• 제목/요약/키워드: 예상온열감

검색결과 44건 처리시간 0.019초

하계 인공환경실험에서의 온열쾌적특성 (Characteristics of thermal comfort for artificial environment experiment in summer)

  • 박종일;김경훈;홍희기;민병일;김창주
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

PMV 지표에 의한 개별 공조시스템(PACS)의 쾌적성 평가에 관한 연구 (Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) b PMV Index)

  • 최익순;정광섭;박영칠;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.647-652
    • /
    • 2001
  • The thermal comfort of indoor spaces is very important factor in our life. Regions, cultures, climates and individual difference for establishing thermally comfortable environments should be considered carefully because these factors have a large influence on the thermal comfort doing some complicated interactions with environmental, psychological and physical elements. Recently, predicted mean vote(PMV) based on the heat transfer theory between environmental factors and human bodies has evaluated by many researchers and widely used nowadays. The objective of this study is to evaluate the thermal comfort in workspaces with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupant's thermal senses with response to the environment.

  • PDF

개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS))

  • 최익순;정광섭;박영철;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

여름철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer)

  • 이철희;배귀남;최항철;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

겨울철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Winter)

  • 배귀남;이철희;이춘식;최항철
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.310-318
    • /
    • 1995
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 138 occupants were questioned to evaluate Korean thermal comfort in office building in winter. Thermal sensation was estimated by using PMV(Predicted Mean Vote) and ET*(New Effective Temperature) indices. Comparing present experimental result with international standards and that of other research, Korean thermal responses were discussed. Seasonal difference between summer and winter was also discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained; TSV=0.432ET*-8.814 and neutral temperature is $20.4^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $19.4{\sim}22.4^{\circ}C$.

  • PDF

동계 인공환경실험에 의한 온열쾌적특성 연구 (A study on characteristics of thermal comfort for artificial environmental experiment in winter)

  • 박종일;김경훈;정성일
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF

유형별 녹지 시뮬레이션을 통한 아파트 단지 내 도시열섬현상 저감효과 분석 (Simulation Analysis of Urban Heat Island Mitigation of Green Area Types in Apartment Complexes)

  • 지은주;김다빈;김유경;이정아
    • 한국조경학회지
    • /
    • 제51권3호
    • /
    • pp.153-165
    • /
    • 2023
  • 도시 열섬현상을 완화하기 위하여 본 연구는 아파트 단지 내 바람의 흐름과 열쾌적성을 고려하여 녹지 연결성을 향상시키기 위한 효과적인 녹지 계획 시나리오를 제안하는 것에 있다. 연구의 사례 대상지는 서울특별시를 대상으로 2020년 6월부터 8월까지 수집된 온도 및 불쾌지수 자료를 비교하여 강동구 고덕동에 위치한 아파트 단지로 선정하였다. 먼저, 연구대상지 현재의 열환경과 바람환경을 분석하였다. 이를 바탕으로 녹지의 패치와 코리도 형태의 요소를 고려하여 시나리오 1(패치), 시나리오 2(코리도), 시나리오 3(패치+ 코리도)의 세 가지 시나리오를 계획하였다. 이후, 각각의 시나리오별 풍속, 풍향, 그리고 열쾌적성을 ENVI-met로 분석하여 도시 열섬현상의 완화효과를 비교하였다. 연구의 결과, 패치 형태의 녹지는 풍속의 증가 및 풍량 개선에 기여하여 예상온열감(PMV)가 31.20% 감소하는 효과를 보였으며(시나리오 1), 열쾌적성 지표(PET)가 68.59%감소하는 것으로 나타났다. 반면 코리도 형태의 녹지로 계획한 경우 바람길의 연결이 용이하여 패치 형태의 녹지 계획에 비하여 풍속이 더욱 높아지는 결과가 나타나 예상온열감(PMV)은 92.47%, 열쾌적성 지표(PET)는 90.14% 감소하였다 (시나리오 2). 녹지 패치와 녹지 코리도를 복합적으로 계획한 경우 가장 큰 풍속의 증가와 연결성을 보여 예상온열감(PMV)에서 95.75%, 열쾌적성 지표(PET)에서 95.35% 감소하는 것으로 나타났다(시나리오 3). 그러나 대상지 내에서 협소한 지역의 경우 패치형 녹지계획이 코리도형의 녹지 계획에 비하여 열쾌적성을 개선하는 데에 더 효과적으로 나타났다. 따라서, 연구의 결과에 근거하여 도시열섬현상을 효과적으로 완화하기 위해서는 패치형태의 녹지와 코리도 형태의 녹지의 계획의 복합적인 형태로 계획될 수 있도록 제안하고자 한다. 본 연구의 결과는 향후 도시형 아파트단지의 도시열섬현상 완화를 위한 녹지계획의 가이드를 제시하여 도시열섬현상에 따른 회복력을 향상시키기 위한 기초자료를 제시할 수 있을 것이다.

공조방식에 의한 예상 온열감 반응(PMV) 변화에 따른 심리/생리적 감성반응의 변화 (The Changes of Psychological and Physiological Emotional Responses According to Change of the Index of Predicted Mean Vote (PMV) due to Air Conditioning Types)

  • 김보성;민윤기;민병찬;김진호
    • 감성과학
    • /
    • 제14권4호
    • /
    • pp.645-652
    • /
    • 2011
  • 본 연구는 냉 난방공조 조건에서 예상 온열감 반응(predicted mean vote; PMV)의 변화에 따른 심리 생리적 감성반응의 변화를 살펴보고자 하였다. 이를 위해 기존 공조 시스템의 냉 난방 가동에 따라 PMV의 변화를 유도하고, 쾌/불쾌 및 각성/이완 정도를 심리적 감성반응으로, 심박률(heart rate; HR)을 생리적 감성반응으로 활용하여 PMV 변화에 따른 심리 생리적 감성반응을 측정하였다. 그 결과, 동일한 PMV 변화 범위 내에서 재실자의 심리적 쾌/불쾌 및 긴장/이완 반응과 생리적 반응이 공조 조건이 달라짐에 따라 변화하는 것으로 나타났다. 이러한 결과는 난방과 냉방의 공조조건에 따라 재실자의 실내 온열환경에 대한 감성반응이 서로 다를 뿐 아니라 각 공조 조건에 민감한 감성반응이 존재하는 것으로 해석할 수 있다. 이는 실내 온열조건을 재실자에게 가장 적합하도록 조절하고자 할 때, 인간의 심리 및 생리적 감성반응을 모두 고려해야 할 필요가 있음을 시사한다.

  • PDF

저상버스 탑승객의 온열 쾌적성에 관한 수치연구 (Numerical Study on Human Thermal Comfort in a Low Floor Bus)

  • 박원구;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.645-651
    • /
    • 2015
  • Numerical study on human thermal comfort in a low floor bus has been conducted. Human thermal comfort in a bus depends mainly on air temperature, air velocity, mean radiant temperature, humidity, and direct solar flux, as well as the level of activity and thermal properties of clothing. The paper presents the velocity and temperature distribution, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) indices for the driver and passengers.