• Title/Summary/Keyword: 오염물질 부하량

Search Result 373, Processing Time 0.041 seconds

Assessment of Self-purification Capacity along the Midstream of Nakdong River (낙동강(洛東江) 중류수계(中流水系)의 자정능력(自淨能力) 평가(評價))

  • Choi, Eon-Ho;Lee, Su-Rae
    • Korean Journal of Environmental Agriculture
    • /
    • v.1 no.1
    • /
    • pp.39-47
    • /
    • 1982
  • Dissolved oxygen, BOD and flow pattern of the Nakdong River stream were measured for 3 years from 1978 to 1980 at quarterly intervals of January, April, June and October at 12 sites along the main stream from Sangju to Imhaejin and at 2 sites of Geumho and Nam River tributaries. With these data, the self-purification factors of the river were computed to obtain the following results: 1) The average BOD loads per day at the tributary of Geumho River were 94 tons in January, 39 tons in April, 60 tons in July and 54 tons in October, and these are considered to be the main source of water pollution toward the main stream of the Nakdong River. 2) Self-purification factors for the Hwawon-Hyunpung region of the main stream after receiving Geumho River water were computed to give $0.21{\sim}0.59$ of deoxygenation $constant(K_1)$ and $0.56{\sim}2.27$ of reaeration $constant(K_2)$. The oxygen-sag curves constructed for the main stream showed a remarkable decline at Hwawon and a quick recovery at Hyunpung, indicating a rapid decomposition of pollution loads received from the Geumho River. It was confirmed that the self-purification capacity of the Nakdong River was relatively high.

  • PDF

Estimate of Nitrous Oxide Emission Factors from Municipal Wastewater Treatment Plants (하수처리 공정별 아산화질소(N$_2$O) 배출계수 산정)

  • Yang, Hyung-Jae;Park, Jung-Min;Kim, Min-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1281-1286
    • /
    • 2008
  • Nitrous oxide(N$_2$O) is well known as a greenhouse gas that contributes to the global warming (310 times more per molecule than carbon dioxide) and to the destruction of the ozone layer. The objective of this study is to estimate N$_2$O emission factor using an emission isolation flux chamber from municipal wastewater treatment plants. N$_2$O gas was analysed by GC/ECD with 6 port gas sampling valve. The results of this study were as follows. N$_2$O emission factor of 5-Stage process from Y wastewater treatment plants was lowest as 0.94 g-N$_2$O/kg-TN. And that of other processes were 2.65 g-N$_2$O/kg-TN for Activated sludge process, 9.30 g-N$_2$O/kg-TN for Denipho process, and 26.73 g-N$_2$O/kg-TN for Sequencing Batch Reactor process. We have known that 5-Stage process is most appropriate process to reduce greenhouse for municipal wastewater treatment plants.

Applied Technologies and Effects for the Carbon Zero Office Building (업무용 탄소제로건물의 적용기술 및 효과)

  • Lee, Jae-Bum;Hong, Sung-Chul;Beak, Name-Choon;Choi, Jin-Young;Hong, You-Deog;Lee, Suk-Jo;Lee, Dong-won
    • Journal of Climate Change Research
    • /
    • v.2 no.4
    • /
    • pp.283-295
    • /
    • 2011
  • Many actions against climate change have been taken to reduce greenhouse gases (GHGs) emissions at home and abroad. As of 2007, the GHGs emitted from buildings accounted for about 23 % of Korea's total GHGs emission, which is the second largest GHG reduction potential following industry. In this study, we introduced Carbon Zero Building (CZB), which was constructed by the National Institute of Environmental Research to cut down GHGs from buildings in Korea, and evaluated the main applied technologies, the amount of energy load and reduced energy, and economic values for CZB to provide data that could be a basis in the future construction of this kind of carbon-neutral buildings. A total of 66 technologies were applied for this building in order to achieve carbon zero emissions. Applied technologies include 30 energy consumption reduction technologies, 18 energy efficiency technologies, and 5 eco-friendly technologies. Out of total annual energy load ($123.8kWh/m^2$), about 40% of energy load ($49kWh/m^2$) was reduced by using passive technologies such as super insulation and use of high efficiency equipments and the other 60% ($74.8kWh/m^2$) was reduced by using active technologies such as solar voltaic, solar thermal, and geothermal energy. The construction cost of CZB was 1.4 times higher than ordinary buildings. However, if active technologies are excluded, the construction cost is similar to that of ordinary buildings. It was estimated that we could save annually about 102 million won directly from energy saving and about 2.2 million won indirectly from additional saving by the reduction in GHGs and atmospheric pollutants. In terms of carbon, we could reduce 100 ton of $CO_2$ emissions per year. In our Life Cycle Cost (LCC) analysis, the Break Even Point (BEP) for the additional construction cost was estimated to be around 20.6 years.

