• Title/Summary/Keyword: 영상 질의

Search Result 1,492, Processing Time 0.028 seconds

Investigation of Measurement Feasibility of Large-size Wastes Based on Unmanned Aerial System (UAS 기반 대형 폐기물 발생량 측정 가능성 모색)

  • Son, Seung Woo;Yu, Jae Jin;Jeon, Hyung Jin;Lim, Seong Ha;Kang, Young Eun;Yoon, Jeong Ho
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.809-820
    • /
    • 2017
  • Efficient management of large-size wastes generated from disasters etc. is always in demand. Large-size wastes are closely connected to the environment, producing adverse effects on the air quality, water quality, living environment and so on. When large-size wastes are generated, we must be able to estimate the generated amount in order to transfer them to a temporary trans-shipment site, or to properly treat them. Currently, we estimate the amount of generated large-size wastes by using satellite images or unit measure for wastes; however, the accuracy of such estimations have been constantly questioned. Therefore, the present study was performed to establish three-dimensional spatial information based on UAS, to measure the amount of waste, and to evaluate the accuracy of the measurement. A measurement was made at a waste site by using UAS, and the X, Y, Z RMSE values of the three-dimensional spatial information were found to be 0.022 m, 0.023 m, and 0.14 m, all of which show relatively high accuracy. The amount of waste measured using these values was computed to be approximately $4,273,400m^3$. In addition, the amount of waste at the same site was measured by using Terrestrial LiDAR, which is used for the precise measurement of geographical features, cultural properties and the like. The resulting value was $4,274,188m^3$, which is not significantly different from the amount of waste computed by using UAS. Thus, the possibility of measuring the amount of waste using UAS was confirmed, and UAS-based measurement is believed to be useful for environmental control with respect to disaster wastes, large-size wastes, and the like.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

Chronic Kidney Disease-mineral Bone Disorder and Active Vitamin D Analogs for Treating Severe Hyperparathyroidism in Children Receiving Chronic Peritoneal Dialysis (소아복막투석환자에서 CKD-MBD와 중증 부갑상샘 기능항진증에서 비타민 D 치료)

  • Kang, Eun Gu;Lee, Joo Hoon;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.18 no.2
    • /
    • pp.64-70
    • /
    • 2014
  • Purpose: The aims of this study were to assess the clinical and laboratory profiles of chronic kidney disease-mineral bone disorder (CKD-MBD) and to assess the effects of treatment of active vitamin D analogs on severe hyperparathyroidism (SHPT) in pediatric patients on chronic peritoneal dialysis. Methods: This is a retrospective study included 53 patients who had been undergoing dialysis for more than 1 year, between January 2003 and December 2012. Results: Even after treatment with phosphate binders and active vitamin D analogs, the $mean{\pm}standard$ deviation of the percentage of time during peritoneal dialysis that the patients' serum concentrations of phosphorus, corrected total calcium, and parathyroid hormone (PTH) fell within the Kidney Disease Outcomes Quality Initiative recommended ranges was $25.06{\pm}17.47%$, $53.30{\pm}23.03%$, and $11.52{\pm}9.51%$, respectively. Clinical symptoms or radiological signs of CKD-MBD were observed in 10 patients (18.9%). There were significant differences in percentage of time that the serum intact PTH concentration was outside of the recommended range between patients with and without symptoms or signs of CKD-MBD (below recommended range, $11.74{\pm}7.37%$ vs. $40.77{\pm}25.39%$, P <0.001; above the recommended range, $63.79{\pm}27.86%$ vs. $37.09{\pm}27.76%$, P =0.022). Of the 25 patients with SHPT, high-dose alfacalcidol treatment was required in 13 patients that controlled SHPT in 7 of these patients, without marked complications. Conclusion: Despite our efforts to manage CKD-MBD, patients' met the recommended ranges from relevant guidelines at a low frequency. The treatment of high-dose active vitamin D analogs was required in about half of the patients with SHPT and effective in about half of them.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Assessment of Pollutant Loads from Alpine Agricultural Practices in Nakdong River Basin (낙동강 수계 고령지 밭의 비점오염 물질 유출 특성 조사 및 단위 유출량 산정)

  • Joo, Jin-Ho;Yang, Jae-E.;Ok, Yong-Sik;Oh, Sang-Eun;Yoo, Kyung-Yeol;Yang, Su-Chan;Jung, Yeong-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.3
    • /
    • pp.233-238
    • /
    • 2007
  • To assess pollutant loads in Nakdong river from highland agriculture in Kyungbuk province we. analyzed water qualities such as BOD, COD, T-N, T-P and SS in year 2005. BOD values in rainy period (June and July) were relatively higher than those in dry period, and those in 4 sites among 17 sites ranged from 10.71-19.25 mg/L which exceeded water criteria (8 mg/L) for agricultural use. COD values showed similar trends like BOD values. These trends might be caused by outflow of nutrients applied in agricultural lands. T-N content ranged from 0.1 to 14 mg/L. Those in lower reaches of stream were greater in those in upper stream. Compared to T-N contents during non-farming season, T-N content in farming season were higher. These phenomenon could be due to continuous input of nutrients from small watercourses. Averaged T-P content in lower stream during farming season was 0.4 mg/L, which was eight times higher than the limiting level for algae occurrence (0.05 mg/L). BOD, T-P, T-N loads from alpine agricultural practices were 12.25 $kg/km^2{\cdot}day$, 0.55 $kg/km^2{\cdot}day$ and 32.35 $kg/km^2{\cdot}day$, respectively. These values were greater than those from forestry. Therefore, Best management Practices (BMP) for alpine agricultural field are needed to reduce pollutant loads in Nakdong river.

