중에 부유하고 있다가 비(rain)에 의하여 세정되어 수질오염까지도 유발시킨다. 1992년 2월 공포된 대기환경보전법 시행규칙에 따라 분진배출 허용기준이 장기 입법예고 되므로서 1995년 1월과 1999년 1월의 2단계에 걸쳐 현재 적용 받고 있는 분진배출 규제치보다 훨씬 낮은 선진국 수준의 분진배출 규제가 요구되고 있으며, 분진이 배출되는 인근지역주민의 민원에 대처하기 위해서는 연돌로부터 분진배출이 눈에 감지되지 않을 정도까지 분진배출농도를 관리해야할 필요성이 높아지고 있다. 이에 따라 집진장치의 효율도 중유전소 Boiler 의 경우는 90% 이상, 석탄전소 Boiler의 경우는 99.5% 이상의 고효율이 요구되고 있다.

  • PDF