Environmental Impacts Assessment of ITO (Indium Tin Oxide) Using Material Life Cycle Assessment (물질전과정평가(MLCA)를 통한 투명전극 ITO (Indium Tin Oxide)의 환경성 평가)

  • Lee, Soo-Sun;Lee, Na-Ri;Kim, Kyeong-Il;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2012
  • In this study, we executed an environmental impact assessment about recycling of ITO (Indium Tin Oxide), used for touch panel. ITO is mainly used to make transparent conductive coatings for touch and flat screen LCD (Liquid Crystal Display), ELD (Emitting Light Device), PDP (Plasma Display Panel). This demand is increasing little by little. but form current status, ITO is discarded than recycling. It is important to recycling ITO for national strategies about resource conservation, and reduce environmental burden. Also Landfill or incineration of ITO cloud be harmful to the human health in the long-term. Material Life Cycle Assessment method (MLCA) was conducted for comparison landfill and recycling of ITO. MLCA would provide more information for environmental issues and potential environmental impacts of ITO. The study includes two scenarios, the basic scenario is recycling of ITO (10, 20, 30%) and the other scenario is landfill of ITO. In addition, amount of carbon dioxide and energy were calculated.

Development of GIS based Water Quality Simulation System for Han River and Kyeonggi Bay Area (한강과 경기만 지역 GIS 기반 통합수질모의 시스템 개발)

  • Lee, Chol-Young;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.4
    • /
    • pp.77-88
    • /
    • 2008
  • There has been growing demands to manage the water quality of west coastal region due to the large scale urbanization along the coastal zone, the possibility of application of TMDL(Total Maximum Daily Loadings) to Han river, and the natural disaster such as oil spill incident in Taean, Chungnam. However, no system has been developed for such purposes. In this background, the demand of GIS based effective water quality management has been increased to monitor water quality environment and propose best management alternatives for Han river and Kyeonggi bay. This study mainly focused on the development of integrated water quality management system for Han river bas in and its estuary are a connected to Kyeonggi bay to support integrated water quality management and its plan. Integration was made based on GIS by spatial linking between water quality attributes and location information. A GIS DB was built to estimate the amount of generated and discharged water pollutants according to TMDL technical guide and it included input data to use two different water quality models--W ASP7 for Han river and EFDC for coastal area--to forecast water quality and to suggest BMP(Best management Practices). The results of BOD, TN, and TP from WASP7 were used as the input to run EFDC. Based on the study results, some critical areas which have relatively higher pollutant loadings were identified, and it was also identified that the locations discharging water pollutant loadings to river and seasonal factor affected water quality. And the relationship of water quality between river and its estuary area was quantitatively verified. The results showed that GIS based integrated system could be used as a tool for estimating status-quo of water quality and proposing economically effective BMPs to mitigate water pollution. Further studies need to be made for improving system's capabilities such as adding decision making function as well as cost-benefit analysis, etc. Also, the concrete methodology for water quality management using the system need to be developed.

  • PDF

Characteristics of Water Environment on Manun Reservoir (중산간 농업용 만운저수지의 수질환경특성)

  • Nam, Gui-Sook;Jang, Jeong-Ryeol;Lee, Gwang-Sik;Yoon, Keung-Sup;Lee, Sang-Joon
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.1
    • /
    • pp.16-25
    • /
    • 2003
  • Manun Reservoir, located in Andong district has the capacity of 2 million tons in irrigation water supply with the drainage area of $23.8\;km^2$. Manun Reservoir is over fifty year old, and shallow in depth. The ratio of drainage area (DA) to reservoir surface area (SA) as an effective physical parameter on water quality was 56.1 and was higher than those of other agricultural reservoirs. The ratio of reservoir storage (ST) to SA in Manun Reservoir was 4.79, and the mean depth was below 8m. Both ratios of DS/SA, total area (TA)/ST and ST/SA in Manun Reservoir were relatively higher than those in other agricultural reservoir and natural lakes in Korea. These physical parameters in Manun Reservoir, however, had a eutropic potential significance. Average of COD, IN, and TP in Manun Reservoir were 11.1 mg/L 1.426 mg/L, 0.093 mg/L, respectively. In the inflow stream of Manun Reservoir, the TN ($1.426{\sim}3.809\;mg/L$) was higher than those in reservoir. Only Lyngbya spp. was dominant in phytoplankton for this study period and Gymnodinium spp., Peridinium spp., and Cryptomonas spp. were dominant in zooplankton. According to the Carlson's trophic status index, Mnnun Reservoir was eutrophic in 1996, 1997, and 1999, and hypertrophic in 1998.

Dynamic Network Loading Model based on Moving Cell Theory (Moving Cell Theory를 이용한 동적 교통망 부하 모형의 개발)

  • 김현명
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.113-130
    • /
    • 2002
  • In this paper, we developed DNL(Dynamic Network Loading) model based on Moving cell theory to analyze the dynamic characteristics of traffic flow in congested network. In this paper vehicles entered into link at same interval would construct one cell, and the cells moved according to Cell following rule. In the past researches relating to DNL model a continuous single link is separated into two sections such as running section and queuing section to describe physical queue so that various dynamic states generated in real link are only simplified by running and queuing state. However, the approach has some difficulties in simulating various dynamic flow characteristics. To overcome these problems, we present Moving cell theory which is developed by combining Car following theory and Lagrangian method mainly using for the analysis of air pollutants dispersion. In Moving cell theory platoons are represented by cells and each cell is processed by Cell following theory. This type of simulation model is firstly presented by Cremer et al(1999). However they did not develop merging and diverging model because their model was applied to basic freeway section. Moreover they set the number of vehicles which can be included in one cell in one interval so this formulation cant apply to signalized intersection in urban network. To solve these difficulties we develop new approach using Moving cell theory and simulate traffic flow dynamics continuously by movement and state transition of the cells. The developed model are played on simple network including merging and diverging section and it shows improved abilities to describe flow dynamics comparing past DNL models.

Cluster and Factor Analyses Using Water Quality Data in the Sapkyo Reservoir Watershed (삽교호유역의 수질자료를 이용한 군집분석 및 요인분석)

  • Im, Chang-Su;Sin, Jae-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.149-159
    • /
    • 2002
  • The monthly water quality data measured at 19 stations located in the Sapkyo reservoir watershed were clustered into 2 to 7 clusters and factor analysis was conducted to characterize the water quality, using the information obtained from cluster analysis. The result of cluster analysis shows that Sapkyo reservoir and each stream (Sapkyo stream, Muhan stream and Kokkyo stream) in Sapkyo reservoir watershed hove their own water quality characteristics. The result of water quality analysis indicates that the concentration of suspended solids from Sapkyo reservoir is much higher than those of other streams, and which is probably because of increment of phytoplankton biomass with rich nutrient flowing Into Sapkyo reservoir from the upper stream of watershed. Furthermore, the concentrations of biochemical oxygen demand and chemical oxygen demand were 3.5 to 4.8 times and 1.7 to 2.5 times those of other streams, respectively. The overall water quality of Sapkyo reservoir watershed was considered to exceed eutrophic condition. Based on factor analysis, the water quality characteristics of Sapkyo stream and Muhan stream were closely related with farm land and residence. The water quality of Kokkyo stream was influenced by superabundant organic matter flowing from Chonan city and district wastewater treatment plant located in the upper stream of Kokkyo stream. The water quality factor influencing Sapkyo reservoir was closely related with water quality factors of other three streams.

Analysis of Fish Ecology and Water Quality for Health Assessments of Geum - River Watershed (금강본류의 건강성 평가를 위한 어류생태 및 수질 특성분석)

  • Park, Yun-Jeong;Lee, Sang-Jae;An, Kwang Guk
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.2
    • /
    • pp.187-201
    • /
    • 2019
  • This study examined the physicochemical water quality and evaluated the ecological health in 14 sites of Geum River (upstream, mid-stream, and downstream) using the fish community distribution and guilds and eight multi-variable matrices of FAI (Fish Assessment Index) during June 2008-May 2009. The analysis of the water quality variables showed no significant variation in the upstream and mid-stream but a sharp variation due to the accumulation of organic matter from the point where the treated water of Gap and Miho streams flew. The analysis of physicochemical water properties showed that BOD, COD, TN, TP, Cond, and Chl-a tended to increase while DO decreased to cause eutrophication and algae development from the downstream where Miho and Gap stream merged. The analysis of fish community showed that the species richness index and species diversity index increased in the mid-stream area but decreased in the downstream area, indicating the stable ecosystem in the upper stream and the relatively unstable ecosystem in the downstream. The analysis of the species distribution showed that the dominant species were Zacco platypus that accounted for 20.9% of all fish species and Zacco koreanus that accounted for 13.1%. The analysis of the fish tolerance and feeding guild characteristics showed that the sensitive species, the insectivore species, and the aquatic species were dominant in the mid-stream point. On the other hand, contaminants from the sewage water treatment plant of Miho stream had a profound effect in the downstream to show the dominance of tolerant species, omnivorous species, and lentic species. Therefore, it is necessary to improve water quality by reducing the load of urban pollutants and to pay attention to the conservation and restoration of aquatic ecosystems.

Experimental Study on Energy Saving through FAN Airflow Control in the Generator Room of a 9200-ton Training Ship (9200톤급 실습선 발전기실 FAN 송풍유량 제어를 통한 선박에너지 절약에 관한 실험적 연구)

  • Moon-seok Choi;Chang-min Lee;Su-jeong Choe;Jae-jung Hur;Jae-Hyuk Choi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.697-703
    • /
    • 2023
  • As a part of the global industrial efforts to reduce environmental pollution owing to air pollution, regulations have been established by the International Maritime Organization (IMO). The IMO has implemented various regulations such as EEXI, EEDI, and CII to reduce air pollution emissions from ships. They are also promoting measures to decrease the power consumption in ships, aiming to conserve energy. Most of the power used in ships is consumed by electric motors. Among the motors installed on ships, the engine room blower that takes up a significant load, operates at a constant irrespective of demand. Therefore, energy savings can be expected through frequency control. In this study, we demonstrated the efficacy of energy savings by controlling the frequency of the electric motor of the generator blower that supplies combustion air to the generator's turbocharger. The system was modeled based on the output data of the turboharger outlet temperature in response to the blower frequency inpu. A PI control system was established to control the frequency with the target being the turbocharger outlet temperature. By maintaining the turbocharger design standard outlet temperature and controlling the blower frequency, we achieved an annual energy saving of 15,552kW in power consumption. The effectiveness of energy savings through frequency control of blower fans was verified during the summer (April to September) and winter (March to October) periods. Based on this, we achieved annual fuel cost savings of 6,091 thousand won and reduction of 8.5 tons of carbon dioxide, 2.4 kg of SOx, and 7.8 kg of NOx air pollutants on the training ship.