• Title/Summary/Keyword: 오염부지조사

Search Result 81, Processing Time 0.023 seconds

A case study of monitored natural attenuation at the petroleum hydrocarbon contaminated site: I. Site characterization (유류오염부지에서 자연저감기법 적용 사례연구: I. 부지특성 조사)

  • 윤정기;이민효;이석영;이진용;이강근
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.27-35
    • /
    • 2003
  • The study site located in an industrial complex has a Precambrian age gneiss as a bedrock. The poorly-developed, disturbed soils in the study site have loamy-textured surface soil (1 to 2 m) and gravelly sand alluvium subsurface (2 to 6 m) on the top of weathered gneiss bedrock. The depth of the groundwater table was about 3.5 m below ground surface and increased toward down-gradient of the site. The hydraulic conductivity of transmitted zone (gravelly coarse sand) was in the range of 5.0${\times}$10$\^$-2/∼1.85${\times}$10$\^$-1/ cm/sec. The fine sand layer was in the range of 1.5${\times}$10$\^$-3/ to 7.6${\times}$10$\^$-3/ cm/sec. and the reclaimed upper soil layer was less than 10$\^$-4/ cm/sec. Toluene, ethylbenzene, and xylene (TEX) was the major contaminant in the soil and groundwater. The average depth of the soil contamination was about 1.5 m in the gravelly sand alluvium layer. At the depth interval 2.4∼4.8 m, the highest contamination in the soil is located approximately 50 to 70 m from the suspected source areas. The concentration of TEX in the groundwater was highest in the suspected source area and a lesser concentration in the center and southwest parts of the site. The TEX distribution in the groundwater is associated with their distribution in the soil. Microbial isolation showed that Pseudomonas flurescence, Burkholderia cepacia, and Acinetobactor lwoffi were the dominant aerobic bacteria in the contaminated soils. The analytical results of the groundwater indicated that the concentrations of dissolved oxygen (DO), nitrate, and sulfate in the contaminated area were significantly lower than their concentrations in the none-contaminated control area. The results also indicated that groundwater at the contaminated area is under anaerobic condition and sulfate reduction is the predominant terminal electron accepting process. The total attenuation rate was 0.0017 day$\^$-1/ and the estimated first-order degradation rate constant (λ) was 0.0008 day$\^$-1/.

낙동강 강변여과수 개발부지 지하수 수질의 수직분포 특성

  • 현승규;우남칠;신우식
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.321-325
    • /
    • 2004
  • 국내 충적층의 철, 망간 문제는 지속적으로 지적되어오던 수질항목이다. 충적층 지하수 내 철과 망간의 용존 특성을 확인하고자 강변여과수 부지에서 지하수의 수리지화학적 특성을 조사하였다. Fe와 Mn에 의해 오염된 관정은 D-2와 DS-3로 모두 3월에 채취한 시료이며 NO$_3$-N는 모두 0 m/L 이다. NO$_3$-N에 대해 다른 관정은 2 mg/L NO$_3$-N를 넘고 있으며, DS-8와 DS-3에서 11.30과 20.2 mg/L NO$_3$-N의 값으로 먹는물 수질기준을 초과하고 있다. Mn에 대해 오염된 관정은 SJ-3이다. 10월에 채취한 시료에서 DS-2+l8 m에서 채취한 시료가 1.16 mg/L인 것을 제외하고 대부분의 시료가 2 mg/L를 초과하고 있고, DS-6+l3 m과 SJ-3+10 m에서 채취한 시료가 각각 10.71과 10.31 mg/L NO$_3$-N로 먹는물 수질기준을 초과하고 있다. DO 검층 자료와 NO$_3$-N 농도를 이용하여 Fe와 Mn이 먹는물 수질 기준을 초과하는 D-2와 DS-2 관정의 지하수 체의 혐기성 상태임을 확인하였다. 강변여과수 지역은 전반적으로 NO$_3$-N에 대해 인위적인 오염이 발생하고 있으며, 혐기성 상태 구간이 존재함에 따라서 Fe와 Mn이 먹는물 수질 기준을 초과하여 용존 상태로 존재한다.