Design of Translator for generating Secure Java Bytecode from Thread code of Multithreaded Models (다중스레드 모델의 스레드 코드를 안전한 자바 바이트코드로 변환하기 위한 번역기 설계)

  • 김기태;유원희
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.148-155
    • /
    • 2002
  • Multithreaded models improve the efficiency of parallel systems by combining inner parallelism, asynchronous data availability and the locality of von Neumann model. This model executes thread code which is generated by compiler and of which quality is given by the method of generation. But multithreaded models have the demerit that execution model is restricted to a specific platform. On the contrary, Java has the platform independency, so if we can translate from threads code to Java bytecode, we can use the advantages of multithreaded models in many platforms. Java executes Java bytecode which is intermediate language format for Java virtual machine. Java bytecode plays a role of an intermediate language in translator and Java virtual machine work as back-end in translator. But, Java bytecode which is translated from multithreaded models have the demerit that it is not secure. This paper, multhithread code whose feature of platform independent can execute in java virtual machine. We design and implement translator which translate from thread code of multithreaded code to Java bytecode and which check secure problems from Java bytecode.

  • PDF

Multinational Corporate Linkage Stability in the Canadian Urban System (캐나다 도시체계에서의 다국적기업 연계패턴의 안정성)

  • Kee-Bom Nahm
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.151-172
    • /
    • 1998
  • Over the past two decades, the process of globalization of multinational corporations has increased at a rapid rate. One manifestation of this process is the establishment of corporate head offices in a variety of international centers to administer and coordinate, the day-to-day operations in the host countries. In establishing a subsidiary overseas a firm creates a direct link between the operations of the domestic corporate center and the foreign host center This paper investigates elements of stability and change in the international linkage patterns among domestic parent corporations and host subsidiaries over the past several decades. In particular, it seeks answers to a number of question related to stability and change in linkages among foreign centers of control and those Canadian centers selected to administer the subsidiary operations from 1970 to 1991 over the four primary sectors, namely, resources, manufacturing, services, and finance. By confirming the core stability and dispersed linkages hypotheses, the papar offers some generalizations with respect to the location and stability of subsidiary headquarters centers in Canada and their respective subsector specialties. Finally, it addresses further research avenues fer the quaternary place study.

  • PDF

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN (유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구)

  • Park, Heon-Jeong;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.419-430
    • /
    • 2000
  • The purpose of this study was to compare the microleakage pattern of preventive resin restoration using conventional composite resin and flowable composite resin that recently developed. 60 sound premolar teeth were allocated to three groups. Flowable composite resin was used for the experimental groups(Group I and II) and conventional resin for the control group(Group III). After composite filling and sealant application, all teeth were thermocycled and evaluated for microleakage under light microscope. Additionally, a variety of voids formed inside restorations were also evaluated. Data were analyzed statistically using Kruskal-Wallis test and/or Mann-Whitney U-test. The results of the present study were as follows. 1. Microleakage found in all samples was only limited to the interface of restoration margin and enamel. 2. The flowable composite resin groups (Group I, II) generally showed less microleakage than control groups (conventional preventive resin restoration) (p<0.05) 3. Various types of voids were observed in most specimens. Especially, there was a tendency for more and larger voids to be found in group I, II than group III (p<0.05).

  • PDF

Synthesis and Evaluation of $2-[^{18}F]Fluoro-A85380$, a Radioligand for ${\alpha}_4{\beta}_2$ Nicotinic Acetylcholine Receptor Imaging (${\alpha}_4{\beta}_2$ 니코틴성 아세틸콜린 수용체 영상 방사성리간드 $2-[^{18}F]fluoro-A85380$의 합성 및 평가)

  • Ryu, Eun-Kyoung;Choe, Yearn-Seong;Kim, Sang-Eun;Hwang, Sae-Hwan;Paik, Jin-Young;Choi, Yong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.261-270
    • /
    • 2002
  • Purpose: Nicotinic acetylcholine receptors (nAChRs), which mediate excitatory neurotransmission, are known to participate in various neurophysiological functions. Severe losses of nAChRs have been noted in Alzheimer's and Parkinson's diseases. Therefore, noninvasive and quantitative imaging of nAChRs would offer a better understanding on the function of these receptors. In this study, $2-[^{18}F]fluoro-A85380\;([^{18}F]1)$, an ${\alpha}_4{\beta}_2$ nAChRs radioligand, was prepared using one HPLC purification and evaluated in mouse brain, and the results were compared with those in the literature. Materials and Methods: $[^{18}F]1$ was prepared by $[^{18}F]$fluorination of the iodo precursor followed by acidic deprotection and then purified by HPLC. Tissue distribution studies were performed in mouse brain at the indicated time points and the result was expressed as %ID/g. Inhibition studies were also carried out with pretreatment of various ligands. Results: One HPLC purification method gave the desired product in 15-20% radiochemical yield and with high specific activity ($38-55GBq/{\mu}mol$). Tissue distribution studies showed that $[^{18}F]1$ specifically labeled nAChRs in mouse brain with a high thalamus to cerebellum uptake ratio (13.8 at 90 min). Inhibition studios demonstrated selective binding of $[^{18}F]1$ to nAChRs, blocking the uptake of the $[^{18}F]1$ in nAChR-rich legions by selective ligands such as cytisine and nicotine which are well-known nAChRs agonists. Conclusion: This study demonstrated that the $[^{18}F]1$ produced by the method using one HPLC purification gave the results similar to those reported in the literature. Therefore, this synthetic method can be readily applied to the routine preparation of $[^{18}F]1$, a PET radioligand for ${\alpha}_4{\beta}_2$ nAChRs imaging.

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF