• Title/Summary/Keyword: 옆벽

Search Result 6, Processing Time 0.065 seconds

The characteristics and optimization of submicron optical mask using electromagnetic scattering effect (전자기파 산란을 이용한 Submicron 광학 MASK의 특성 및 최적화)

  • 최준규;박정보;김유석;이성묵
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.345-352
    • /
    • 1997
  • Recently, in designing optical mask such as 4GDRAM, the scattering effect of electromagnetic wave must be considered. For this reason we claculated directly the mask function using the finite difference time domain(FDTD) method. The modification of image theory with this new mask function could explain clearly the scattering effect at the etched side wall of the submicron optical mask. The characteristics of the various type of alternating PSM were investigated. According to the simulation, the dual wet etch process was the most useful fabrication technique to overcoe the light scattering off at the shifted opening.

  • PDF

A Study on the Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J. W.;Kim, J. H.;Kim, K. Y.;Kim, Y. T.;Lee, Y. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

A PIV Measurement on Flow Characteristics of Intakes within a Sump in a Pump Station (펌프장의 흡입수조내 흡입관의 유동특성에 관한 PIV 측정)

  • Lee, Yeong-Ho;Kim, Yu-Taek;Kim, Jeong-Hwan;Choe, Jong-Ung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.209-215
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the Pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

Study on Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J.W.;Kim, J.H.;Nam, Cheong-Do;Kim, Y.T.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.563-569
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

Transient Analysis of Pressure Behavior of Cryogenics in Closed Vessel (극저온 저장용기의 내부압력 거동에 대한 비정상해석)

  • 강권호;김길정;박영무
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • Self-pressurization of cylindrical container of cryogen is numerically analyzed. The container is axi-symmetric and heated from side wall with constant heat flux. Natural convection by external heat flux is studied numerically using finite difference method. Oxygen, nytrogen and hydrogen are working fluids in this paper. Liquid is considered incompressible fluid and vapor is assumed to behave as gas meeting with virial equation of gas. The Second virial coefficients of gas are obtained from Lennard-jones model. The important variables which have effects on self-pressurization are external heat flux, heat capacity of wall and initial ullage in container. The most important variable of them is external heat flux. The pressure rise calculated from the virial gas model is slightly different from that calculated using Ideal gas model for oxygen.

  • PDF

Flux correction coefficient in numerical simulation of shallow-water flow over square-edged broad-crested weir (직각 광정 위어를 지나는 천수 흐름 모의에서 흐름률 보정 계수)

  • Seung-Yong Hwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.503-503
    • /
    • 2023
  • Hwang(2022; J.KWRA, 55, 10)은 수심 적분 모형으로 불연속 지형을 경사로 완화하지 않고 직접 해석하는 Hwang(2015; J.KSCE, 35, 6)의 기법이 적용된 수치 모형의 정확도를 높이기 위해 지형 전면에 실제로 작용하는 정수압 분포와 차이를 해명하는 흐름률 보정 계수(flux correction coefficient)를 도입하였다. 직각 광정 위어 실험 중에서 널리 알려진 다섯 가지 월류 실험으로부터 218회의 시행을 추려 실험과 모의에서 월류량 값이 서로 잘 일치하는 흐름률 보정 계수를 각각 산정하였는데, 이때 광정 위어를 지나는 흐름을 모의하기 위해 계산 영역을 평면 2차원으로 두고 삼각형 계산 격자로 분할하였다(Hwang, 2022). 실험에 사용된 실험 수로들이 수로의 길이 방향으로 그 폭이 일정하므로 옆벽의 영향이 크지 않다면 수로의 단위 폭에 모형을 적용함으로써 계산 영역의 차원을 한 수준 낮출 수 있다. 실질적으로 1차원 모의가 되어 모의 시간을 획기적으로 줄일 수 있으므로 다양한 분석이 가능하겠으나, 2차원 모의로부터 결정된 흐름률 보정 계수를 수정없이 그대로 적용하는 것이 적절한지 검토할 필요가 있다. 이 연구에서는 Hwang(2022)이 검토한 218회의 직각 광정 위어 실험 시행에 수로의 단위 폭에 불연속 지형을 직접 해석할 수 있는 Hwang(2015)의 1차원 모형을 적용하고 모의와 실험에서 월류량의 차이가 최소가 되는 흐름률 보정 계수를 각각 산정하였다. 결정된 흐름률 보정 계수의 평균값을 별도로 선정된 두 가지 직각 광정 위어 실험에 적용하였으며, 보정에 따른 모형의 성능을 평가하기 위해 Willmott의 일치 지표(index of agreement)를 이용하였다. 흐름률 보정 계수를 적용하였을 때, 한 실험 경우에 대해 모형의 성능이 대폭 개선됨을 확인하였고 성능 개선이 미미한 나머지 실험 경우는 보정 전에 일치 지표가 이미 상당히 높은 편이었다. 2차원 문제에 이어 1차원 모형의 적용에서도 흐름률 보정 계수를 결정함으로써 계단이나 직립 보와 같은 불연속 지형을 넘나드는 천수 흐름의 월류량을 더 쉽고 정확하게 파악할 수 있을 것으로 기대된다.

  • PDF