  • PDF

An Assessment of Groundwater Pollution Potential of a Proposed Petrochemical Plant Site in Ulsan, South Korea Hydrogeologic and site characterization and groundwater pollution potential by utilizing several empirical assessment methodologies (지하수 오염 가능성 평가 -수리지질 및 부지특성 조사와 경험적 평가 방법을 이용한 지하수 요염 가능성-)

  • Han, Jeong Sang;Han, Kyu Sang;Lee, Yong Dong;Yoo, Dae Ho
    • Economic and Environmental Geology
    • /
    • v.23 no.4
    • /
    • pp.425-452
    • /
    • 1990
  • A tentative hydrogeologic and hydrodispersive study was carried out to evaluate the groundwater pollution potential at a selected site by utilizing empirical assessment methodologies in an advanced stage of quantitative computer aided assessment. The upper most aquifer is defind as saturated overburden and weathered zone including the upper part of highly fractured rock. Representative hydraulic conductivity and storativity of the uppermost aquifer are estimated at 2.88 E-6 m/s and 0.09, respectively. Also calculated Darcian and average linear velocity of groundwater along the major pathway are 0.011 m/d and 0.12 m/d with average hydraulic gradient of 4.6% in the site. The results of empirical assessment methodologies indicate that 1) DRASTIC depicts that the site is situated on non-sensitive and non-vulnerable area. 2) Legrand numerical rating system shows that the probability of contamination and degree of acceptability are classed to "Maybe-Improbable, and Probable Acceptable and Marginally Unacceptable" with situation grade of "B". 3)Waste soil-site interaction matrix assessment categorizes that the study site is located on "Class-8 Site".

  • PDF

Case Studies of Geophysical Mapping of Hazard and Contaminated Zones in Abandoned Mine Lands (폐광 부지의 재해 및 오염대 조사관련 물리탐사자료의 고찰)

  • Sim, Min-Sub;Ju, Hyeon-Tae;Kim, Kwan-Soo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.24 no.4
    • /
    • pp.525-534
    • /
    • 2014
  • Environmental problems typically occurring in abandoned mine lands (AML) include: contaminated and acidic surface water and groundwater; stockpiled waste rock and mill tailings; and ground subsidences due to mining operations. This study examines the effectiveness of various geophysical techniques for mapping potential hazard and contaminated zones. Four AML sites with sedimentation contamination problems, acid mine drainage (AMD) channels, ground subsidence, manmade liner leakage, and buried mine tailings, were selected to examine the applicability of various geophysical methods to the identification of the different types of mine hazards. Geophysical results were correlated to borehole data (core samples, well logs, tomographic profiles, etc.) and water sample data (pH, electrical conductivity (EC), and heavy metal contents). Zones of low electrical resistivity (ER) corresponded to areas contaminated by heavy metals, especially contamination by Cu, Pb, and Zn. The main pathways of AMD leachate were successfully mapped using ER methods (low anomaly peaks), self-potential (SP) curves (negative peaks), and ground penetrating radar (GPR) at shallow penetration depths. Mine cavities were well located based on composite interpretations of ER, seismic tomography, and well-log records; mine cavity locations were also observed in drill core data and using borehole image processing systems (BIPS). Damaged zones in buried manmade liners (used to block descending leachate) were precisely detected by ER mapping, and buried rock waste and tailings piles were characterized by low-velocity zones in seismic refraction data and high-resistivity zones in the ER data.

Characteristics of Groundwater Quality in a Riverbank Filtration Area (강변여과수 부지 내 충적층 지하수의 수질특성과 변화)

  • Hyun Seung-Gyu;Woo Nam-C.;Shin Woo-Sik;Hamm Se-Yeong
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.151-162
    • /
    • 2006
  • Characteristics and changes of groundwater qualify were investigated in a riverbank filtration area at Daesan-myeon, Changwon City, Korea. The total dissolved solids (TDS) in groundwater samples collected in October were much less than that in March, indicating the mixing with recharged water from precipitation, as well as the changes of dissolved oxygen profiles at monitoring wells from March to October. Redox processes at depths appeared to trigger Fe and Mn contamination of groundwater in riverbank deposits. Amorphous oxyhydroxides md carbonate minerals such as $MnCO_3$ were probably the reactive phases for dissolved Fe and Mn, respectively. Groundwater contamination by nitrate-nitrogen $(NO_3-N)$ was controlled by the redox processes and subsequent denitrification at the sampled depths. Distribution of $NO_3-N$ concentrations at monitoring wells suggested that the nitrate contaminants were originated from agricultural facilities on the riverbank deposits. Some of monitoring wells, DS-2, D-2, DS-3, SJ-1, and SJ-3, were only partially penetrated into the sand/gravel aquifer, and subsequently, could not fully function to detect the water quality changes for the pumping wells. Proper measures, with regulating agricultural activities in the riverbank deposits, should be carried out to prevent groundwater contamination of the riverbank filtration area.

Filter Clogging of Leachate Collection and Removal System at Waste Landfill (불량폐기물 매립지 및 주변토양 오염도에 관한 연구)

  • 김동우;한영수;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.310-313
    • /
    • 2000
  • 본 연구에서는 현재 사용 종료된 매립지 재사용을 위해 정비를 실시 중인 전국 매립지 중에서 충남 공주시 금홍동에 위치한 사용 종료된 매립지를 대상으로 하여 사업 지구 및 그 주변지역의 환경질 평가를 위하여 토양에 관한 오염도 조사를 실시하였다. 시료는 매립지 내 1개 지점과 주변 논 2개 지점, 밭 1지점으로 총 4개 지점에서 채취하였다. 토양시료의 분석항목은 토양환경보전법에서 제시하는 총 11개 항목으로 하였으며, 실험방법은 토양오염공정시힘방법에 준하여 실시하였다. 실험결과 토양환경보전법상 농경지에 대한 우려기준과 비교하여 전 항목이 기준에 크게 미치지 못하는 것으로 나타났다. 토양질의 면에서 된다면 이 매립지 부지는 일반적인 용도의 토지로써 사용이 가능하다고 사료된다.

  • PDF

A Study on Countermeasure and Contamination Analysis for Heavy Metal Pollution of Nearby Area using Stony Mountain Field Case (석산개발 사례를 이용한 주변 지역의 중금속 오염분석 및 대책방안에 관한 연구)

  • Han, Jung-Geun;Yoon, Won-Il;Lee, Yang-Kyu;Lee, Jong-Yuong;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.4
    • /
    • pp.57-66
    • /
    • 2010
  • This study is described in heavy metal pollution by the stony mountain development using field case. The heavy metal pollution is investigated for nearby area (soil and stream) of the developed stony mountain, and then the countermeasure using contamination analysis is suggested. The investigation result indicated that contamination of Sammak stream caused by the stone dust and leachate at the stony mountain development. Therefore, the heavy metal pollution is evaluated by using Pollution Index(PI). The evaluation results confirmed that the contaminated groundwater was the leading cause of the contamination in Sammak stream and nearby soil. Therefore, the Permeable Reaction Barrier(PRB), which has a environmentally-friendly reactant, should be applied to control a heavy metal of groundwater, and it will be a reasonable countermeasure.

  • PDF

Application of Geophysical Prospecting to Site Assessment of Waste Landfill (매립지 오염평가를 위한 물리탐사의 적용사례)

  • Lee, Cheol-Hyo;Park, Sam-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.104-121
    • /
    • 2001
  • Recently, the pollution of soil and groundwater becomes a serious social problem, and geophysical exploration methods have been introduced as a remedial investigation method of subsurface. Digital technologies such as personal computer have revolutionized our ability to acquire large volume of data in a short term, and to produce more reliable results for subsurface image. Also, color graphics easily visualizes the survey results in a more understandable manner, and it is widely used for not only characterizing the contaminated subsurface but also monitoring contaminant and remedial process. In this paper, electrical resistivity and electromagnetic (EM) surveys were carried out in order to understand characteristics of waste landfills, and the applicability of geophysical prospecting to site assessment of waste landfill was also tested. According to the result, electrical resistivity and electromagnetic (EM) surveys were effective in estimating distribution of the leachate plume.

  • PDF

A geophysical survey result over a hydrocarbon contaminated site (물리탐사를 이용한 국내 유류오염지역 조사 사례)

  • Song Yoonho;Park Sam Gyu;Seol Soon Jn;Choi Seong-Jun;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.122-140
    • /
    • 2001
  • We have applied the geophysical survey, mainly electric and electromagnetic (EM) methods, to a test site contaminated by hydrocarbon waste disposal and local spill. The multi-frequency, moving source & receiver EM survey along with ground penetrating radar (GPR) showed a fairly good performance in detection of buried metal pipes and objects. Magnetic survey measuring vertical and horizontal gradients were so sensitive to the small metallic objects spread over the surface that it's hard to discriminate the buried pipe. We chose electrical resistivity, EM and GPR survey to examine the soil contamination. Depth slices of resistivity distribution as the results of the inversion of resistivity and EM data coincided each other and closely matched the contaminated area determined by chemical analysis of the soil samples. GPR images did not show the reflection events related with contamination plume since there are no distinct spill in this site. We inferred the contamination using the penetration depth of the GPR energy, which could be used as auxiliary information to the resistivity and EM results. We summarized the applicability of each survey methods based on this results and proposed a desirable survey scheme for the determination of hydrocarbon contaminated site.

  • PDF